Profile® II RFN Nylon Depth Filter – Gas, Liquid Filter Cartridges

For Liquid and Gas Applications 

Profile II RFN Series depth filter cartridges are for liquid and gas applications such as chemical, petrochemical, paint, resin coating, and food and beverage. They are comprised of an all-nylon filter medium with glass-filled polypropylene cores and available with glass-filled nylon cores for use with xylene, toluene, or other aromatics and high temperatures.  There is no binder resin as the fibers are “bonded” by intertwining during the manufacturing process.  As a result, these depth filter cartridges show no media migration.

Order Products

Gasket / O-Ring Material

NA

Nexis® A Series Filter Cartridges, Removal Rating 1 μm, Polypropylene, DOE industrial (no end caps)

Product ID: NXA1295U
Unit of Measure
24/EA
Min Order Qty
24
Removal Rating
1 µm
Membrane Material
Polypropylene
Gasket / O-Ring Material
NA
End Configuration Code
BLANK
End Configuration
BLANK - DOE industrial (no end caps)
Cartridge Type
NXA
See All Attributes

Nexis® A Series Filter Cartridges, Removal Rating 3 μm, Polypropylene, Length 9.75 inches

Product ID: NXA3975U
Unit of Measure
30/EA
Min Order Qty
30
Removal Rating
3 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
9.75 in
Cartridge Length (Metric)
248 mm
Cartridge Length (Metric)
24.8 cm
Gasket / O-Ring Material
NA
See All Attributes

Nexis® T Filter Cartridges, Removal Rating 100 μm, Polypropylene, Length 29.25 inches

Product ID: NXT1002925U
Unit of Measure
10/EA
Min Order Qty
10
Removal Rating
100 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
29.25 in
Cartridge Length (Metric)
743 mm
Cartridge Length (Metric)
74.3 cm
Gasket / O-Ring Material
NA
See All Attributes

Nexis® T Filter Cartridges, Removal Rating 10 μm, Polypropylene, Length 9.75 inches, DOE industrial (no end caps)

Product ID: NXT10975U729
Unit of Measure
30/EA
Min Order Qty
30
Removal Rating
10 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
9.75 in
Cartridge Length (Metric)
248 mm
Cartridge Length (Metric)
24.8 cm
Gasket / O-Ring Material
NA
See All Attributes

Nexis® T Filter Cartridges, Removal Rating 15 μm, Polypropylene, Length 29.25 inches

Product ID: NXT152925U
Unit of Measure
20/EA
Min Order Qty
20
Removal Rating
15 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
29.25 in
Cartridge Length (Metric)
743 mm
Cartridge Length (Metric)
74.3 cm
Gasket / O-Ring Material
NA
See All Attributes

Nexis® T Filter Cartridges, Removal Rating 1 μm, Polypropylene, Length 9.75 inches

Product ID: NXT1975U
Unit of Measure
30/EA
Min Order Qty
30
Removal Rating
1 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
9.75 in
Cartridge Length (Metric)
248 mm
Cartridge Length (Metric)
24.8 cm
Gasket / O-Ring Material
NA
See All Attributes
Nexis® T Filter Cartridges, Removal Rating 3 μm, Polypropylene, Length 10 inches product photo

Nexis® T Filter Cartridges, Removal Rating 3 μm, Polypropylene, Length 10 inches

Product ID: NXT310U
Unit of Measure
30/EA
Min Order Qty
30
Micron
3 micron
E010AW30S-EC1S product photo

E010AW30S-EC1S

Product ID: E010AW30SEC1S
Unit of Measure
10/EA
Min Order Qty
10
Packaging
Bulk
See All Attributes
E025AW30S-EC1S product photo

E025AW30S-EC1S

Product ID: E025AW30SEC1S
Unit of Measure
10/EA
Min Order Qty
10
Packaging
Bulk
See All Attributes
E050AW30S-EC1S product photo

E050AW30S-EC1S

Product ID: E050AW30SEC1S
Unit of Measure
10/EA
Min Order Qty
10
Packaging
Bulk
See All Attributes
U030AW30U-EC1U product photo

U030AW30U-EC1U

Product ID: U030AW30UEC1U
Unit of Measure
10/EA
Min Order Qty
10
Packaging
Bulk
See All Attributes
C003AW40A-1PK product photo

C003AW40A-1PK

Product ID: C003AW40A1PK
Unit of Measure
10/EA
Min Order Qty
10
Packaging
Individually wrapped
See All Attributes

Description

Why Choose Profile II RFN Series depth filter cartridges?

 

The Profile II RFN elements have an absolute rated downstream section leading to 99.98% efficiency in liquid and a continuously profiled pore size upstream section for increased service life. 

Product Highlights

  • All nylon filter medium with glass-filled polypropylene cores
  • Increased service life

Applications/Uses

The Profile II RFN filter has numerous applications in a broad range of industries such as chemical, petrochemical, pharmaceutical, paint, resin coating, food, beverage and cosmetics.

 

 

Chemicals and Polymer:

  • Chemicals - Final product (liquid), raw material (gas, air, liquid) and intermediate product (other)
  • Petrochemicals (Amine, Benfield, other solvent loops)
  • Polymer - Carbon fiber, nylon and polyurethane production

Oil and Gas:

  • Upstream Injection Water & SRU
  • Midstream LNG acid gas
  • Midstream glycol filtration
  • Midstream Process Water
  • Refinery Amine Systems

Specifications

 

The recommended maximum pressure differential for the standard RFN Series filters is 75 psi up to 86 °F (30 °C), 50 psi up to 158 °F (70 °C), and 35 psi up to 180 °F (82 °C). For the GN Series filters with glass filled nylon cores, recommended maximum pressure differential is 90 psi up to 86 °F (30 °C), 80 psi up to 158 °F (70 °C), 70 psi up to 212 °F (100 °C), and 50 psi up to 300 °F (150 °C).

 

If the fluid filtered is compatible with polypropylene and temperature below 194 °F (90 °C), Profile II RF Polypropylene Series elements, described in Data Sheet E1 and Bulletin PRO 400, may be suitable. Pall Corporation’s Scientific and Laboratory Services group will supply compatibility information for both nylon and polypropylene upon request.

 

Cartridge Grade Grade Removal Rating Clean Pressure Drop Typical Aqueous Flow (GPM/10" Cartridge)
  Liquid Service Liquid Service Gaseous Service  
  Rating in μm at % Efficiency Aqueous Pressure Drop (psi/gpm)2 CFM of Air per PSI per 10" Cartridge3  
  90% 99% 99.9% 99.98%      
050 2.0 3.0 4 5 0.8 11 3 - 8
100 6.5 7.5 9 10 0.3 29 6 - 15
200 10 14 18 20 0.10 75 10 - 15
400  20 30 35 40 0.05 207 10 - 15
700 32 50 701 - <0.05 415 10 - 15

 

1 Extrapolated values.

2 Pressure drop in PSI per GPM for a single 10″ module. For multiple elements, divide by number of modules. For fluids other than water, multiply by viscosity in centipoise.

3 For longer modules, increase the flow rates listed in proportion. The flow rates listed do not take into account pressure losses due to flow in the internal diameter of the element, which becomes significant above about 40 to 60 cfm.

Documents

Data Sheets

  • Profile® II RFN Series Filter Elements

    Select Language :