Claris® Polypropylene Depth Filter Cartridges

For Consistent, Reliable Filtration at an Economical Cost

Claris melt blown depth filter cartridges offer coarser ratings for primary or pre-filtration applications and higher fluid flow applications where cleanliness levels are not specified. When used in industrial applications, these spunbond depth filter cartridges are for general particulate reduction and less sensitive component protection at temperatures less than 60 °C (140°F).

Order Products

Format

Kleenpak

HDC® II membrane in Kleenpak™ capsule, 0.6 µm removal rating, 1000 cm² EFA, 1½ in sanitary flange inlet and ¼-½ in outlet connections product photo
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
0.6 µm
See All Attributes
Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 1700 cm² EFA, ½ in. hose barb connections, pre-sterilized by gamma irradiation product photo

Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 1700 cm² EFA, ½ in. hose barb connections, pre-sterilized by gamma irradiation

Product ID: KA3V002PV6S
Unit of Measure
1/EA
Min Order Qty
1
Membrane Material
Polyvinylidene fluoride (PVDF)
Effective Filtration Area (Metric)
1700 cm²
See All Attributes

This product is currently not available. Please contact us for more information.

Fluorodyne® II DFL membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 1500 cm² EFA, 1-1½ in. sanitary flange connections, suitable for gamma irradiation product photo

Fluorodyne® II DFL membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 1500 cm² EFA, 1-1½ in. sanitary flange connections, suitable for gamma irradiation

Product ID: KA3DFLP1G
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
0.2 µm
Membrane Material
Polyvinylidene fluoride (PVDF)
Sterilization Option(s)
Suitable for Gamma Irradiation, Suitable for Autoclave
See All Attributes
Supor® EKV membrane in Kleenpak™ capsule, 0.2 µm removal rating, 375 cm² EFA, 1-1½ in. sanitary flange connections, suitable for gamma irradiation product photo

Supor® EKV membrane in Kleenpak™ capsule, 0.2 µm removal rating, 375 cm² EFA, 1-1½ in. sanitary flange connections, suitable for gamma irradiation

Product ID: KA1EKVP1G
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
0.2 µm
Membrane Material
Polyethersulfone (PES)
Effective Filtration Area
375 cm²
Sterilization Option(s)
Suitable for Gamma Irradiation, Suitable for Autoclave
Inlet Connection
1-1½ in (25-38 mm) sanitary flange
See All Attributes

This product is currently not available. Please contact us for more information.

Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 1700 cm² EFA, 1-1½ in. sanitary flange connections, pre-sterilized by gamma irradiation product photo

Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 1700 cm² EFA, 1-1½ in. sanitary flange connections, pre-sterilized by gamma irradiation

Product ID: KA3V002PV1S
Unit of Measure
1/EA
Min Order Qty
1
Membrane Material
Polyvinylidene fluoride (PVDF)
Effective Filtration Area (Metric)
1700 cm²
See All Attributes
Supor® EKV membrane in Kleenpak™ capsule, 0.2 µm removal rating, 1500 cm² EFA, ½ in. hose barb connections, suitable for gamma irradiation product photo

Supor® EKV membrane in Kleenpak™ capsule, 0.2 µm removal rating, 1500 cm² EFA, ½ in. hose barb connections, suitable for gamma irradiation

Product ID: KA3EKVP6G
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
0.2 µm
Membrane Material
Polyethersulfone (PES)
Effective Filtration Area
1500 cm²
Sterilization Option(s)
Suitable for Gamma Irradiation, Suitable for Autoclave
Inlet Connection
½ in (13 mm) hose barb
See All Attributes
Supor® EKV membrane in Kleenpak™ capsule, 0.2 µm removal rating, 1500 cm² EFA, ½ in. hose barb connections, pre-sterilized by gamma irradiation product photo

Supor® EKV membrane in Kleenpak™ capsule, 0.2 µm removal rating, 1500 cm² EFA, ½ in. hose barb connections, pre-sterilized by gamma irradiation

Product ID: KA3EKVP6S
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
0.2 µm
Membrane Material
Polyethersulfone (PES)
Effective Filtration Area
1500 cm²
Sterilization Option(s)
Provided Pre-Sterilized by Gamma Irradiation
Inlet Connection
½ in (13 mm) hose barb
See All Attributes
Fluorodyne® II DFL membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 800 cm² EFA, 1½ in. sanitary flange inlet and ½ in. hose barb outlet connections, pre-sterilized by gamma irradiation product photo

Fluorodyne® II DFL membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 800 cm² EFA, 1½ in. sanitary flange inlet and ½ in. hose barb outlet connections, pre-sterilized by gamma irradiation

Product ID: KA2DFLP16S
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
0.2 µm
Membrane Material
Polyvinylidene fluoride (PVDF)
Sterilization Option(s)
Provided Pre-Sterilized by Gamma Irradiation
See All Attributes

This product is currently not available. Please contact us for more information.

