Profile® II RFN Nylon Depth Filter – Gas, Liquid Filter Cartridges

For Liquid and Gas Applications 

Profile II RFN Series depth filter cartridges are for liquid and gas applications such as chemical, petrochemical, paint, resin coating, and food and beverage. They are comprised of an all-nylon filter medium with glass-filled polypropylene cores and available with glass-filled nylon cores for use with xylene, toluene, or other aromatics and high temperatures.  There is no binder resin as the fibers are “bonded” by intertwining during the manufacturing process.  As a result, these depth filter cartridges show no media migration.

Order Products

Availability

In Stock

O-RING FLCB ORH237 KBN

Product ID: 1196237
Unit of Measure
1/EA
Min Order Qty
1

PLUG BLD SAE HX HD-4

Product ID: 1128258
Unit of Measure
1/EA
Min Order Qty
1

Seitz® HS Series Depth Filter sheet, HS 2000 600x612

Product ID: 1432058
Unit of Measure
50/EA
Min Order Qty
50
Filter Media
Kieselguhr, Perlite and Cellulose Fibers
Filter Area (Imperial)
3.95 ft²
Filter Area (Metric)
0.37 m²
Hot Water Sanitization
85 °C
Recommended max.dp
3 bar
Size (Imperial)
23.62 x 24.09 in
See All Attributes

Seitz® HS Series Depth Filter sheet, HS 400 600x612

Product ID: 1430458
Unit of Measure
50/EA
Min Order Qty
50
Filter Media
Kieselguhr, Perlite and Cellulose Fibers
Filter Area (Imperial)
3.95 ft²
Filter Area (Metric)
0.37 m²
Hot Water Sanitization
85 °C
Recommended max.dp
1.5 bar
Size (Imperial)
23.62 x 24.09 in
See All Attributes

SUPRAdisc SD II EK 200XEK0C232SPW

Product ID: 7007869
Unit of Measure
1/EA
Min Order Qty
1
1. Recommended Max. Backpressure During Backwash
0.5 bar
2. Recommended Max. Backpressure During Backwash
7.25 psid
Adaptor Type
Double Open End, Flat Gasket
Core Drainage Discs
Polypropylene
Diameter (Imperial)
12 in
Diameter (Metric)
287 mm
See All Attributes

AB05U200Z7H4

Product ID: AB05U200Z7H4
Unit of Measure
1/EA
Min Order Qty
1

Ultipor® GF Plus, Filter Cartridges, Length 30 Inches, silicone

Product ID: AB3U220Z7H4
Unit of Measure
1/EA
Min Order Qty
1
Membrane Material
Polypropylene
Filter Cartridge Style
Code 7
Cartridge Length (Imperial)
30 in
Cartridge Length (Metric)
762 mm
Cartridge Length (Metric)
76.2 cm
Gasket / O-Ring Material
Silicone
See All Attributes

Claris® Filter Cartridges, Removal Rating 20 μm, Polypropylene, Length 40 inches, Nitrile, SOE flat closed end external 222 O-ring

Product ID: CLR2040M18N
Unit of Measure
12/EA
Min Order Qty
12
Removal Rating
20 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
40 in
Cartridge Length (Metric)
1016 mm
Cartridge Length (Metric)
101.6 cm
Gasket / O-Ring Material
Nitrile
See All Attributes
Claris® Filter Cartridges, Removal Rating 50 μm, Polypropylene, Length 40 inches product photo

Claris® Filter Cartridges, Removal Rating 50 μm, Polypropylene, Length 40 inches

Product ID: CLR5040
Unit of Measure
12/EA
Min Order Qty
12
Length
102 cm / 40 in
Micron
50 micron

Duo-Fine® , Filter Cartridges, Removal Rating 10 μm, Length 30 Inches, Nitrile, DOE 2.54 cm (1 in) extended core

Product ID: DFN1030AN1X
Unit of Measure
12/EA
Min Order Qty
12
Removal Rating
10 µm
Cartridge Length (Imperial)
30 in
Cartridge Length (Metric)
762 mm
Cartridge Length (Metric)
76.2 cm
Gasket / O-Ring Material
Nitrile
End Configuration Code
1X
See All Attributes

Supralon™ Lube and Hydraulic Elements, Removal Rating 3 μm, GlassFiber, Length 39 Inches

Product ID: EB1401K01039Z
Unit of Measure
1/EA
Min Order Qty
1
Anti-Static
No
Beta Rating
BETA 2000
Family
Supralon
Filter Media
Glass Fiber
Filter Removal Rating
3 micron (Beta 2000)
Filter Removal Rating (μm)
3 µm
See All Attributes

O-RING VITN ORH-908 FTM

Product ID: F1124508
Unit of Measure
1/EA
Min Order Qty
1

Description

Why Choose Profile II RFN Series depth filter cartridges?

 

The Profile II RFN elements have an absolute rated downstream section leading to 99.98% efficiency in liquid and a continuously profiled pore size upstream section for increased service life. 

Product Highlights

  • All nylon filter medium with glass-filled polypropylene cores
  • Increased service life

Applications/Uses

The Profile II RFN filter has numerous applications in a broad range of industries such as chemical, petrochemical, pharmaceutical, paint, resin coating, food, beverage and cosmetics.

 

 

Chemicals and Polymer:

  • Chemicals - Final product (liquid), raw material (gas, air, liquid) and intermediate product (other)
  • Petrochemicals (Amine, Benfield, other solvent loops)
  • Polymer - Carbon fiber, nylon and polyurethane production

Oil and Gas:

  • Upstream Injection Water & SRU
  • Midstream LNG acid gas
  • Midstream glycol filtration
  • Midstream Process Water
  • Refinery Amine Systems

Specifications

 

The recommended maximum pressure differential for the standard RFN Series filters is 75 psi up to 86 °F (30 °C), 50 psi up to 158 °F (70 °C), and 35 psi up to 180 °F (82 °C). For the GN Series filters with glass filled nylon cores, recommended maximum pressure differential is 90 psi up to 86 °F (30 °C), 80 psi up to 158 °F (70 °C), 70 psi up to 212 °F (100 °C), and 50 psi up to 300 °F (150 °C).

 

If the fluid filtered is compatible with polypropylene and temperature below 194 °F (90 °C), Profile II RF Polypropylene Series elements, described in Data Sheet E1 and Bulletin PRO 400, may be suitable. Pall Corporation’s Scientific and Laboratory Services group will supply compatibility information for both nylon and polypropylene upon request.

 

Cartridge Grade Grade Removal Rating Clean Pressure Drop Typical Aqueous Flow (GPM/10" Cartridge)
  Liquid Service Liquid Service Gaseous Service  
  Rating in μm at % Efficiency Aqueous Pressure Drop (psi/gpm)2 CFM of Air per PSI per 10" Cartridge3  
  90% 99% 99.9% 99.98%      
050 2.0 3.0 4 5 0.8 11 3 - 8
100 6.5 7.5 9 10 0.3 29 6 - 15
200 10 14 18 20 0.10 75 10 - 15
400  20 30 35 40 0.05 207 10 - 15
700 32 50 701 - <0.05 415 10 - 15

 

1 Extrapolated values.

2 Pressure drop in PSI per GPM for a single 10″ module. For multiple elements, divide by number of modules. For fluids other than water, multiply by viscosity in centipoise.

3 For longer modules, increase the flow rates listed in proportion. The flow rates listed do not take into account pressure losses due to flow in the internal diameter of the element, which becomes significant above about 40 to 60 cfm.

Documents

Data Sheets

  • Profile® II RFN Series Filter Elements

    Select Language :