Profile® II RFN Nylon Depth Filter – Gas, Liquid Filter Cartridges

For Liquid and Gas Applications 

Profile II RFN Series depth filter cartridges are for liquid and gas applications such as chemical, petrochemical, paint, resin coating, and food and beverage. They are comprised of an all-nylon filter medium with glass-filled polypropylene cores and available with glass-filled nylon cores for use with xylene, toluene, or other aromatics and high temperatures.  There is no binder resin as the fibers are “bonded” by intertwining during the manufacturing process.  As a result, these depth filter cartridges show no media migration.

Order Products

Red1000 Glass Fiber 12 micron (Beta 1000) Nitrile 36in 91.44cm

Product ID: HC2296FKS36H
Unit of Measure
1/EA
Min Order Qty
6
Anti-Static
No
Beta Rating
BETA 1000
Element Series
HC2296
Family
Red1000
Filter Media
Glass Fiber
Filter Removal Rating (μm)
12 µm
See All Attributes

Ultipor III Glass Fiber 5 micron (Beta 1000) Nitrile 8in 20.32cm length

Product ID: HC9601FDP8H#28
Unit of Measure
1/EA
Min Order Qty
1
Anti-Static
No
Beta Rating
BETA 1000
Element Series
HC9601
Family
Ultipor III
Filter Media
Glass Fiber
Filter Removal Rating (μm)
5 µm
See All Attributes
RT250A10S product photo

RT250A10S

Product ID: RT250A10S
Unit of Measure
30/EA
Min Order Qty
30
Packaging
Bulk
See All Attributes
HT0644GK200G product photo

HT0644GK200G

Product ID: HT0644GK200G
Unit of Measure
10/EA
Min Order Qty
10

HVP902/903 KIT VAC PUMP SRV

Product ID: HVP902903KITS00001
Unit of Measure
1/EA
Min Order Qty
1

Ultipor, 6000psi Non-bypass Simplex Hsg, 1in BSP Ports, 8in Length, Fluorocarbon Seals

Product ID: HZ9801C16SW1
Unit of Measure
1/EA
Min Order Qty
1
Inlet/Outlet Connections Type
BSP
Cartridge Length (Imperial)
8 in
Family
Ultipor
Pressure Rating
6000 psi
Port Size
1 in
Number of Cartridges
1
See All Attributes

Ultipor, 6000psi Non-bypass Simplex Hsg, 2in Flange Ports, 39in Length, Fluorocarbon Seals

Product ID: HZ9901G32XW1
Unit of Measure
1/EA
Min Order Qty
1
Inlet/Outlet Connections Type
Metric Flange (6000 #)
Cartridge Length (Imperial)
39 in
Family
Ultipor
Pressure Rating
6000 psi
Port Size
2 in
Number of Cartridges
1
See All Attributes
IDL11GN12H product photo

IDL11GN12H

Product ID: IDL11GN12H
Unit of Measure
1/EA
Min Order Qty
1
FEATURED

Emflon® PFRW Kleenpak™ Capsules, KA3PFRW1

Product ID: KA3PFRW1
Unit of Measure
1/EA
Min Order Qty
1
Membrane Material
Double Layer PTFE
Maximum Differential Pressure
3.5 bard @ < 40° C (68◦ F)
Cage, Core, Fin End and Endcap
Polypropylene
Food Contact Compliant
Yes

LCMEH

Product ID: LCMEH
Unit of Measure
1/EA
Min Order Qty
1

AquaSep EL L/L Coalescer, 6in length, 2.75in diameter, ≤15ppm separation level, 24μm Beta 50 solids removal rating

Product ID: LCS06ELBH
Unit of Measure
4/EA
Min Order Qty
4
Maximum Operating Temperature (F)
140 °F
Maximum Operating Temperature (C)
60 °C
Change out pressure drop (bar)
1.03 bar
Change out pressure drop (psid)
15 psid
Maximum differential pressure rating (bar)
3.5 bar
Maximum differential pressure rating (psid)
50 psid
See All Attributes

PhaseSep L/L Coalescer, 6in length, 2.75in diameter, ≤15ppm separation level

Product ID: LCS06H1HH
Unit of Measure
1/EA
Min Order Qty
1
Maximum Operating Temperature (F)
300 °F
Maximum Operating Temperature (C)
149 °C
Change out pressure drop (bar)
1.03 bar
Change out pressure drop (psid)
15 psid
Maximum differential pressure rating (bar)
3.5 bar
Maximum differential pressure rating (psid)
50 psid
See All Attributes

Description

Why Choose Profile II RFN Series depth filter cartridges?

 

The Profile II RFN elements have an absolute rated downstream section leading to 99.98% efficiency in liquid and a continuously profiled pore size upstream section for increased service life. 

Product Highlights

  • All nylon filter medium with glass-filled polypropylene cores
  • Increased service life

Applications/Uses

The Profile II RFN filter has numerous applications in a broad range of industries such as chemical, petrochemical, pharmaceutical, paint, resin coating, food, beverage and cosmetics.

 

 

Chemicals and Polymer:

  • Chemicals - Final product (liquid), raw material (gas, air, liquid) and intermediate product (other)
  • Petrochemicals (Amine, Benfield, other solvent loops)
  • Polymer - Carbon fiber, nylon and polyurethane production

Oil and Gas:

  • Upstream Injection Water & SRU
  • Midstream LNG acid gas
  • Midstream glycol filtration
  • Midstream Process Water
  • Refinery amine scrubbing systems

Specifications

 

The recommended maximum pressure differential for the standard RFN Series filters is 75 psi up to 86 °F (30 °C), 50 psi up to 158 °F (70 °C), and 35 psi up to 180 °F (82 °C). For the GN Series filters with glass filled nylon cores, recommended maximum pressure differential is 90 psi up to 86 °F (30 °C), 80 psi up to 158 °F (70 °C), 70 psi up to 212 °F (100 °C), and 50 psi up to 300 °F (150 °C).

 

If the fluid filtered is compatible with polypropylene and temperature below 194 °F (90 °C), Profile II RF Polypropylene Series elements, described in Data Sheet E1 and Bulletin PRO 400, may be suitable. Pall Corporation’s Scientific and Laboratory Services group will supply compatibility information for both nylon and polypropylene upon request.

 

Cartridge Grade Grade Removal Rating Clean Pressure Drop Typical Aqueous Flow (GPM/10" Cartridge)
  Liquid Service Liquid Service Gaseous Service  
  Rating in μm at % Efficiency Aqueous Pressure Drop (psi/gpm)2 CFM of Air per PSI per 10" Cartridge3  
  90% 99% 99.9% 99.98%      
050 2.0 3.0 4 5 0.8 11 3 - 8
100 6.5 7.5 9 10 0.3 29 6 - 15
200 10 14 18 20 0.10 75 10 - 15
400  20 30 35 40 0.05 207 10 - 15
700 32 50 701 - <0.05 415 10 - 15

 

1 Extrapolated values.

2 Pressure drop in PSI per GPM for a single 10″ module. For multiple elements, divide by number of modules. For fluids other than water, multiply by viscosity in centipoise.

3 For longer modules, increase the flow rates listed in proportion. The flow rates listed do not take into account pressure losses due to flow in the internal diameter of the element, which becomes significant above about 40 to 60 cfm.

Documents

Data Sheets

  • Profile® II RFN Series Filter Elements

    Select Language :