Profile® II RFN Nylon Depth Filter – Gas, Liquid Filter Cartridges

For Liquid and Gas Applications 

Profile II RFN Series depth filter cartridges are for liquid and gas applications such as chemical, petrochemical, paint, resin coating, and food and beverage. They are comprised of an all-nylon filter medium with glass-filled polypropylene cores and available with glass-filled nylon cores for use with xylene, toluene, or other aromatics and high temperatures.  There is no binder resin as the fibers are “bonded” by intertwining during the manufacturing process.  As a result, these depth filter cartridges show no media migration.

Order Products

Product Type

Large Format Filters

Nexis® High Flow Large Format Filters, Removal Rating 10 µm, Length 20 inches

Product ID: HFNX620Y100JU
Unit of Measure
4/EA
Min Order Qty
4
Cartridge Length
20/508 inch/mm
Filter Grade
10 µm
Outside Diameter (Imperial)
6 in
Outside Diameter (Metric)
152.4 mm
Cartridge Length (Imperial)
20 in
Cartridge Length (Metric)
508 mm
See All Attributes

Nexis® High Flow Large Format Filters, Removal Rating 75 µm, Length 20 inches

Product ID: HFNX620Y750H13
Unit of Measure
4/EA
Min Order Qty
4
Cartridge Length
20/508 inch/mm
Filter Grade
75 µm
Outside Diameter (Imperial)
6 in
Outside Diameter (Metric)
152.4 mm
Cartridge Length (Imperial)
20 in
Cartridge Length (Metric)
508 mm
See All Attributes

Nexis® High Flow Large Format Filters, Removal Rating 10 µm, Length 40 inches

Product ID: HFNX640Y100J
Unit of Measure
4/EA
Min Order Qty
4
Cartridge Length
40/1016 inch/mm
Filter Grade
10 µm
Outside Diameter (Imperial)
6 in
Outside Diameter (Metric)
152.4 mm
Cartridge Length (Imperial)
40 in
Cartridge Length (Metric)
1016 mm
See All Attributes

Nexis® High Flow Large Format Filters, Removal Rating 100 µm, Length 40 inches

Product ID: HFNX640Y1000J
Unit of Measure
4/EA
Min Order Qty
4
Cartridge Length
40/1016 inch/mm
Filter Grade
100 µm
Outside Diameter (Imperial)
6 in
Outside Diameter (Metric)
152.4 mm
Cartridge Length (Imperial)
40 in
Cartridge Length (Metric)
1016 mm
See All Attributes

Nexis® High Flow Large Format Filters, Removal Rating 15 µm, Length 40 inches, Nitrile O-ring

Product ID: HFNX640Y150H13
Unit of Measure
4/EA
Min Order Qty
4
Cartridge Length
40/1016 inch/mm
Filter Grade
15 µm
Outside Diameter (Imperial)
6 in
Outside Diameter (Metric)
152.4 mm
Cartridge Length (Imperial)
40 in
Cartridge Length (Metric)
1016 mm
See All Attributes

Nexis® High Flow Large Format Filters, Removal Rating 10 µm, Length 40 inches, Nitrile O-ring

Product ID: HFNX640Y100H13
Unit of Measure
4/EA
Min Order Qty
4
Cartridge Length
40/1016 inch/mm
Filter Grade
10 µm
Outside Diameter (Imperial)
6 in
Outside Diameter (Metric)
152.4 mm
Cartridge Length (Imperial)
40 in
Cartridge Length (Metric)
1016 mm
See All Attributes

Nexis® High Flow Large Format Filters, Removal Rating 40 µm, Length 20 inches

Product ID: HFNX620Y400H13
Unit of Measure
12/EA
Min Order Qty
12
Cartridge Length
20/508 inch/mm
Filter Grade
40 µm
Outside Diameter (Imperial)
6 in
Outside Diameter (Metric)
152.4 mm
Cartridge Length (Imperial)
20 in
Cartridge Length (Metric)
508 mm
See All Attributes

Nexis® High Flow Large Format Filters, Removal Rating 15 µm, Length 40 inches

Product ID: HFNX640Y150J
Unit of Measure
4/EA
Min Order Qty
4
Cartridge Length
40/1016 inch/mm
Filter Grade
15 µm
Outside Diameter (Imperial)
6 in
Outside Diameter (Metric)
152.4 mm
Cartridge Length (Imperial)
40 in
Cartridge Length (Metric)
1016 mm
See All Attributes