Supor® EKV membrane in Kleenpak™ capsule, 0.2 µm removal rating, 375 cm² EFA, 1-1½ in. sanitary flange connections, pre-sterilized by gamma irradiation product photo

Supor® EKV membrane in Kleenpak™ capsule, 0.2 µm removal rating, 375 cm² EFA, 1-1½ in. sanitary flange connections, pre-sterilized by gamma irradiation

Product ID: KA1EKVP1S
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
0.2 µm
Membrane Material
Polyethersulfone (PES)
Effective Filtration Area
375 cm²
Sterilization Option(s)
Provided Pre-Sterilized by Gamma Irradiation
Inlet Connection
1-1½ in (25-38 mm) sanitary flange
See All Attributes

This product is currently not available. Please contact us for more information.

HDC® II membrane in Kleenpak™ capsule, 4.5 µm removal rating, 600 cm² EFA, 1½ in sanitary flange inlet and ¼-½ in outlet connections product photo
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
4.5 µm
See All Attributes
HDC® II membrane in Kleenpak™ capsule, 1.2 µm removal rating, 600 cm² EFA, 1½ in sanitary flange inlet and ¼-½ in outlet connections product photo
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
1.2 µm
See All Attributes
Supor® EKV membrane in Kleenpak™ capsule, 0.2 µm removal rating, 750 cm² EFA, 1-1½ in. sanitary flange connections, pre-sterilized by gamma irradiation product photo

Supor® EKV membrane in Kleenpak™ capsule, 0.2 µm removal rating, 750 cm² EFA, 1-1½ in. sanitary flange connections, pre-sterilized by gamma irradiation

Product ID: KA2EKVP1S
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
0.2 µm
Membrane Material
Polyethersulfone (PES)
Effective Filtration Area
750 cm²
Sterilization Option(s)
Provided Pre-Sterilized by Gamma Irradiation
Inlet Connection
1-1½ in (25-38 mm) sanitary flange
See All Attributes

This product is currently not available. Please contact us for more information.

Description

Why choose Claris depth filter cartridges?

These cartridges are an economical option to achieve consistent filter performance, reliability and strength (alternative to molded cores) without compromising filter integrity or media depth.

 

Additional benefits include:

 

  • Easy and safe cartridge incineration and disposal
  • Capable of coarser ratings
  • No surfactants, binders, anti-static agents, or adhesives

Product Highlights:

  • The most economical melt blown depth filter cartridge
  • All polypropylene construction
  • Long service life
  • Produced according to quality ISO standards
  • Various assembly end configurations are available to match housing internals 

Applications

Chemicals and Polymers

  • Chemicals – Intermediate product (other), raw material (gas, air, liquid) and final product (liquid)
  • Petrochemicals – Amine, Benfield and other solvent loops

Food and Beverage

  • Bottled Water – Incoming water primary filtration, particulate control and pre-RO filtration
  • Soft Drinks – Incoming water primary filtration, particulate control and pre- RO filtration
  • Beer (corporate)– Particle filtration
  • Juice – Water filtration

Oil and Gas

  • Upstream – Injection water and SRU
  • Midstream – LNG acid gas, acid gas, glycol filtration and process water
  • Refinery – Amine systems

Microelectronics

  • Photovoltaics – Waste reclaim and wet etch and cleans

Power and Utilities

  • Combined Cycle Plants – Turbine lubrication

Industrial Manufacturing

  • Automotive – Filling lines/filling stations, parts washing, pre-treatment and e-coat, sealant, paint and coatings, stamping and test stands
  • Mining Equipment – Fuel filtration (on and off-board), gear case, hydraulic fluid, lube oil (on and off-board), final product (post smelt/burn off impurities), slurry, wastewater and rinsing water

Specifications

Documents

Data Sheet

  • Claris Filter Cartridges for General Purpose Particle Reduction

    Select Language :
  • 1251-10C - Claris® Series Filter Cartridges

    Select Language :