Profile® II Ink Jet Depth Filter Cartridges

For Pre and Final Filtration of Ink Jet Inks

Profile II Ink Jet depth filter cartridges are constructed from all-polypropylene components with ethylene-propylene O-rings. These absolute-rated depth filter cartridges have excellent compatibility with most ink systems where removal ratings from 0.3 to 10 µm are required. In addition, proven tapered-pore technology and a sanitary dual O-ring seal assure filter integrity and ease of use with a wide range of ink jet formulations.

Order Products

Removal Rating

0.2 µm

Emflon® II Membrane in Kleenpak™ Capsules serves the user's specific systematic needs. Pall offers options including gama-irradiatable, pre-sterilized and custom-made sets. All versions perform to the same top quality standard. Each unit is fully integrity testable and has the highly retentive Emflon II membrane. These capsule filters provide high air flows of both air and gas.

9 Products In Family

Fluorodyne® II DFL Membrane in Kleenpak™ Capsules provides many benefits to their users such as high protein transmission and rapid preservative recovery. DFL is ideal for sterilizing filtration of biopharmaceutical grade fluids. Solutions with active ingredients are carefully filtered throughout DFL's compact design. Each product includes a Certificate of Test for bacterial retention and fabrication integrity.

Validated sterilizing grade membranes for the most cost effective filtration of a wide range of liquids such as buffers, tissue culture media, and others

Emflon® PFR Membrane in Novasip™ Capsules have lower installation costs than comparable systems. Its steam sterilizing durability provides a long service life and low maintenance costs. Novasip™ filters use polyethermide because of its strong withstanding features against elevated temperature and pressure. Designed with air and vent applications Novasip™ filters can be used in a range of operating conditions.

Kleenpak™ Capsules with Posidyne® Membrane meet cleanliness requirement per USP Particulates in Injectable. It features positive Zeta potential for enhanced efficiency in aqueous solutions. Capsules contain a double-layer sterilizing membrane for high reliability and high-quality product. Filters are self-contained and designed for small sterile filtration systems throughout a range of acidic to basic solutions.

Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 1700 cm² EFA, ½ in. hose barb connections, pre-sterilized by gamma irradiation product photo

Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 1700 cm² EFA, ½ in. hose barb connections, pre-sterilized by gamma irradiation

Product ID: KA3V002PV6S
Unit of Measure
1/EA
Min Order Qty
1
Membrane Material
Polyvinylidene fluoride (PVDF)
Effective Filtration Area (Metric)
1700 cm²
See All Attributes

This product is currently not available. Please contact us for more information.

Fluorodyne® II DFL membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 1500 cm² EFA, 1-1½ in. sanitary flange connections, suitable for gamma irradiation product photo

Fluorodyne® II DFL membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 1500 cm² EFA, 1-1½ in. sanitary flange connections, suitable for gamma irradiation

Product ID: KA3DFLP1G
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
0.2 µm
Membrane Material
Polyvinylidene fluoride (PVDF)
Sterilization Option(s)
Suitable for Gamma Irradiation, Suitable for Autoclave
See All Attributes
Supor® EKV membrane in Kleenpak™ capsule, 0.2 µm removal rating, 375 cm² EFA, 1-1½ in. sanitary flange connections, suitable for gamma irradiation product photo

Supor® EKV membrane in Kleenpak™ capsule, 0.2 µm removal rating, 375 cm² EFA, 1-1½ in. sanitary flange connections, suitable for gamma irradiation

Product ID: KA1EKVP1G
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
0.2 µm
Membrane Material
Polyethersulfone (PES)
Effective Filtration Area
375 cm²
Sterilization Option(s)
Suitable for Gamma Irradiation, Suitable for Autoclave
Inlet Connection
1-1½ in (25-38 mm) sanitary flange
See All Attributes

This product is currently not available. Please contact us for more information.

Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 1700 cm² EFA, 1-1½ in. sanitary flange connections, pre-sterilized by gamma irradiation product photo

Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 1700 cm² EFA, 1-1½ in. sanitary flange connections, pre-sterilized by gamma irradiation

Product ID: KA3V002PV1S
Unit of Measure
1/EA
Min Order Qty
1
Membrane Material
Polyvinylidene fluoride (PVDF)
Effective Filtration Area (Metric)
1700 cm²
See All Attributes
Supor® EKV membrane in Kleenpak™ capsule, 0.2 µm removal rating, 1500 cm² EFA, ½ in. hose barb connections, suitable for gamma irradiation product photo

Supor® EKV membrane in Kleenpak™ capsule, 0.2 µm removal rating, 1500 cm² EFA, ½ in. hose barb connections, suitable for gamma irradiation

Product ID: KA3EKVP6G
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
0.2 µm
Membrane Material
Polyethersulfone (PES)
Effective Filtration Area
1500 cm²
Sterilization Option(s)
Suitable for Gamma Irradiation, Suitable for Autoclave
Inlet Connection
½ in (13 mm) hose barb
See All Attributes
Supor® EKV membrane in Kleenpak™ capsule, 0.2 µm removal rating, 1500 cm² EFA, ½ in. hose barb connections, pre-sterilized by gamma irradiation product photo

Supor® EKV membrane in Kleenpak™ capsule, 0.2 µm removal rating, 1500 cm² EFA, ½ in. hose barb connections, pre-sterilized by gamma irradiation

Product ID: KA3EKVP6S
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
0.2 µm
Membrane Material
Polyethersulfone (PES)
Effective Filtration Area
1500 cm²
Sterilization Option(s)
Provided Pre-Sterilized by Gamma Irradiation
Inlet Connection
½ in (13 mm) hose barb
See All Attributes
Fluorodyne® II DFL membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 800 cm² EFA, 1½ in. sanitary flange inlet and ½ in. hose barb outlet connections, pre-sterilized by gamma irradiation product photo

Fluorodyne® II DFL membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 800 cm² EFA, 1½ in. sanitary flange inlet and ½ in. hose barb outlet connections, pre-sterilized by gamma irradiation

Product ID: KA2DFLP16S
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
0.2 µm
Membrane Material
Polyvinylidene fluoride (PVDF)
Sterilization Option(s)
Provided Pre-Sterilized by Gamma Irradiation
See All Attributes

This product is currently not available. Please contact us for more information.

Description

Why choose Profile II ink jet depth filter cartridges?

A graded pore density means these ink filters provide longer service life and reduce the filtration cost per gallon/liter.

 

Additional benefits include:

 

  • Provide consistent from batch-to-batch ink quality
  • Permanently trap contaminants without affecting critical ink properties
  • Remove oversized contaminants without stripping off colorants
  • Enjoy a longer service life while maintaining low filtration costs

Applications/Use

Microelectronics:

  • Graphic arts ink formulation filtration

Specifications

 

Operating Conditions

 

Operating temperature and maximum differential pressures in compatible fluids.1

 

Operating Temperature Maximum Differential Pressure
82 °C / 180 °F 1 bard / 15 psid
70 °C / 158 °F 2 bard / 30 psid
30 °C / 86 °F2 4.1 bard / 60 psid

 

1 Fluids that do not soften, swell or adversely affect the filter or materials of construction.

2 Recommended filter changeout: 2.3 bard / 40 psi.

 

Typical Liquid Flow Rate versus Differential Pressure3

 

3 For liquids with viscosities differing from water, multiply the pressure drop by the viscosity in cP.

 

 

Figure 1 Graded pore structure

Documents

Data Sheets

  • Profile® Star Filter Cartridges for Ink Jet Ink Formulation

    Select Language :