Profile® II RFN Nylon Depth Filter – Gas, Liquid Filter Cartridges

For Liquid and Gas Applications 

Profile II RFN Series depth filter cartridges are for liquid and gas applications such as chemical, petrochemical, paint, resin coating, and food and beverage. They are comprised of an all-nylon filter medium with glass-filled polypropylene cores and available with glass-filled nylon cores for use with xylene, toluene, or other aromatics and high temperatures.  There is no binder resin as the fibers are “bonded” by intertwining during the manufacturing process.  As a result, these depth filter cartridges show no media migration.

Order Products

Product Type

Sheet Depth Filter Modules

SUPRApak PW 7700 MW

Product ID: 5303104/M
Unit of Measure
1/EA
Min Order Qty
1
Core Drainage Discs
Polypropylene
Diameter (Imperial)
11.2 in
Diameter (Metric)
285 mm
Filter Media
Cellulose
Filtration Area (Imperial)
29.1 ft²
Filtration Area (Metric)
2.7 m²
See All Attributes
SUPRAdisc SD II 50 200X050C440SP product photo

SUPRAdisc SD II 50 200X050C440SP

Product ID: 7007253
Unit of Measure
1/EA
Min Order Qty
1
SUPRAdisc SD II 150 200X150C440SP product photo

SUPRAdisc SD II 150 200X150C440SP

Product ID: 7007321
Unit of Measure
1/EA
Min Order Qty
1

SUPRAdisc SD II 100 200X100C232SPW

Product ID: 7007872
Unit of Measure
1/EA
Min Order Qty
1
1. Recommended Max. Backpressure During Backwash
0.5 bar
2. Recommended Max. Backpressure During Backwash
7.25 psid
Adaptor Type
Double Open End, Flat Gasket
Core Drainage Discs
Polypropylene
Diameter (Imperial)
12 in
Diameter (Metric)
287 mm
See All Attributes

Supracap 50 depth filter capsules are designed for developing and optimizing a process during scale-up and scale-down studies. They can be used to quickly and accurately determine which series and grade of depth filter media will provide the best performance as well as the necessary filtration area required to meet process volume

27 Products In Family

SUPRApak PW 5900 SW

Product ID: 5302742/S
Unit of Measure
1/EA
Min Order Qty
1
Diameter (Imperial)
7.5 in
Diameter (Metric)
183 mm
Filter Media
Kieselguhr, Perlite and Cellulose Fibers
Filtration Area (Imperial)
4.3 ft²
Filtration Area (Metric)
0.4 m²
Food Contact Compliant
Yes
See All Attributes

SUPRApak PW 5200 SW

Product ID: 5302800/S
Unit of Measure
1/EA
Min Order Qty
1
Diameter (Imperial)
7.5 in
Diameter (Metric)
183 mm
Filter Media
Kieselguhr, Perlite and Cellulose Fibers
Filtration Area (Imperial)
4.3 ft²
Filtration Area (Metric)
0.4 m²
Food Contact Compliant
Yes
See All Attributes

SUPRApak PW 7100 SW

Product ID: 5303072/S
Unit of Measure
1/EA
Min Order Qty
1
Diameter (Imperial)
7.5 in
Diameter (Metric)
183 mm
Filter Media
Kieselguhr, Perlite and Cellulose Fibers
Filtration Area (Imperial)
4.3 ft²
Filtration Area (Metric)
0.4 m²
Food Contact Compliant
Yes
See All Attributes

SUPRApak SW 7700 LW

Product ID: 5303103
Unit of Measure
1/EA
Min Order Qty
1
Core Drainage Discs
Polypropylene
Diameter (Imperial)
16 in
Diameter (Metric)
410 mm
Filter Media
Cellulose
Filtration Area (Imperial)
86.1 ft²
Filtration Area (Metric)
8 m²
See All Attributes

