Gas Filters

Sterilizing-grade gas filters protect biopharmaceutical products from contamination by microorganisms or particles during processes such as gas venting from tanks or bioreactors, compressed gas filtration and high-temperature or highly oxidizing applications. Non-sterilizing-grade filters reduce bioburden for non-critical applications or act as prefilters protecting a sterilizing-grade filter downstream.

 

Shop Gas Filters

 

Emflon II

Emflon® PFR

Emflon HTPFR

HDC II

Emflon PFA

Order Products

Family

Ultipor

Anti Static

No

Beta Rating

BETA 1000

Ultipor Glass Fiber 25µm Nitrile Seal 26in 66.04cm length

Product ID: HC6500FDT26HYQ62
Unit of Measure
1/EA
Min Order Qty
1
Anti-Static
No
Beta Rating
BETA 1000
Element Series
HC6500
Family
Ultipor
Filter Media
Glass Fiber
Filter Removal Rating (μm)
25 µm
See All Attributes

Ultipor Glass Fiber 7µm Nitrile Seal 8in 20.32cm length

Product ID: HC7504FKN8H
Unit of Measure
1/EA
Min Order Qty
1
Anti-Static
No
Beta Rating
BETA 1000
Element Series
HC7504
Family
Ultipor
Filter Media
Glass Fiber
Filter Removal Rating (μm)
7 µm
See All Attributes

Ultipor Glass Fiber 7µm Fluorocarbon Seal 8in 20.32cm length

Product ID: HC8904FKN8Z
Unit of Measure
12/EA
Min Order Qty
12
Anti-Static
No
Beta Rating
BETA 1000
Element Series
HC8904
Family
Ultipor
Filter Media
Glass Fiber
Filter Removal Rating (μm)
7 µm
See All Attributes

Ultipor Glass Fiber 7µm Nitrile Seal 4in 10.16cm length

Product ID: HC9020FKN4HYQ62
Unit of Measure
10/EA
Min Order Qty
10
Anti-Static
No
Beta Rating
BETA 1000
Element Series
HC9020
Family
Ultipor
Filter Media
Glass Fiber
Filter Removal Rating (μm)
7 µm
See All Attributes

Ultipor Glass Fiber 12µm Nitrile Seal 13in 33.02cm length

Product ID: HC9600FKS13HYQ62
Unit of Measure
3/EA
Min Order Qty
3
Anti-Static
No
Beta Rating
BETA 1000
Element Series
HC9600
Family
Ultipor
Filter Media
Glass Fiber
Filter Removal Rating (μm)
12 µm
See All Attributes

Ultipor Glass Fiber 12µm Nitrile Seal 16in 40.64cm length

Product ID: HC9606FDS16H
Unit of Measure
1/EA
Min Order Qty
1
Anti-Static
No
Beta Rating
BETA 1000
Element Series
HC9606
Family
Ultipor
Filter Media
Glass Fiber
Filter Removal Rating (μm)
12 µm
See All Attributes

Ultipor Glass Fiber 7µm Nitrile Seal 5in 12.7cm length

Product ID: HC9730FKN5H
Unit of Measure
8/EA
Min Order Qty
8
Anti-Static
No
Beta Rating
BETA 1000
Element Series
HC9730
Family
Ultipor
Filter Media
Glass Fiber
Filter Removal Rating (μm)
7 µm
See All Attributes

Ultipor Glass Fiber 5µm Nitrile Seal 10in 25.4cm length

Product ID: HC9730FKP10H
Unit of Measure
4/EA
Min Order Qty
4
Anti-Static
No
Beta Rating
BETA 1000
Element Series
HC9730
Family
Ultipor
Filter Media
Glass Fiber
Filter Removal Rating (μm)
5 µm
See All Attributes

Ultipor Glass Fiber 5µm Nitrile Seal 27in 68.58cm length

Product ID: HC9735FKP27H
Unit of Measure
1/EA
Min Order Qty
1
Anti-Static
No
Beta Rating
BETA 1000
Element Series
HC9735
Family
Ultipor
Filter Media
Glass Fiber
Filter Removal Rating (μm)
5 µm
See All Attributes

Ultipor Glass Fiber 5µm Fluorocarbon Seal 18in 45.72cm length

Product ID: HC9735FKP18Z
Unit of Measure
3/EA
Min Order Qty
3
Anti-Static
No
Beta Rating
BETA 1000
Element Series
HC9735
Family
Ultipor
Filter Media
Glass Fiber
Filter Removal Rating (μm)
5 µm
See All Attributes

Ultipor Glass Fiber 7µm Nitrile Seal 18in 45.72cm length

Product ID: HC0101FKN18HY533
Unit of Measure
6/EA
Min Order Qty
6
Anti-Static
No
Beta Rating
BETA 1000
Element Series
HC0101
Family
Ultipor
Filter Media
Glass Fiber
Filter Removal Rating
7 micron, Beta 1000
See All Attributes

