Profile® II Ink Jet Depth Filter Cartridges

For Pre and Final Filtration of Ink Jet Inks

Profile II Ink Jet depth filter cartridges are constructed from all-polypropylene components with ethylene-propylene O-rings. These absolute-rated depth filter cartridges have excellent compatibility with most ink systems where removal ratings from 0.3 to 10 µm are required. In addition, proven tapered-pore technology and a sanitary dual O-ring seal assure filter integrity and ease of use with a wide range of ink jet formulations.

Order Products

Brand

DFT Classic®

DFT Classic®, Filter Cartridges, Removal Rating 1 μm, Length 20 Inches, 304 stainless steel, with Core Cover

Product ID: C001AW20AC
Unit of Measure
10/EA
Min Order Qty
10
Removal Rating
1 µm
Cartridge Length (Imperial)
20 in
Cartridge Length (Metric)
508 mm
Cartridge Length (Metric)
50.8 cm
Cartridge Outer Diameter (OD) (Imperial)
2.5 in
Cartridge Outer Diameter (OD) (Metric)
6.4 cm
See All Attributes

DFT Classic®, Filter Cartridges, Removal Rating 1 μm, Length 20 Inches, Polypropylene

Product ID: C001AW20U1PK
Unit of Measure
10/EA
Min Order Qty
10
Removal Rating
1 µm
Cartridge Length (Imperial)
20 in
Cartridge Length (Metric)
508 mm
Cartridge Length (Metric)
50.8 cm
Cartridge Outer Diameter (OD) (Imperial)
2.5 in
Cartridge Outer Diameter (OD) (Metric)
6.4 cm
See All Attributes
DFT Classic®, Filter Cartridges, Removal Rating 1 μm, Length 30 Inches, 304 stainless steel product photo

DFT Classic®, Filter Cartridges, Removal Rating 1 μm, Length 30 Inches, 304 stainless steel

Product ID: C001AW30A
Unit of Measure
1/EA
Min Order Qty
1

DFT Classic®, Filter Cartridges, Removal Rating 5 μm, Length 19.5 Inches, 304 stainless steel, Bulk packaging

Product ID: C005AW195A
Unit of Measure
10/EA
Min Order Qty
10
Removal Rating
5 µm
Cartridge Length (Imperial)
19.5 in
Cartridge Length (Metric)
495 mm
Cartridge Length (Metric)
49.5 cm
Cartridge Outer Diameter (OD) (Imperial)
2.5 in
Cartridge Outer Diameter (OD) (Metric)
6.4 cm
See All Attributes

DFT Classic®, Filter Cartridges, Removal Rating 5 μm, Length 20 Inches, 316 stainless steel, with Core Cover

Product ID: C005AW20SC
Unit of Measure
10/EA
Min Order Qty
10
Removal Rating
5 µm
Cartridge Length (Imperial)
20 in
Cartridge Length (Metric)
508 mm
Cartridge Length (Metric)
50.8 cm
Cartridge Outer Diameter (OD) (Imperial)
2.5 in
Cartridge Outer Diameter (OD) (Metric)
6.4 cm
See All Attributes

DFT Classic®, Filter Cartridges, Removal Rating 5 μm, Length 20 Inches, 304 stainless steel, with Core Cover

Product ID: C005AW20AC
Unit of Measure
10/EA
Min Order Qty
10
Removal Rating
5 µm
Cartridge Length (Imperial)
20 in
Cartridge Length (Metric)
508 mm
Cartridge Length (Metric)
50.8 cm
Cartridge Outer Diameter (OD) (Imperial)
2.5 in
Cartridge Outer Diameter (OD) (Metric)
6.4 cm
See All Attributes

DFT Classic®, Filter Cartridges, Removal Rating 5 μm, Length 20 Inches, 316 stainless steel, Individually wrapped

