Filter Capsules

Pall has a wide range of filter capsule products.

Order Products

Membrane Material

Regenerated Cellulose

Supracap 50 depth filter capsules are designed for developing and optimizing a process during scale-up and scale-down studies. They can be used to quickly and accurately determine which series and grade of depth filter media will provide the best performance as well as the necessary filtration area required to meet process volume

27 Products In Family

Supracap™ 50 depth filter capsule with dual-layer media grade PDD1 (0.1-0.85 µm retention rating) and luer-lock connections product photo

Supracap™ 50 depth filter capsule with dual-layer media grade PDD1 (0.1-0.85 µm retention rating) and luer-lock connections

Product ID: SC050PDD1
Unit of Measure
1/EA
Min Order Qty
1
Retention Rating
0.1-0.85 µm
Membrane Material
Regenerated Cellulose
Maximum Batch Volume
3 L
Effective Filtration Area (Metric)
22 cm²
See All Attributes
Supracap™ 50 depth filter capsule with dual-layer media grade PDP8 (6-30 µm retention rating) and luer-lock connections product photo

Supracap™ 50 depth filter capsule with dual-layer media grade PDP8 (6-30 µm retention rating) and luer-lock connections

Product ID: SC050PDP8
Unit of Measure
1/EA
Min Order Qty
1
Retention Rating
6-30 µm
Membrane Material
Regenerated Cellulose
Maximum Batch Volume
3 L
Effective Filtration Area (Metric)
22 cm²
See All Attributes
Supracap™ 50 depth filter capsule with activated carbon type AKS4 (typical target contaminant molecular weight 400-1500 Da) and luer-lock connections product photo

Supracap™ 50 depth filter capsule with activated carbon type AKS4 (typical target contaminant molecular weight 400-1500 Da) and luer-lock connections

Product ID: SC050XAK4
Unit of Measure
1/EA
Min Order Qty
1
Membrane Material
Regenerated Cellulose
Maximum Batch Volume
3 L
Effective Filtration Area (Metric)
22 cm²
See All Attributes
Supracap™ 50 depth filter capsule with dual-layer media grade PDD2 (0.2-0.8 µm retention rating) and luer-lock connections product photo

Supracap™ 50 depth filter capsule with dual-layer media grade PDD2 (0.2-0.8 µm retention rating) and luer-lock connections

Product ID: SC050PDD2
Unit of Measure
1/EA
Min Order Qty
1
Retention Rating
0.2-0.8 µm
Membrane Material
Regenerated Cellulose
Maximum Batch Volume
3 L
Effective Filtration Area (Metric)
22 cm²
See All Attributes
Supracap™ 50 depth filter capsule with activated carbon type AKS5 (typical target contaminant molecular weight 200-400 Da) and luer-lock connections product photo

Supracap™ 50 depth filter capsule with activated carbon type AKS5 (typical target contaminant molecular weight 200-400 Da) and luer-lock connections

Product ID: SC050XAK5
Unit of Measure
1/EA
Min Order Qty
1
Membrane Material
Regenerated Cellulose
Maximum Batch Volume
3 L
Effective Filtration Area (Metric)
22 cm²
See All Attributes
Supracap™ 50 depth filter capsule with single-layer media grade SUPRA 80P (1-3 µm retention rating) and luer-lock connections product photo

Supracap™ 50 depth filter capsule with single-layer media grade SUPRA 80P (1-3 µm retention rating) and luer-lock connections

Product ID: SC050P080
Unit of Measure
1/EA
Min Order Qty
1
Retention Rating
1-3 µm
Membrane Material
Regenerated Cellulose
Maximum Batch Volume
3 L
Effective Filtration Area (Metric)
22 cm²
See All Attributes
Supracap™ 50 depth filter capsule with dual-layer media grade PDK5 (1.5-20 µm retention rating) and luer-lock connections product photo

Supracap™ 50 depth filter capsule with dual-layer media grade PDK5 (1.5-20 µm retention rating) and luer-lock connections

Product ID: SC050PDK5
Unit of Measure
1/EA
Min Order Qty
1
Retention Rating
1.5-20 µm
Membrane Material
Regenerated Cellulose
Maximum Batch Volume
3 L
Effective Filtration Area (Metric)
22 cm²
See All Attributes
Supracap™ 50 depth filter capsule with activated carbon type AKS6 (typical target contaminant molecular weight 400-1500 Da) and luer-lock connections product photo

Supracap™ 50 depth filter capsule with activated carbon type AKS6 (typical target contaminant molecular weight 400-1500 Da) and luer-lock connections

Product ID: SC050XAK6
Unit of Measure
1/EA
Min Order Qty
1
Membrane Material
Regenerated Cellulose
Maximum Batch Volume
3 L
Effective Filtration Area (Metric)
22 cm²
See All Attributes
Supracap™ 50 depth filter capsule with single-layer media grade K100P (1-3 µm retention rating) and luer-lock connections product photo

Supracap™ 50 depth filter capsule with single-layer media grade K100P (1-3 µm retention rating) and luer-lock connections

Product ID: SC050P100
Unit of Measure
1/EA
Min Order Qty
1
Retention Rating
1-3 µm
Membrane Material
Regenerated Cellulose
Maximum Batch Volume
3 L
Effective Filtration Area (Metric)
22 cm²
See All Attributes
Supracap™ 50 depth filter capsule with activated carbon type AKS1 (typical target contaminant molecular weight 400-1500 Da) and luer-lock connections product photo

Supracap™ 50 depth filter capsule with activated carbon type AKS1 (typical target contaminant molecular weight 400-1500 Da) and luer-lock connections

Product ID: SC050XAK1
Unit of Measure
1/EA
Min Order Qty
1
Membrane Material
Regenerated Cellulose
Maximum Batch Volume
3 L
Effective Filtration Area (Metric)
22 cm²
See All Attributes
Supracap™ 50 depth filter capsule with single-layer media grade T1500P (11-30 µm retention rating) and luer-lock connections product photo

Supracap™ 50 depth filter capsule with single-layer media grade T1500P (11-30 µm retention rating) and luer-lock connections

Product ID: SC050P1500
Unit of Measure
1/EA
Min Order Qty
1
Retention Rating
11-30 µm
Membrane Material
Regenerated Cellulose
Maximum Batch Volume
3 L
Effective Filtration Area (Metric)
22 cm²
See All Attributes