Profile® II RFN Nylon Depth Filter – Gas, Liquid Filter Cartridges

For Liquid and Gas Applications 

Profile II RFN Series depth filter cartridges are for liquid and gas applications such as chemical, petrochemical, paint, resin coating, and food and beverage. They are comprised of an all-nylon filter medium with glass-filled polypropylene cores and available with glass-filled nylon cores for use with xylene, toluene, or other aromatics and high temperatures.  There is no binder resin as the fibers are “bonded” by intertwining during the manufacturing process.  As a result, these depth filter cartridges show no media migration.

Order Products

Filter Media

Wire Mesh

HC2226EOJ6H50

Product ID: HC2226EOJ6H50
Unit of Measure
1/EA
Min Order Qty
1
Anti-Static
No
Element Series
HC2226
Family
Red1000
Filter Media
Wire Mesh
Filter Removal Rating (μm)
22 µm
Nominal Length (Imperial)
6 in
See All Attributes

HC2233EOJ6H

Product ID: HC2233EOJ6H
Unit of Measure
1/EA
Min Order Qty
1
Anti-Static
No
Element Series
HC2233
Family
Red1000
Filter Media
Wire Mesh
Filter Removal Rating (μm)
22 µm
Nominal Length (Imperial)
6 in
See All Attributes

Red1000 Wire Mesh 50 micron Nitrile 15in 38.1cm

Product ID: HC2286EOM15H50
Unit of Measure
1/EA
Min Order Qty
1
Anti-Static
No
Element Series
HC2286
Family
Red1000
Filter Media
Wire Mesh
Filter Removal Rating
50 micron
Filter Removal Rating (μm)
50 µm
See All Attributes

Red1000 Wire Mesh 50 micron Nitrile 30in 76.2cm

Product ID: HC2286EOM30H50
Unit of Measure
1/EA
Min Order Qty
1
Anti-Static
No
Element Series
HC2286
Family
Red1000
Filter Media
Wire Mesh
Filter Removal Rating
50 micron
Filter Removal Rating (μm)
50 µm
See All Attributes

HC2296EOM36H50

Product ID: HC2296EOM36H50
Unit of Measure
1/EA
Min Order Qty
1
Anti-Static
No
Element Series
HC2296
Family
Red1000
Filter Media
Wire Mesh
Filter Removal Rating
50 micron
Filter Removal Rating (μm)
50 µm
See All Attributes

Ultipor III Wire Mesh 50 micron Nitrile 26in 66.04cm

Product ID: HC8300EOM26H
Unit of Measure
1/EA
Min Order Qty
1
Anti-Static
No
Element Series
HC8300
Family
Ultipor III
Filter Media
Wire Mesh
Filter Removal Rating (μm)
50 µm
Nominal Length (Imperial)
26 in
See All Attributes

HC8300EOT16H

Product ID: HC8300EOT16H
Unit of Measure
6/EA
Min Order Qty
6
Anti-Static
No
Element Series
HC8300
Family
Ultipor III
Filter Media
Wire Mesh
Filter Removal Rating (μm)
225 µm
Nominal Length (Imperial)
16 in
See All Attributes

Ultipor III Wire Mesh 50 micron Nitrile 13in 33.02cm

Product ID: HC9600EOM13H
Unit of Measure
1/EA
Min Order Qty
1
Anti-Static
No
Element Series
HC9600
Family
Ultipor III
Filter Media
Wire Mesh
Filter Removal Rating (μm)
50 µm
Nominal Length (Imperial)
13 in
See All Attributes

Ultipor III Wire Mesh 50 micron Nitrile 8in 20.32cm

Product ID: HC9600EOM8H
Unit of Measure
12/EA
Min Order Qty
12
Anti-Static
No
Element Series
HC9600
Family
Ultipor III
Filter Media
Wire Mesh
Filter Removal Rating (μm)
50 µm
Nominal Length (Imperial)
8 in
See All Attributes