Ultipor Glass Fiber 3µm Nitrile Seal 36in 91.44cm length

Product ID: HC0101FKZ36H
Unit of Measure
1/EA
Min Order Qty
1
Anti-Static
No
Beta Rating
BETA 1000
Element Series
HC0101
Family
Ultipor
Filter Media
Glass Fiber
Filter Removal Rating (μm)
3 µm
See All Attributes

Description

Pall® Gas Filter Comparisons

 

Family/Grade

Emflon II 

Emflon PFR

Emflon HTPFR

HDCII

Emflon PFA

Membrane part number reference

V002

PFR

HTPFR

J

PFA

Membrane material

 

Polyvinyl fluoride (PVDF)

Polytetrafluoroethylene (PTFE)

Polytetrafluoroethylene (PTFE)

Polypropylene (PP)

Polytetrafluoroethylene (PTFE)

Support and drainage layer/ core/cage/endcap material

 

Polypropylene

 

Polypropylene

 

Polypropylene

 

Polypropylene

 

Polypropylene

Gamma Sterilizable?

Yes

No

No

No

No

Steam and Autoclave Sterilizable?

Yes

Yes

Yes

Yes

Yes

Pore size (µm)

0.2

0.2

0.2

1.2 – 10

0.2

Suitability for highly oxidative environments

 

Good

 

Very Good

 

Excellent

 

Good

 

Good

Suitability for high temperature environments

 

Good

 

Very Good

 

Excellent

 

Good

 

Good




For sterilizing-grade gas filtration in single-use systems

 

Emflon® II PVDF sterilizing-grade membrane gas filters are used in single-use systems and are validated for gamma irradiation. Emflon II filter capsules can be supplied either pre-sterilized by gamma irradiation or non-sterilized for sterilization by gamma irradiation/autoclave by the end user.

 

For sterilizing-grade gas filtration in stainless steel systems

 

Emflon® PFR PTFE sterilizing-grade membrane filter cartridges and capsules are used in nitrogen blanketing or compressed gas applications for stainless steel bioreactors and filling operations.  The hydrophobic and chemically inert filter membranes meet the FDA requirements for microbial removal to qualify as sterilizing-grade. These filters have high strength and long life under 60°C.

 

For high-temperature, ozonated-water venting and oxygen-enriched applications

 

Emflon® HTPFR PTFE sterilizing-grade membrane filter cartridges are specially designed for gas filtration in highly oxidizing applications such as oxygen enrichment of bioreactors, or process steps with temperatures above 60 °C, such as autoclaves, fermentation inlet air, aseptic packaging/ blow-fill-seal and WFI tank vents. The Emflon HTPFR cartridges have an oxidation-resistant structure that has been validated for extended use at elevated temperatures or in highly oxidizing applications.

 

Prefilter

 

HDC® II PP filters are used for prefiltration to protect sterilizing-grade filters.  They can also be used in fine particle applications where purity, reliability, and economy are critical.  All-polypropylene filter capsules and cartridges incorporate proprietary HDC II tapered pore polypropylene depth media and are available in a range of different formats. 

 

Bioburden

 

Emflon® PFA PTFE filters can be used in bioburden applications where a sterilizing-grade filter isn’t required.  These gas filter cartridges offer the highest levels of bioburden reduction, and high flow rates combined with a high filter area per 254 mm (10 in.) cartridge.

Applications

 

Application

Recommended Filter

Sterilizing-grade for single-use systems

Emflon® II

Sterilizing-grade for stainless steel systems

Emflon® PFR

Sterilizing-grade for high-temperature, ozonated-water venting, and oxygen enriched applications

Emflon® HTPFR

Prefilter for protection of sterilizing-grade gas filters

HDC® II

Bioburden reduction for high flow applications

Emflon® PFA

 


Need more help choosing the right filter? 

 

Our Scientific and Laboratory Services (SLS) team have been helping our customers optimize their processes for more than 50 years. Together with our wide range of filter membranes, we can find the right filtration solution or help to optimize your sterile filtration process. 

 

Contact us via the web form at the bottom of this page to request a consultation with one of our sterile filtration specialists to discuss your process and offer free support to help you get it right.

 

Documents

Application Notes

  • Safety Considerations for Gas Filtration in High-Temperature and Oxygen Enrichment Applications

    Select Language :
  • Best Practices For Successful Filter Integrity Testing Using The Water Intrusion Test (WIT) Method

    Select Language :
  • Identifying False Failures Using the Water Intrusion Test

    Select Language :
  • How to Select the Right Filter Integrity Test Instrument

    Select Language :
  • Sterile Vent Filtration on Ozonated Water Tanks

    Select Language :
  • Sterilizing Filtration of Enriched and Pure Gaseous Oxygen Employed in Cell Culture Applications

    Select Language :
  • Meeting Regulatory Requirements for Vent Filtration on Water For Injection (WFI) Tanks

    Select Language :