Nexis® High Flow Large Format Filters, Length 40 inches

Product ID: HFNX640Y050JRO198
Unit of Measure
4/EA
Min Order Qty
4
Cartridge Length
40/1016 inch/mm
Outside Diameter (Imperial)
6 in
Outside Diameter (Metric)
152.4 mm
Cartridge Length (Imperial)
40 in
Cartridge Length (Metric)
1016 mm

Nexis® High Flow Large Format Filters, Removal Rating 40 µm, Length 40 inches, Nitrile O-ring

Product ID: HFNX640Y400H13
Unit of Measure
4/EA
Min Order Qty
4
Cartridge Length
40/1016 inch/mm
Filter Grade
40 µm
Outside Diameter (Imperial)
6 in
Outside Diameter (Metric)
152.4 mm
Cartridge Length (Imperial)
40 in
Cartridge Length (Metric)
1016 mm
See All Attributes

Nexis® High Flow Large Format Filters, Removal Rating 15 µm, Length 60 inches, Fluorocarbon O-ring

Product ID: HFNX660Y150H
Unit of Measure
4/EA
Min Order Qty
4
Cartridge Length
60/1524 inch/mm
Filter Grade
15 µm
Outside Diameter (Imperial)
6 in
Outside Diameter (Metric)
152.4 mm
Cartridge Length (Imperial)
60 in
Cartridge Length (Metric)
1524 mm
See All Attributes

Marksman™, Large Format Filters, Removal Rating 10 μm, Polypropylene, Length Size 1 bag, No flange

Product ID: NXAM101UNF
Unit of Measure
1/EA
Min Order Qty
1
Cartridge Length
Size 1 bag
Filter Grade
10 µm
Hardware Material
Polypropylene
Media Material
Polypropylene
Outside Diameter (Imperial)
6 in
Outside Diameter (Metric)
152 mm
See All Attributes

Description

Why Choose Profile II RFN Series depth filter cartridges?

 

The Profile II RFN elements have an absolute rated downstream section leading to 99.98% efficiency in liquid and a continuously profiled pore size upstream section for increased service life. 

Product Highlights

  • All nylon filter medium with glass-filled polypropylene cores
  • Increased service life

Applications/Uses

The Profile II RFN filter has numerous applications in a broad range of industries such as chemical, petrochemical, pharmaceutical, paint, resin coating, food, beverage and cosmetics.

 

 

Chemicals and Polymer:

  • Chemicals - Final product (liquid), raw material (gas, air, liquid) and intermediate product (other)
  • Petrochemicals (Amine, Benfield, other solvent loops)
  • Polymer - Carbon fiber, nylon and polyurethane production

Oil and Gas:

  • Upstream Injection Water & SRU
  • Midstream LNG acid gas
  • Midstream glycol filtration
  • Midstream Process Water
  • Refinery amine scrubbing systems

Specifications

 

The recommended maximum pressure differential for the standard RFN Series filters is 75 psi up to 86 °F (30 °C), 50 psi up to 158 °F (70 °C), and 35 psi up to 180 °F (82 °C). For the GN Series filters with glass filled nylon cores, recommended maximum pressure differential is 90 psi up to 86 °F (30 °C), 80 psi up to 158 °F (70 °C), 70 psi up to 212 °F (100 °C), and 50 psi up to 300 °F (150 °C).

 

If the fluid filtered is compatible with polypropylene and temperature below 194 °F (90 °C), Profile II RF Polypropylene Series elements, described in Data Sheet E1 and Bulletin PRO 400, may be suitable. Pall Corporation’s Scientific and Laboratory Services group will supply compatibility information for both nylon and polypropylene upon request.

 

Cartridge Grade Grade Removal Rating Clean Pressure Drop Typical Aqueous Flow (GPM/10" Cartridge)
  Liquid Service Liquid Service Gaseous Service  
  Rating in μm at % Efficiency Aqueous Pressure Drop (psi/gpm)2 CFM of Air per PSI per 10" Cartridge3  
  90% 99% 99.9% 99.98%      
050 2.0 3.0 4 5 0.8 11 3 - 8
100 6.5 7.5 9 10 0.3 29 6 - 15
200 10 14 18 20 0.10 75 10 - 15
400  20 30 35 40 0.05 207 10 - 15
700 32 50 701 - <0.05 415 10 - 15

 

1 Extrapolated values.

2 Pressure drop in PSI per GPM for a single 10″ module. For multiple elements, divide by number of modules. For fluids other than water, multiply by viscosity in centipoise.

3 For longer modules, increase the flow rates listed in proportion. The flow rates listed do not take into account pressure losses due to flow in the internal diameter of the element, which becomes significant above about 40 to 60 cfm.

Documents

Data Sheets

  • Profile® II RFN Series Filter Elements

    Select Language :