Oenoclear™ II Pleated Filter Cartridges

A Regenerable Filtration Solution for Wine Pre-filtration Purposes

Oenoclear II pleated filter media is constructed from a unique liquid crystal polymer specifically noted for its thermal stability, high mechanical strength and good chemical compatibility. When configured into single open-ended (SOE) AB style cartridges, the resulting filter allows for repeated regeneration and sanitization in situ for long service life. 

Order Products

Brand

Nexis®

Cartridge Length (Metric)

102 mm

Nexis® A Series Filter Cartridges, Removal Rating 0.5 μm, Polypropylene, Length 4 inches

Product ID: NXA054UM3S
Unit of Measure
30/EA
Min Order Qty
30
Removal Rating
0.5 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
4 in
Cartridge Length (Metric)
102 mm
Cartridge Length (Metric)
10.2 cm
Gasket / O-Ring Material
Silicone
See All Attributes

Nexis® A Series Filter Cartridges, Removal Rating 10 μm, Polypropylene, Length 4 inches

Product ID: NXA104U
Unit of Measure
30/EA
Min Order Qty
30
Removal Rating
10 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
4 in
Cartridge Length (Metric)
102 mm
Cartridge Length (Metric)
10.2 cm
Gasket / O-Ring Material
NA
See All Attributes

Nexis® A Series Filter Cartridges, Removal Rating 10 μm, Polypropylene, Length 4 inches, EPDM

Product ID: NXA104UM3E
Unit of Measure
30/EA
Min Order Qty
30
Removal Rating
10 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
4 in
Cartridge Length (Metric)
102 mm
Cartridge Length (Metric)
10.2 cm
Gasket / O-Ring Material
EPDM
See All Attributes

This product is currently not available. Please contact us for more information.

Nexis® A Series Filter Cartridges, Removal Rating 120 μm, Polypropylene, Length 4 inches

Product ID: NXA1204U
Unit of Measure
60/EA
Min Order Qty
60
Removal Rating
120 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
4 in
Cartridge Length (Metric)
102 mm
Cartridge Length (Metric)
10.2 cm
Gasket / O-Ring Material
NA
See All Attributes

Nexis® A Series Filter Cartridges, Removal Rating 1 μm, Polypropylene, Length 4 inches

Product ID: NXA14UM3E
Unit of Measure
30/EA
Min Order Qty
30
Removal Rating
1 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
4 in
Cartridge Length (Metric)
102 mm
Cartridge Length (Metric)
10.2 cm
Gasket / O-Ring Material
EPDM
See All Attributes
NXA 1-4U-M3S product photo

Nexis, NXA, 1 μm, 10.2 cm (4 in), SOE flat closed end, external 222 O-rings (retrofits other manufacturers’ Code 0), Silicone gasket

Product ID: NXA14UM3S
Unit of Measure
1/EA
Min Order Qty
1
Micron
1 micron
NXA 20-4U-M3E product photo

Nexis, NXA, 20 μm, 10.2 cm (4 in), SOE flat closed end, external 222 O-rings (retrofits other manufacturers’ Code 0), EPDM gasket

Product ID: NXA204UM3E
Unit of Measure
30/EA
Min Order Qty
30
Micron
20 micron

Nexis® A Series Filter Cartridges, Removal Rating 50 μm, Polypropylene, Length 4 inches

Product ID: NXA504U
Unit of Measure
30/EA
Min Order Qty
30
Removal Rating
50 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
4 in
Cartridge Length (Metric)
102 mm
Cartridge Length (Metric)
10.2 cm
Gasket / O-Ring Material
NA
See All Attributes

Nexis® A Series Filter Cartridges, Removal Rating 90 μm, Polypropylene, Length 4 inches

Product ID: NXA904U
Unit of Measure
120/EA
Min Order Qty
120
Removal Rating
90 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
4 in
Cartridge Length (Metric)
102 mm
Cartridge Length (Metric)
10.2 cm
Gasket / O-Ring Material
NA
See All Attributes

Nexis® T Filter Cartridges, Removal Rating 10 μm, Polypropylene, Length 4 inches

Product ID: NXT104U
Unit of Measure
120/EA
Min Order Qty
120
Removal Rating
10 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
4 in
Cartridge Length (Metric)
102 mm
Cartridge Length (Metric)
10.2 cm
Gasket / O-Ring Material
NA
See All Attributes
NXT 1-4U product photo

Nexis, NXT, 1 μm, 10.2 cm (4 in), DOE industrial (no end caps)

Product ID: NXT14U
Unit of Measure
1/EA
Min Order Qty
1
Micron
1 micron

Nexis® T Filter Cartridges, Removal Rating 200 μm, Polypropylene, Length 4 inches

Product ID: NXT2004U
Unit of Measure
30/EA
Min Order Qty
60
Removal Rating
200 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
4 in
Cartridge Length (Metric)
102 mm
Cartridge Length (Metric)
10.2 cm
Gasket / O-Ring Material
NA
See All Attributes

Description

Why choose Oenoclear II pleated filter cartridges?

The dense polymer matrix provides excellent yeast and colloid reduction making it ideal for wine tanker filling, final polish filtration in the cellar and protection of downstream membrane filters. When combined, the long service life and high removal efficiency enable low operating costs, especially when compared to traditional sterilizing grade sheet filters.

 

Additional benefits include: 

 

  • Fixed pore structure 
  • Wide range of chemical compatibility
  • Capability to switch between red and white wine

Applications

Food and Beverage:

Prefiltration

Wine, cider

Specifications

 

Food Contact Compliance

 

  • Food contact compliant filters are available. Please consult the Declarations of Compliance for applicable part numbers at the links below.
  • Please refer to the Pall website for a Declaration of Compliance to specific National Legislation and/or Regional Regulatory requirements for food contact use.

 

Quality
 
  • Cartridges produced in a controlled environment 
  • Manufactured according to ISO 9001:2015 certified Quality Management System

 

Liquid Removal Rating1
 
  • Liquid removal rating: 0.8 micron @ 99.98 % efficiency (β5000)

 

Operating Characteristics in Compatible Fluids2
Maximum Differential Pressure Operating Temperature
5.5 bard (80 psid) (forward) 50 °C (122 °F)
4.1 bard (60 psid) (forward) 80 °C (176 °F)
500 mbard (7 psid) (reverse) 20 °C (68 °F)

 

Sterilization and Sanitization

Media Temperature Cumulative Time3
Steam 121 °C (250 °F) 25 hours
Hot Water 90 °C (194 °F) 50 hours
Peroxyacetic acid based sanitizer (300 ppm total peroxides) 20 °C (68 °F) 50 hours

 

Typical Flow Rates4

 

 

1The Oenoclear II Filter Cartridge liquid retention rating is based on modified OSU-F2 test.


2Compatible fluids are defined as those which do not swell, soften or attack any of the filter components.


3Measured under laboratory test conditions. The actual cumulative time depends on the process conditions. Pall recommends the use of Code 7 adaptors to ensure filter sealing after cooling. Cartridges should be cooled to system operating temperature prior to use. Contact Pall for recommended procedures.


4Typical initial clean media ΔP 254 mm (10”) cartridge for water at 20 °C (68 °F); viscosity 1 centipoise. For 508 mm, 762 mm and 1016 mm configurations divide the differential pressure by 2, 3, and 4 respectively.

Documents

Data Sheets

  • Oenoclear™ II Filter Cartridges

    Select Language :