Profile® II RFN Nylon Depth Filter – Gas, Liquid Filter Cartridges

For Liquid and Gas Applications 

Profile II RFN Series depth filter cartridges are for liquid and gas applications such as chemical, petrochemical, paint, resin coating, and food and beverage. They are comprised of an all-nylon filter medium with glass-filled polypropylene cores and available with glass-filled nylon cores for use with xylene, toluene, or other aromatics and high temperatures.  There is no binder resin as the fibers are “bonded” by intertwining during the manufacturing process.  As a result, these depth filter cartridges show no media migration.

Order Products

Gasket / O-Ring Material

Fluorocarbon Elastomer

Poly-Fine® II, Filter Cartridges, Removal Rating 0.25 μm, Polypropylene, Length 30 Inches, Fluorocarbon Elastomer, SOE fin end external 226 O-rings product photo
Unit of Measure
1/EA
Min Order Qty
1
Micron
0.25 µm
Poly-Fine® II, Filter Cartridges, Removal Rating 0.8 μm, Polypropylene, Length 40 Inches, Fluorocarbon Elastomer, SOE fin end external 222 O-rings product photo
Unit of Measure
1/EA
Min Order Qty
1
Micron
0.8 µm
Poly-Fine® II, Filter Cartridges, Removal Rating 10 μm, Polypropylene, Length 30 Inches, Fluorocarbon Elastomer, SOE fin end external 225 O-ring product photo

Poly-Fine® II, Filter Cartridges, Removal Rating 10 μm, Polypropylene, Length 30 Inches, Fluorocarbon Elastomer, SOE fin end external 225 O-ring

Product ID: PFT1030UVM22LGID
Unit of Measure
1/EA
Min Order Qty
1
Micron
10 µm
Poly-Fine® II, Filter Cartridges, Removal Rating 2 μm, Polypropylene, Length 20 Inches, Fluorocarbon Elastomer product photo

Poly-Fine® II, Filter Cartridges, Removal Rating 2 μm, Polypropylene, Length 20 Inches, Fluorocarbon Elastomer

Product ID: PFT220UVM3
Unit of Measure
1/EA
Min Order Qty
1
Micron
2 µm

Poly-Fine® II Filter Cartridges, Removal Rating 0.25 μm, Length 29.25 inches

Product ID: QMPT002292UV
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
0.25 µm
Cartridge Length (Imperial)
29.25 in
Cartridge Length (Metric)
743 mm
Cartridge Length (Metric)
74.3 cm
Gasket / O-Ring Material
Fluorocarbon Elastomer
End Configuration Code
Blank
See All Attributes
DFT Classic®, Filter Cartridges, Removal Rating 1 μm, Length 30 Inches, Polypropylene, FluorocarbonElastomer product photo

DFT Classic®, Filter Cartridges, Removal Rating 1 μm, Length 30 Inches, Polypropylene, FluorocarbonElastomer

Product ID: C001AW30UVM3
Unit of Measure
10/EA
Min Order Qty
10
Packaging
Bulk
See All Attributes

Poly-Fine® II, Filter Cartridges, Removal Rating 30 μm, Polypropylene, Length 10 Inches, Fluorocarbon Elastomer, SOE fin end external 222 O-rings

Product ID: PFT3010UVM8
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
30 µm
Membrane Material
Polypropylene
Industry-Specific Certification
General Use
Cartridge Length (Imperial)
10 in
Cartridge Length (Metric)
254 mm
Cartridge Length (Metric)
25.4 cm
See All Attributes

Profile® UP Filter Cartridges, Removal Rating 2 μm, Length 20 inches, FluorocarbonElastomer

Product ID: AB2UY0207H
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
2 µm
Cartridge Length (Imperial)
20 in
Cartridge Length (Metric)
508 mm
Cartridge Length (Metric)
50.8 cm
Gasket / O-Ring Material
Fluorocarbon Elastomer
Cartridge Outer Diameter (OD) (Imperial)
2.75 in
See All Attributes

Profile® UP, Filter Cartridges, Removal Rating 2 μm , Length 30 Inches, FluorocarbonElastomer

Product ID: AB3UY0207H
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
2 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
30 in
Cartridge Length (Metric)
762 mm
Cartridge Length (Metric)
76.2 cm
Gasket / O-Ring Material
Fluorocarbon Elastomer
See All Attributes