Product ID: C005AW20S1PK
Unit of Measure
10/EA
Min Order Qty
10
Removal Rating
5 µm
Cartridge Length (Imperial)
20 in
Cartridge Length (Metric)
508 mm
Cartridge Length (Metric)
50.8 cm
Cartridge Outer Diameter (OD) (Imperial)
2.5 in
Cartridge Outer Diameter (OD) (Metric)
6.4 cm
See All Attributes

DFT Classic®, Filter Cartridges, Removal Rating 5 μm, Length 40 Inches, 304 stainless steel, with Core Cover

Product ID: C005AW40AC
Unit of Measure
10/EA
Min Order Qty
10
Removal Rating
5 µm
Cartridge Length (Imperial)
40 in
Cartridge Length (Metric)
1016 mm
Cartridge Length (Metric)
101.6 cm
Cartridge Outer Diameter (OD) (Imperial)
2.5 in
Cartridge Outer Diameter (OD) (Metric)
6.4 cm
See All Attributes

DFT Classic®, Filter Cartridges, Removal Rating 10 μm, Length 40 Inches, Polypropylene, Bulk packaging

Product ID: C010AW40U
Unit of Measure
10/EA
Min Order Qty
10
Removal Rating
10 µm
Cartridge Length (Imperial)
40 in
Cartridge Length (Metric)
1016 mm
Cartridge Length (Metric)
101.6 cm
Cartridge Outer Diameter (OD) (Imperial)
2.5 in
Cartridge Outer Diameter (OD) (Metric)
6.4 cm
See All Attributes

DFT Classic®, Filter Cartridges, Removal Rating 30 μm, Length 10 Inches, 304 stainless steel

Product ID: C030A10A
Unit of Measure
30/EA
Min Order Qty
30
Removal Rating
30 µm
Cartridge Length (Imperial)
10 in
Cartridge Length (Metric)
254 mm
Cartridge Length (Metric)
25.4 cm
Cartridge Outer Diameter (OD) (Imperial)
2.5 in
Cartridge Outer Diameter (OD) (Metric)
6.4 cm
See All Attributes

DFT Classic®, Filter Cartridges, Removal Rating 75 μm, Length 30 Inches, Polypropylene

Product ID: C075AW30U
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
75 µm
Cartridge Length (Imperial)
30 in
Cartridge Length (Metric)
762 mm
Cartridge Length (Metric)
76.2 cm
Cartridge Outer Diameter (OD) (Imperial)
2.5 in
Cartridge Outer Diameter (OD) (Metric)
6.4 cm
See All Attributes
DFT Classic®, Filter Cartridges, Removal Rating 100 μm, Length 10 Inches, Polypropylene product photo

DFT Classic®, Filter Cartridges, Removal Rating 100 μm, Length 10 Inches, Polypropylene

Product ID: C100A10U
Unit of Measure
30/EA
Min Order Qty
30

Description

Why choose Profile II ink jet depth filter cartridges?

A graded pore density means these ink filters provide longer service life and reduce the filtration cost per gallon/liter.

 

Additional benefits include:

 

  • Provide consistent from batch-to-batch ink quality
  • Permanently trap contaminants without affecting critical ink properties
  • Remove oversized contaminants without stripping off colorants
  • Enjoy a longer service life while maintaining low filtration costs

Applications/Use

Microelectronics:

  • Graphic arts ink formulation filtration

Specifications

 

Operating Conditions

 

Operating temperature and maximum differential pressures in compatible fluids.1

 

Operating Temperature Maximum Differential Pressure
82 °C / 180 °F 1 bard / 15 psid
70 °C / 158 °F 2 bard / 30 psid
30 °C / 86 °F2 4.1 bard / 60 psid

 

1 Fluids that do not soften, swell or adversely affect the filter or materials of construction.

2 Recommended filter changeout: 2.3 bard / 40 psi.

 

Typical Liquid Flow Rate versus Differential Pressure3

 

3 For liquids with viscosities differing from water, multiply the pressure drop by the viscosity in cP.

 

 

Figure 1 Graded pore structure

Documents

Data Sheets

  • Profile® Star Filter Cartridges for Ink Jet Ink Formulation

    Select Language :