Gas Filters

Sterilizing-grade gas filters protect biopharmaceutical products from contamination by microorganisms or particles during processes such as gas venting from tanks or bioreactors, compressed gas filtration and high-temperature or highly oxidizing applications. Non-sterilizing-grade filters reduce bioburden for non-critical applications or act as prefilters protecting a sterilizing-grade filter downstream.

 

Shop Gas Filters

 

Emflon II

Emflon® PFR

Emflon HTPFR

HDC II

Emflon PFA

Order Products

Product Use

Air, Gas, and Vent Filtration

SUPRAdisc SD II 150 200X150C440SP product photo

SUPRAdisc SD II 150 200X150C440SP

Product ID: 7007321
Unit of Measure
1/EA
Min Order Qty
1

This product is currently not available. Please contact us for more information.

Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 1700 cm² EFA, ½ in. hose barb connections, pre-sterilized by gamma irradiation product photo

Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 1700 cm² EFA, ½ in. hose barb connections, pre-sterilized by gamma irradiation

Product ID: KA3V002PV6S
Unit of Measure
1/EA
Min Order Qty
1
Membrane Material
Polyvinylidene fluoride (PVDF)
Effective Filtration Area (Metric)
1700 cm²
See All Attributes

This product is currently not available. Please contact us for more information.

Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 1700 cm² EFA, 1-1½ in. sanitary flange connections, pre-sterilized by gamma irradiation product photo

Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 1700 cm² EFA, 1-1½ in. sanitary flange connections, pre-sterilized by gamma irradiation

Product ID: KA3V002PV1S
Unit of Measure
1/EA
Min Order Qty
1
Membrane Material
Polyvinylidene fluoride (PVDF)
Effective Filtration Area (Metric)
1700 cm²
See All Attributes
Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 1700 cm² EFA, ½ in. hose barb connections, suitable for gamma irradiation product photo

Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 1700 cm² EFA, ½ in. hose barb connections, suitable for gamma irradiation

Product ID: KA3V002PV6G
Unit of Measure
1/EA
Min Order Qty
1
Membrane Material
Polyvinylidene fluoride (PVDF)
Effective Filtration Area (Metric)
1700 cm²
See All Attributes

SUPRAdisc SD II 300 200X300C232SPW

Product ID: 7007876
Unit of Measure
1/EA
Min Order Qty
1
1. Recommended Max. Backpressure During Backwash
0.5 bar
2. Recommended Max. Backpressure During Backwash
7.25 psid
Adaptor Type
Double Open End, Flat Gasket
Core Drainage Discs
Polypropylene
Diameter (Imperial)
12 in
Diameter (Metric)
287 mm
See All Attributes

SUPRAdisc SD II 100 200X100C232SPW

Product ID: 7007872
Unit of Measure
1/EA
Min Order Qty
1
1. Recommended Max. Backpressure During Backwash
0.5 bar
2. Recommended Max. Backpressure During Backwash
7.25 psid
Adaptor Type
Double Open End, Flat Gasket
Core Drainage Discs
Polypropylene
Diameter (Imperial)
12 in
Diameter (Metric)
287 mm
See All Attributes

Emflon® PFRW Filter Cartridge, AB1PFR8WH4

Product ID: AB1PFR8WH4
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
0.2 µm
Membrane Material
Double Layer PTFE
Effective Filtration Area (Metric cm²)
8000 cm²
Filter Cartridge Style
Code 8
Cartridge Length (Imperial)
10 in
Cartridge Length (Metric)
254 mm
See All Attributes

AB1UVI3EHF

Product ID: AB1UVI3EHF
Unit of Measure
1/EA
Min Order Qty
1

AB2P20018JDUP

Product ID: AB2P20018JDUP
Unit of Measure
1/EA
Min Order Qty
1
FEATURED

Emflon® PFRW Filter Cartridge, AB1PFR7WH4

Product ID: AB1PFR7WH4
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
0.2 µm
Membrane Material
Double Layer PTFE
Effective Filtration Area (Metric cm²)
8000 cm²
Filter Cartridge Style
Code 7
Cartridge Length (Imperial)
10 in
Cartridge Length (Metric)
254 mm
See All Attributes

Emflon® HTPFRW Filter Cartridges, AB3HTPFR7WH4

Product ID: AB3HTPFR7WH4
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
0.2 µm
Membrane Material
Double Layer PTFE
Effective Filtration Area (Metric cm²)
25200 cm²
Filter Cartridge Style
Code 7
Cartridge Length (Imperial)
30 in
Cartridge Length (Metric)
762 mm
See All Attributes