Ultipor® I Cleanable Filter Element

Product ID: HC9600EOS13H
Unit of Measure
1/EA
Min Order Qty
1
Anti-Static
No
Element Series
HC9600
Family
Ultipor III
Filter Media
Wire Mesh
Filter Removal Rating (μm)
100 µm
Nominal Length (Imperial)
13 in
See All Attributes

Ultipor III Wire Mesh 50 micron Nitrile 16in 40.64cm

Product ID: HC9600EOM16H
Unit of Measure
1/EA
Min Order Qty
1
Anti-Static
No
Element Series
HC9600
Family
Ultipor III
Filter Media
Wire Mesh
Filter Removal Rating (μm)
50 µm
Nominal Length (Imperial)
16 in
See All Attributes

Ultipor III Wire Mesh 225 micron Fluorocarbon 13in 33.02cm

Product ID: HC9600EOT13Z
Unit of Measure
1/EA
Min Order Qty
1
Anti-Static
No
Element Series
HC9600
Family
Ultipor III
Filter Media
Wire Mesh
Filter Removal Rating (μm)
225 µm
Nominal Length (Imperial)
13 in
See All Attributes

This product is currently not available. Please contact us for more information.

Description

Why Choose Profile II RFN Series depth filter cartridges?

 

The Profile II RFN elements have an absolute rated downstream section leading to 99.98% efficiency in liquid and a continuously profiled pore size upstream section for increased service life. 

Product Highlights

  • All nylon filter medium with glass-filled polypropylene cores
  • Increased service life

Applications/Uses

The Profile II RFN filter has numerous applications in a broad range of industries such as chemical, petrochemical, pharmaceutical, paint, resin coating, food, beverage and cosmetics.

 

 

Chemicals and Polymer:

  • Chemicals - Final product (liquid), raw material (gas, air, liquid) and intermediate product (other)
  • Petrochemicals (Amine, Benfield, other solvent loops)
  • Polymer - Carbon fiber, nylon and polyurethane production

Oil and Gas:

  • Upstream Injection Water & SRU
  • Midstream LNG acid gas
  • Midstream glycol filtration
  • Midstream Process Water
  • Refinery Amine Systems

Specifications

 

The recommended maximum pressure differential for the standard RFN Series filters is 75 psi up to 86 °F (30 °C), 50 psi up to 158 °F (70 °C), and 35 psi up to 180 °F (82 °C). For the GN Series filters with glass filled nylon cores, recommended maximum pressure differential is 90 psi up to 86 °F (30 °C), 80 psi up to 158 °F (70 °C), 70 psi up to 212 °F (100 °C), and 50 psi up to 300 °F (150 °C).

 

If the fluid filtered is compatible with polypropylene and temperature below 194 °F (90 °C), Profile II RF Polypropylene Series elements, described in Data Sheet E1 and Bulletin PRO 400, may be suitable. Pall Corporation’s Scientific and Laboratory Services group will supply compatibility information for both nylon and polypropylene upon request.

 

Cartridge Grade Grade Removal Rating Clean Pressure Drop Typical Aqueous Flow (GPM/10" Cartridge)
  Liquid Service Liquid Service Gaseous Service  
  Rating in μm at % Efficiency Aqueous Pressure Drop (psi/gpm)2 CFM of Air per PSI per 10" Cartridge3  
  90% 99% 99.9% 99.98%      
050 2.0 3.0 4 5 0.8 11 3 - 8
100 6.5 7.5 9 10 0.3 29 6 - 15
200 10 14 18 20 0.10 75 10 - 15
400  20 30 35 40 0.05 207 10 - 15
700 32 50 701 - <0.05 415 10 - 15

 

1 Extrapolated values.

2 Pressure drop in PSI per GPM for a single 10″ module. For multiple elements, divide by number of modules. For fluids other than water, multiply by viscosity in centipoise.

3 For longer modules, increase the flow rates listed in proportion. The flow rates listed do not take into account pressure losses due to flow in the internal diameter of the element, which becomes significant above about 40 to 60 cfm.

Documents

Data Sheets

  • Profile® II RFN Series Filter Elements

    Select Language :