Profile® UP, Filter Cartridges, Removal Rating 10 μm, , Length 30 Inches

Product ID: AB3UY1003H
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
10 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
30 in
Cartridge Length (Metric)
762 mm
Cartridge Length (Metric)
76.2 cm
Gasket / O-Ring Material
Fluorocarbon Elastomer
See All Attributes

Profile® II, Filter Cartridges, Polypropylene, Length 30 Inches, Fluorocarbon Elastomer

Product ID: AB3Y40018H
Unit of Measure
24/EA
Min Order Qty
24
Membrane Material
Polypropylene
Cartridge Length (Imperial)
30 in
Cartridge Length (Metric)
753 mm
Cartridge Length (Metric)
75.3 cm
Gasket / O-Ring Material
Fluorocarbon Elastomer
Cartridge Outer Diameter (OD) (Imperial)
2.75 in
See All Attributes

Poly-Fine® ARD, Filter Cartridges, Removal Rating 1 μm, Polypropylene, Length 30 Inches, Fluorocarbon Elastomer

Product ID: ARD130UVM7
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
1 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
30 in
Cartridge Length (Metric)
762 mm
Cartridge Length (Metric)
76.2 cm
Gasket / O-Ring Material
Fluorocarbon Elastomer
See All Attributes

Description

Why Choose Profile II RFN Series depth filter cartridges?

 

The Profile II RFN elements have an absolute rated downstream section leading to 99.98% efficiency in liquid and a continuously profiled pore size upstream section for increased service life. 

Product Highlights

  • All nylon filter medium with glass-filled polypropylene cores
  • Increased service life

Applications/Uses

The Profile II RFN filter has numerous applications in a broad range of industries such as chemical, petrochemical, pharmaceutical, paint, resin coating, food, beverage and cosmetics.

 

 

Chemicals and Polymer:

  • Chemicals - Final product (liquid), raw material (gas, air, liquid) and intermediate product (other)
  • Petrochemicals (Amine, Benfield, other solvent loops)
  • Polymer - Carbon fiber, nylon and polyurethane production

Oil and Gas:

  • Upstream Injection Water & SRU
  • Midstream LNG acid gas
  • Midstream glycol filtration
  • Midstream Process Water
  • Refinery Amine Systems

Specifications

 

The recommended maximum pressure differential for the standard RFN Series filters is 75 psi up to 86 °F (30 °C), 50 psi up to 158 °F (70 °C), and 35 psi up to 180 °F (82 °C). For the GN Series filters with glass filled nylon cores, recommended maximum pressure differential is 90 psi up to 86 °F (30 °C), 80 psi up to 158 °F (70 °C), 70 psi up to 212 °F (100 °C), and 50 psi up to 300 °F (150 °C).

 

If the fluid filtered is compatible with polypropylene and temperature below 194 °F (90 °C), Profile II RF Polypropylene Series elements, described in Data Sheet E1 and Bulletin PRO 400, may be suitable. Pall Corporation’s Scientific and Laboratory Services group will supply compatibility information for both nylon and polypropylene upon request.

 

Cartridge Grade Grade Removal Rating Clean Pressure Drop Typical Aqueous Flow (GPM/10" Cartridge)
  Liquid Service Liquid Service Gaseous Service  
  Rating in μm at % Efficiency Aqueous Pressure Drop (psi/gpm)2 CFM of Air per PSI per 10" Cartridge3  
  90% 99% 99.9% 99.98%      
050 2.0 3.0 4 5 0.8 11 3 - 8
100 6.5 7.5 9 10 0.3 29 6 - 15
200 10 14 18 20 0.10 75 10 - 15
400  20 30 35 40 0.05 207 10 - 15
700 32 50 701 - <0.05 415 10 - 15

 

1 Extrapolated values.

2 Pressure drop in PSI per GPM for a single 10″ module. For multiple elements, divide by number of modules. For fluids other than water, multiply by viscosity in centipoise.

3 For longer modules, increase the flow rates listed in proportion. The flow rates listed do not take into account pressure losses due to flow in the internal diameter of the element, which becomes significant above about 40 to 60 cfm.

Documents

Data Sheets

  • Profile® II RFN Series Filter Elements

    Select Language :