Profile® II RFN Nylon Depth Filter – Gas, Liquid Filter Cartridges

For Liquid and Gas Applications 

Profile II RFN Series depth filter cartridges are for liquid and gas applications such as chemical, petrochemical, paint, resin coating, and food and beverage. They are comprised of an all-nylon filter medium with glass-filled polypropylene cores and available with glass-filled nylon cores for use with xylene, toluene, or other aromatics and high temperatures.  There is no binder resin as the fibers are “bonded” by intertwining during the manufacturing process.  As a result, these depth filter cartridges show no media migration.

Order Products

Family

Athalon

Athalon Glass Fiber 25 micron (Beta 2000) Fluorocarbon 13in 33.02cm

Product ID: RR000097951
Unit of Measure
15/EA
Min Order Qty
15
Anti-Static
Yes
Beta Rating
BETA 2000
Element Series
UE210
Family
Athalon
Filter Media
Glass Fiber
Filter Removal Rating (μm)
25 µm
See All Attributes

Athalon Glass Fiber 12 micron (Beta 2000) Nitrile 13in 33.02cm

Product ID: UA159AS13H
Unit of Measure
6/EA
Min Order Qty
6
Anti-Static
Yes
Beta Rating
BETA 2000
Element Series
UA159
Family
Athalon
Filter Media
Glass Fiber
Filter Removal Rating (μm)
12 µm
See All Attributes

Athalon Anti-Static Glass Fiber 7 micron (Beta 2000) Nitrile 3in 7.62cm length

Product ID: UE209AN03H
Unit of Measure
6/EA
Min Order Qty
6
Anti-Static
Yes
Beta Rating
BETA 2000
Element Series
UE209
Family
Athalon
Filter Media
Glass Fiber
Filter Removal Rating
7 micron (Beta 2000)
See All Attributes

Athalon Glass Fiber 7 micron (Beta 2000) Nitrile 7in 17.78cm

Product ID: UE209AN07H
Unit of Measure
6/EA
Min Order Qty
6
Anti-Static
Yes
Beta Rating
BETA 2000
Element Series
UE209
Family
Athalon
Filter Media
Glass Fiber
Filter Removal Rating (μm)
7 µm
See All Attributes

ELEMENT ULTIPLEAT SRT

Product ID: UE209AN03Z
Unit of Measure
6/EA
Min Order Qty
6
Anti-Static
Yes
Beta Rating
BETA 2000
Element Series
UE209
Family
Athalon
Filter Media
Glass Fiber
Filter Removal Rating (μm)
7 µm
See All Attributes

Athalon Glass Fiber 7 micron (Beta 2000) Nitrile 3in 7.62cm

Product ID: UE209AN03HYT34
Unit of Measure
16/EA
Min Order Qty
16
Anti-Static
Yes
Beta Rating
BETA 2000
Element Series
UE209
Family
Athalon
Filter Media
Glass Fiber
Filter Removal Rating (μm)
7 µm
See All Attributes

UE209AS07J

Product ID: UE209AS07J
Unit of Measure
16/EA
Min Order Qty
16
Anti-Static
Yes
Beta Rating
BETA 2000
Element Series
UE209
Family
Athalon
Filter Media
Glass Fiber
Filter Removal Rating (μm)
12 µm
See All Attributes

UE209AP07Z ELEMENT

Product ID: UE209AP07Z
Unit of Measure
6/EA
Min Order Qty
6
Anti-Static
Yes
Beta Rating
BETA 2000
Element Series
UE209
Family
Athalon
Filter Media
Glass Fiber
Filter Removal Rating
5 micron (Beta 2000)
See All Attributes

Athalon Glass Fiber 5 micron (Beta 2000) Nitrile 7in 17.78cm

Product ID: UE209AP07H
Unit of Measure
16/EA
Min Order Qty
16
Anti-Static
Yes
Beta Rating
BETA 2000
Element Series
UE209
Family
Athalon
Filter Media
Glass Fiber
Filter Removal Rating (μm)
5 µm
See All Attributes

