Profile® II RFN Nylon Depth Filter – Gas, Liquid Filter Cartridges

For Liquid and Gas Applications 

Profile II RFN Series depth filter cartridges are for liquid and gas applications such as chemical, petrochemical, paint, resin coating, and food and beverage. They are comprised of an all-nylon filter medium with glass-filled polypropylene cores and available with glass-filled nylon cores for use with xylene, toluene, or other aromatics and high temperatures.  There is no binder resin as the fibers are “bonded” by intertwining during the manufacturing process.  As a result, these depth filter cartridges show no media migration.

Order Products

Industries

Microelectronics

MPF2230F002EH1

Product ID: MPF2230F002EH1
Unit of Measure
1/EA
Min Order Qty
1
NXT 150-20U product photo

Nexis, NXT, 150 μm, 50.8 cm (20 in), DOE industrial (no end caps)

Product ID: NXT15020U
Unit of Measure
1/EA
Min Order Qty
1
Micron
150 micron

Profile® Star Filter Cartridges, Removal Rating 1 μm, Polypropylene, Length 20 inches, Ethylene Propylene, double O-ring with flat end

Product ID: AB2A0103J
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
1 µm
Membrane Material
Polypropylene
Filter Cartridge Style
Code 3
Cartridge Length (Imperial)
20 in
Cartridge Length (Metric)
508 mm
Cartridge Length (Metric)
50.8 cm
See All Attributes

Nexis® T Filter Cartridges, Removal Rating 200 μm, Polypropylene, EPDM, DOE with elastomer gasket seals and end caps

Product ID: NXT200TFUDOEE47
Unit of Measure
5/EA
Min Order Qty
5
Removal Rating
200 µm
Membrane Material
Polypropylene
Gasket / O-Ring Material
EPDM
End Configuration Code
DOE
End Configuration
DOE - DOE with elastomer gasket seals and end caps
Cartridge Type
NXT
See All Attributes

Nexis® T Filter Cartridges, Removal Rating 20 μm, Polypropylene, Length 29.25 inches

Product ID: NXT202925U
Unit of Measure
20/EA
Min Order Qty
20
Removal Rating
20 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
29.25 in
Cartridge Length (Metric)
743 mm
Cartridge Length (Metric)
74.3 cm
Gasket / O-Ring Material
NA
See All Attributes
NXT 5-10U-DOET product photo
Unit of Measure
1/EA
Min Order Qty
1
Micron
5 micron
J,304L,18X48 product photo

J,304L,18X48

Product ID: P1174041
Unit of Measure
1/IN2
Min Order Qty
1
ORH1-346 product photo

ORH1-346

Product ID: P2060104
Unit of Measure
1/EA
Min Order Qty
1
USP-143 product photo

USP-143

Product ID: P2215486
Unit of Measure
1/EA
Min Order Qty
1
PolyFine-II Filter Cartridge, Highly asymmetric polysulfone, 0.2 µm, 10 in, EPDM, M3 product photo

PolyFine-II Filter Cartridge, Highly asymmetric polysulfone, 0.2 µm, 10 in, EPDM, M3

Product ID: PFT0210UEM3513
Unit of Measure
1/EA
Min Order Qty
1
Micron
0.2 µm
FSL315CAP  204 product photo

FSL315CAP 204

Product ID: FSL315CAP204
Unit of Measure
1/EA
Min Order Qty
1
C050A10U product photo

C050A10U

Product ID: C050A10U
Unit of Measure
1/EA
Min Order Qty
1
Packaging
Bulk
See All Attributes

Description

Why Choose Profile II RFN Series depth filter cartridges?

 

The Profile II RFN elements have an absolute rated downstream section leading to 99.98% efficiency in liquid and a continuously profiled pore size upstream section for increased service life. 

Product Highlights

  • All nylon filter medium with glass-filled polypropylene cores
  • Increased service life

Applications/Uses

The Profile II RFN filter has numerous applications in a broad range of industries such as chemical, petrochemical, pharmaceutical, paint, resin coating, food, beverage and cosmetics.

 

 

Chemicals and Polymer:

  • Chemicals - Final product (liquid), raw material (gas, air, liquid) and intermediate product (other)
  • Petrochemicals (Amine, Benfield, other solvent loops)
  • Polymer - Carbon fiber, nylon and polyurethane production

Oil and Gas:

  • Upstream Injection Water & SRU
  • Midstream LNG acid gas
  • Midstream glycol filtration
  • Midstream Process Water
  • Refinery amine scrubbing systems

Specifications

 

The recommended maximum pressure differential for the standard RFN Series filters is 75 psi up to 86 °F (30 °C), 50 psi up to 158 °F (70 °C), and 35 psi up to 180 °F (82 °C). For the GN Series filters with glass filled nylon cores, recommended maximum pressure differential is 90 psi up to 86 °F (30 °C), 80 psi up to 158 °F (70 °C), 70 psi up to 212 °F (100 °C), and 50 psi up to 300 °F (150 °C).

 

If the fluid filtered is compatible with polypropylene and temperature below 194 °F (90 °C), Profile II RF Polypropylene Series elements, described in Data Sheet E1 and Bulletin PRO 400, may be suitable. Pall Corporation’s Scientific and Laboratory Services group will supply compatibility information for both nylon and polypropylene upon request.

 

Cartridge Grade Grade Removal Rating Clean Pressure Drop Typical Aqueous Flow (GPM/10" Cartridge)
  Liquid Service Liquid Service Gaseous Service  
  Rating in μm at % Efficiency Aqueous Pressure Drop (psi/gpm)2 CFM of Air per PSI per 10" Cartridge3  
  90% 99% 99.9% 99.98%      
050 2.0 3.0 4 5 0.8 11 3 - 8
100 6.5 7.5 9 10 0.3 29 6 - 15
200 10 14 18 20 0.10 75 10 - 15
400  20 30 35 40 0.05 207 10 - 15
700 32 50 701 - <0.05 415 10 - 15

 

1 Extrapolated values.

2 Pressure drop in PSI per GPM for a single 10″ module. For multiple elements, divide by number of modules. For fluids other than water, multiply by viscosity in centipoise.

3 For longer modules, increase the flow rates listed in proportion. The flow rates listed do not take into account pressure losses due to flow in the internal diameter of the element, which becomes significant above about 40 to 60 cfm.

Documents

Data Sheets

  • Profile® II RFN Series Filter Elements

    Select Language :