Profile® Star Filter Cartridge, AB3A0157WH4

Product ID: AB3A0157WH4
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
1.5 µm
Membrane Material
Polypropylene
Filter Cartridge Style
Code 7
Cartridge Length (Imperial)
30 in
Cartridge Length (Metric)
762 mm
Cartridge Length (Metric)
76.2 cm
See All Attributes

Description

Pall® Gas Filter Comparisons

 

Family/Grade

Emflon II 

Emflon PFR

Emflon HTPFR

HDCII

Emflon PFA

Membrane part number reference

V002

PFR

HTPFR

J

PFA

Membrane material

 

Polyvinyl fluoride (PVDF)

Polytetrafluoroethylene (PTFE)

Polytetrafluoroethylene (PTFE)

Polypropylene (PP)

Polytetrafluoroethylene (PTFE)

Support and drainage layer/ core/cage/endcap material

 

Polypropylene

 

Polypropylene

 

Polypropylene

 

Polypropylene

 

Polypropylene

Gamma Sterilizable?

Yes

No

No

No

No

Steam and Autoclave Sterilizable?

Yes

Yes

Yes

Yes

Yes

Pore size (µm)

0.2

0.2

0.2

1.2 – 10

0.2

Suitability for highly oxidative environments

 

Good

 

Very Good

 

Excellent

 

Good

 

Good

Suitability for high temperature environments

 

Good

 

Very Good

 

Excellent

 

Good

 

Good




For sterilizing-grade gas filtration in single-use systems

 

Emflon® II PVDF sterilizing-grade membrane gas filters are used in single-use systems and are validated for gamma irradiation. Emflon II filter capsules can be supplied either pre-sterilized by gamma irradiation or non-sterilized for sterilization by gamma irradiation/autoclave by the end user.

 

For sterilizing-grade gas filtration in stainless steel systems

 

Emflon® PFR PTFE sterilizing-grade membrane filter cartridges and capsules are used in nitrogen blanketing or compressed gas applications for stainless steel bioreactors and filling operations.  The hydrophobic and chemically inert filter membranes meet the FDA requirements for microbial removal to qualify as sterilizing-grade. These filters have high strength and long life under 60°C.

 

For high-temperature, ozonated-water venting and oxygen-enriched applications

 

Emflon® HTPFR PTFE sterilizing-grade membrane filter cartridges are specially designed for gas filtration in highly oxidizing applications such as oxygen enrichment of bioreactors, or process steps with temperatures above 60 °C, such as autoclaves, fermentation inlet air, aseptic packaging/ blow-fill-seal and WFI tank vents. The Emflon HTPFR cartridges have an oxidation-resistant structure that has been validated for extended use at elevated temperatures or in highly oxidizing applications.

 

Prefilter

 

HDC® II PP filters are used for prefiltration to protect sterilizing-grade filters.  They can also be used in fine particle applications where purity, reliability, and economy are critical.  All-polypropylene filter capsules and cartridges incorporate proprietary HDC II tapered pore polypropylene depth media and are available in a range of different formats. 

 

Bioburden

 

Emflon® PFA PTFE filters can be used in bioburden applications where a sterilizing-grade filter isn’t required.  These gas filter cartridges offer the highest levels of bioburden reduction, and high flow rates combined with a high filter area per 254 mm (10 in.) cartridge.

Applications

 

Application

Recommended Filter

Sterilizing-grade for single-use systems

Emflon® II

Sterilizing-grade for stainless steel systems

Emflon® PFR

Sterilizing-grade for high-temperature, ozonated-water venting, and oxygen enriched applications

Emflon® HTPFR

Prefilter for protection of sterilizing-grade gas filters

HDC® II

Bioburden reduction for high flow applications

Emflon® PFA

 


Need more help choosing the right filter? 

 

Our Scientific and Laboratory Services (SLS) team have been helping our customers optimize their processes for more than 50 years. Together with our wide range of filter membranes, we can find the right filtration solution or help to optimize your sterile filtration process. 

 

Contact us via the web form at the bottom of this page to request a consultation with one of our sterile filtration specialists to discuss your process and offer free support to help you get it right.

 

Documents

Application Notes

  • Safety Considerations for Gas Filtration in High-Temperature and Oxygen Enrichment Applications

    Select Language :
  • Best Practices For Successful Filter Integrity Testing Using The Water Intrusion Test (WIT) Method

    Select Language :
  • Identifying False Failures Using the Water Intrusion Test

    Select Language :
  • How to Select the Right Filter Integrity Test Instrument

    Select Language :
  • Sterile Vent Filtration on Ozonated Water Tanks

    Select Language :
  • Sterilizing Filtration of Enriched and Pure Gaseous Oxygen Employed in Cell Culture Applications

    Select Language :
  • Meeting Regulatory Requirements for Vent Filtration on Water For Injection (WFI) Tanks

    Select Language :