UE209AT03H - REP BY UE209AT03Z

Product ID: UE209AT03H
Unit of Measure
16/EA
Min Order Qty
16
Anti-Static
Yes
Beta Rating
BETA 2000
Element Series
UE209
Family
Athalon
Filter Media
Glass Fiber
Filter Removal Rating
22 micron, Beta 2000
See All Attributes

Element 209AS03H SRT

Product ID: UE209AS03H
Unit of Measure
16/EA
Min Order Qty
16
Anti-Static
Yes
Beta Rating
BETA 2000
Element Series
UE209
Family
Athalon
Filter Media
Glass Fiber
Filter Removal Rating (μm)
12 µm
See All Attributes

UE209AT07J

Product ID: UE209AT07J
Unit of Measure
16/EA
Min Order Qty
16
Anti-Static
Yes
Beta Rating
BETA 2000
Element Series
UE209
Family
Athalon
Filter Media
Glass Fiber
Filter Removal Rating (μm)
25 µm
See All Attributes

Description

Why Choose Profile II RFN Series depth filter cartridges?

 

The Profile II RFN elements have an absolute rated downstream section leading to 99.98% efficiency in liquid and a continuously profiled pore size upstream section for increased service life. 

Product Highlights

  • All nylon filter medium with glass-filled polypropylene cores
  • Increased service life

Applications/Uses

The Profile II RFN filter has numerous applications in a broad range of industries such as chemical, petrochemical, pharmaceutical, paint, resin coating, food, beverage and cosmetics.

 

 

Chemicals and Polymer:

  • Chemicals - Final product (liquid), raw material (gas, air, liquid) and intermediate product (other)
  • Petrochemicals (Amine, Benfield, other solvent loops)
  • Polymer - Carbon fiber, nylon and polyurethane production

Oil and Gas:

  • Upstream Injection Water & SRU
  • Midstream LNG acid gas
  • Midstream glycol filtration
  • Midstream Process Water
  • Refinery Amine Systems

Specifications

 

The recommended maximum pressure differential for the standard RFN Series filters is 75 psi up to 86 °F (30 °C), 50 psi up to 158 °F (70 °C), and 35 psi up to 180 °F (82 °C). For the GN Series filters with glass filled nylon cores, recommended maximum pressure differential is 90 psi up to 86 °F (30 °C), 80 psi up to 158 °F (70 °C), 70 psi up to 212 °F (100 °C), and 50 psi up to 300 °F (150 °C).

 

If the fluid filtered is compatible with polypropylene and temperature below 194 °F (90 °C), Profile II RF Polypropylene Series elements, described in Data Sheet E1 and Bulletin PRO 400, may be suitable. Pall Corporation’s Scientific and Laboratory Services group will supply compatibility information for both nylon and polypropylene upon request.

 

Cartridge Grade Grade Removal Rating Clean Pressure Drop Typical Aqueous Flow (GPM/10" Cartridge)
  Liquid Service Liquid Service Gaseous Service  
  Rating in μm at % Efficiency Aqueous Pressure Drop (psi/gpm)2 CFM of Air per PSI per 10" Cartridge3  
  90% 99% 99.9% 99.98%      
050 2.0 3.0 4 5 0.8 11 3 - 8
100 6.5 7.5 9 10 0.3 29 6 - 15
200 10 14 18 20 0.10 75 10 - 15
400  20 30 35 40 0.05 207 10 - 15
700 32 50 701 - <0.05 415 10 - 15

 

1 Extrapolated values.

2 Pressure drop in PSI per GPM for a single 10″ module. For multiple elements, divide by number of modules. For fluids other than water, multiply by viscosity in centipoise.

3 For longer modules, increase the flow rates listed in proportion. The flow rates listed do not take into account pressure losses due to flow in the internal diameter of the element, which becomes significant above about 40 to 60 cfm.

Documents

Data Sheets

  • Profile® II RFN Series Filter Elements

    Select Language :