Profile® II RFN Nylon Depth Filter – Gas, Liquid Filter Cartridges

For Liquid and Gas Applications 

Profile II RFN Series depth filter cartridges are for liquid and gas applications such as chemical, petrochemical, paint, resin coating, and food and beverage. They are comprised of an all-nylon filter medium with glass-filled polypropylene cores and available with glass-filled nylon cores for use with xylene, toluene, or other aromatics and high temperatures.  There is no binder resin as the fibers are “bonded” by intertwining during the manufacturing process.  As a result, these depth filter cartridges show no media migration.

Order Products

Product Type

Filter Cartridges

DFT Classic®, Filter Cartridges, Removal Rating 5 μm, Length 19.5 Inches, 304 stainless steel, Bulk packaging

Product ID: C005AW195A
Unit of Measure
10/EA
Min Order Qty
10
Removal Rating
5 µm
Cartridge Length (Imperial)
19.5 in
Cartridge Length (Metric)
495 mm
Cartridge Length (Metric)
49.5 cm
Cartridge Outer Diameter (OD) (Imperial)
2.5 in
Cartridge Outer Diameter (OD) (Metric)
6.4 cm
See All Attributes
FNC10R40SE product photo

FNC10R40SE

Product ID: FNC10R40SE
Unit of Measure
10/EA
Min Order Qty
10
Packaging
Bulk
See All Attributes
T010A10Y product photo

T010A10Y

Product ID: T010A10Y
Unit of Measure
1/EA
Min Order Qty
1
Packaging
Bulk
See All Attributes

AB4UY0207H

Product ID: AB4UY0207H
Unit of Measure
1/EA
Min Order Qty
1

Ultipor® N66 Filter Cartridges, Nylon Hardware, 0.45 µm Single Layer, 10 in, Single Open Ended Code 7, Silicone Elastomer O-ring

Product ID: ABN1NB7WH4
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
0.45 µm
Cartridge Length (Imperial)
10 in
Cartridge Length (Metric)
254 mm
Cartridge Length (Metric)
25.4 cm
Gasket / O-Ring Material
Silicone Elastomer
Gasket O-Ring Code
H4
See All Attributes
DFT Classic®, Filter Cartridges, Removal Rating 150 μm, Length 20 Inches, Polypropylene product photo

DFT Classic®, Filter Cartridges, Removal Rating 150 μm, Length 20 Inches, Polypropylene

Product ID: U150AW20U
Unit of Measure
10/EA
Min Order Qty
10
Packaging
Bulk
See All Attributes

Duo-Fine® , Filter Cartridges, Removal Rating 0.45 μm, Length 10 Inches, No Oring required M2 style only, SOE flat closed end fits housings with 020 O-ring post

Product ID: DFNT04510UXM2
Unit of Measure
30/EA
Min Order Qty
30
Removal Rating
0.45 µm
End Configuration
SOE flat closed end, fits housings with 020
Change Out Differential Pressure
2.4 bard

Profile® Nylon, Filter Cartridges, Removal Rating 40 μm, Nylon, Length 20 Inches

Product ID: RGN2FN400NPL
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
40 µm
Membrane Material
Nylon
Cartridge Length (Imperial)
20 in
Cartridge Length (Metric)
508 mm
Cartridge Length (Metric)
50.8 cm
Cartridge Outer Diameter (OD) (Imperial)
2.5 in
See All Attributes

S/W FILTER CRTDG, FDA POLYPROPYLENE, 10U

Product ID: FF FFP10R30P
Unit of Measure
15/EA
Min Order Qty
15

Junior Filter HDC II 4.5µm

Product ID: MCY4463J045J
Unit of Measure
12/EA
Min Order Qty
12
Poly-Fine® II, Filter Cartridges, Removal Rating 10 μm, Polypropylene, Length 40 Inches, EPDM, SOE fin end external 225 O-ring product photo

Poly-Fine® II, Filter Cartridges, Removal Rating 10 μm, Polypropylene, Length 40 Inches, EPDM, SOE fin end external 225 O-ring

Product ID: PFT1040UEM22
Unit of Measure
1/EA
Min Order Qty
1
Micron
10 µm
Filtro 10" Ultipor GF+ 20µm product photo

Filtro 10" Ultipor GF+ 20µm

Product ID: MCY1001U200ZH13
Unit of Measure
1/EA
Min Order Qty
1

This product is currently not available. Please contact us for more information.

Description

Why Choose Profile II RFN Series depth filter cartridges?

 

The Profile II RFN elements have an absolute rated downstream section leading to 99.98% efficiency in liquid and a continuously profiled pore size upstream section for increased service life. 

Product Highlights

  • All nylon filter medium with glass-filled polypropylene cores
  • Increased service life

Applications/Uses

The Profile II RFN filter has numerous applications in a broad range of industries such as chemical, petrochemical, pharmaceutical, paint, resin coating, food, beverage and cosmetics.

 

 

Chemicals and Polymer:

  • Chemicals - Final product (liquid), raw material (gas, air, liquid) and intermediate product (other)
  • Petrochemicals (Amine, Benfield, other solvent loops)
  • Polymer - Carbon fiber, nylon and polyurethane production

Oil and Gas:

  • Upstream Injection Water & SRU
  • Midstream LNG acid gas
  • Midstream glycol filtration
  • Midstream Process Water
  • Refinery amine scrubbing systems

Specifications

 

The recommended maximum pressure differential for the standard RFN Series filters is 75 psi up to 86 °F (30 °C), 50 psi up to 158 °F (70 °C), and 35 psi up to 180 °F (82 °C). For the GN Series filters with glass filled nylon cores, recommended maximum pressure differential is 90 psi up to 86 °F (30 °C), 80 psi up to 158 °F (70 °C), 70 psi up to 212 °F (100 °C), and 50 psi up to 300 °F (150 °C).

 

If the fluid filtered is compatible with polypropylene and temperature below 194 °F (90 °C), Profile II RF Polypropylene Series elements, described in Data Sheet E1 and Bulletin PRO 400, may be suitable. Pall Corporation’s Scientific and Laboratory Services group will supply compatibility information for both nylon and polypropylene upon request.

 

Cartridge Grade Grade Removal Rating Clean Pressure Drop Typical Aqueous Flow (GPM/10" Cartridge)
  Liquid Service Liquid Service Gaseous Service  
  Rating in μm at % Efficiency Aqueous Pressure Drop (psi/gpm)2 CFM of Air per PSI per 10" Cartridge3  
  90% 99% 99.9% 99.98%      
050 2.0 3.0 4 5 0.8 11 3 - 8
100 6.5 7.5 9 10 0.3 29 6 - 15
200 10 14 18 20 0.10 75 10 - 15
400  20 30 35 40 0.05 207 10 - 15
700 32 50 701 - <0.05 415 10 - 15

 

1 Extrapolated values.

2 Pressure drop in PSI per GPM for a single 10″ module. For multiple elements, divide by number of modules. For fluids other than water, multiply by viscosity in centipoise.

3 For longer modules, increase the flow rates listed in proportion. The flow rates listed do not take into account pressure losses due to flow in the internal diameter of the element, which becomes significant above about 40 to 60 cfm.

Documents

Data Sheets

  • Profile® II RFN Series Filter Elements

    Select Language :