SUPRApak SH 5900 LW

Product ID: 5303133
Unit of Measure
1/EA
Min Order Qty
1
Core Drainage Discs
Polypropylene
Diameter (Imperial)
16 in
Diameter (Metric)
410 mm
Filter Media
Kieselguhr, Perlite and Cellulose Fibers
Filtration Area (Imperial)
86.1 ft²
Filtration Area (Metric)
8 m²
See All Attributes

SUPRApak SH 5700 LW

Product ID: 5303131
Unit of Measure
1/EA
Min Order Qty
1
Core Drainage Discs
Polypropylene
Diameter (Imperial)
16 in
Diameter (Metric)
410 mm
Filter Media
Kieselguhr, Perlite and Cellulose Fibers
Filtration Area (Imperial)
86.1 ft²
Filtration Area (Metric)
8 m²
See All Attributes
SUPRAdisc SD II EK 1 200XEK1S232SP product photo

SUPRAdisc SD II EK 1 200XEK1S232SP

Product ID: 7005243
Unit of Measure
1/STK
Min Order Qty
1

Description

Why Choose Profile II RFN Series depth filter cartridges?

 

The Profile II RFN elements have an absolute rated downstream section leading to 99.98% efficiency in liquid and a continuously profiled pore size upstream section for increased service life. 

Product Highlights

  • All nylon filter medium with glass-filled polypropylene cores
  • Increased service life

Applications/Uses

The Profile II RFN filter has numerous applications in a broad range of industries such as chemical, petrochemical, pharmaceutical, paint, resin coating, food, beverage and cosmetics.

 

 

Chemicals and Polymer:

  • Chemicals - Final product (liquid), raw material (gas, air, liquid) and intermediate product (other)
  • Petrochemicals (Amine, Benfield, other solvent loops)
  • Polymer - Carbon fiber, nylon and polyurethane production

Oil and Gas:

  • Upstream Injection Water & SRU
  • Midstream LNG acid gas
  • Midstream glycol filtration
  • Midstream Process Water
  • Refinery amine scrubbing systems

Specifications

 

The recommended maximum pressure differential for the standard RFN Series filters is 75 psi up to 86 °F (30 °C), 50 psi up to 158 °F (70 °C), and 35 psi up to 180 °F (82 °C). For the GN Series filters with glass filled nylon cores, recommended maximum pressure differential is 90 psi up to 86 °F (30 °C), 80 psi up to 158 °F (70 °C), 70 psi up to 212 °F (100 °C), and 50 psi up to 300 °F (150 °C).

 

If the fluid filtered is compatible with polypropylene and temperature below 194 °F (90 °C), Profile II RF Polypropylene Series elements, described in Data Sheet E1 and Bulletin PRO 400, may be suitable. Pall Corporation’s Scientific and Laboratory Services group will supply compatibility information for both nylon and polypropylene upon request.

 

Cartridge Grade Grade Removal Rating Clean Pressure Drop Typical Aqueous Flow (GPM/10" Cartridge)
  Liquid Service Liquid Service Gaseous Service  
  Rating in μm at % Efficiency Aqueous Pressure Drop (psi/gpm)2 CFM of Air per PSI per 10" Cartridge3  
  90% 99% 99.9% 99.98%      
050 2.0 3.0 4 5 0.8 11 3 - 8
100 6.5 7.5 9 10 0.3 29 6 - 15
200 10 14 18 20 0.10 75 10 - 15
400  20 30 35 40 0.05 207 10 - 15
700 32 50 701 - <0.05 415 10 - 15

 

1 Extrapolated values.

2 Pressure drop in PSI per GPM for a single 10″ module. For multiple elements, divide by number of modules. For fluids other than water, multiply by viscosity in centipoise.

3 For longer modules, increase the flow rates listed in proportion. The flow rates listed do not take into account pressure losses due to flow in the internal diameter of the element, which becomes significant above about 40 to 60 cfm.

Documents

Data Sheets

  • Profile® II RFN Series Filter Elements

    Select Language :