Poly-Fine® XLD Pleated Depth Filter Cartridges

For High-Efficiency Filtration

Poly-Fine XLD pleated depth filter cartridges are an innovative synthesis of depth and pleated filtration technologies that offer highly consistent, reproducible performance. The Poly-Fine XLD series also offers a special filter for inkjet ink formulations.

Order Products

Industries

Industrial Manufacturing

Filter Media

Polypropylene

Nexis® A Series Filter Cartridges, Removal Rating 3 μm, Polypropylene, Length 9.75 inches

Product ID: NXA3975U
Unit of Measure
30/EA
Min Order Qty
30
Removal Rating
3 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
9.75 in
Cartridge Length (Metric)
248 mm
Cartridge Length (Metric)
24.8 cm
Gasket / O-Ring Material
NA
See All Attributes

Nexis® A Series Filter Cartridges, Removal Rating 70 μm, Polypropylene, Length 30 inches, Nitrile, SOE flat closed end external 222 O-ring

Product ID: NXA7030UM18N
Unit of Measure
12/EA
Min Order Qty
12
Removal Rating
70 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
30 in
Cartridge Length (Metric)
762 mm
Cartridge Length (Metric)
76.2 cm
Gasket / O-Ring Material
Nitrile
See All Attributes

Nexis® T Filter Cartridges, Removal Rating 0.5 μm, Polypropylene, Length 30 inches, silicone, DOE with elastomer gasket seals and end caps

Product ID: NXT0530UDOES
Unit of Measure
12/EA
Min Order Qty
12
Removal Rating
0.5 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
30 in
Cartridge Length (Metric)
762 mm
Cartridge Length (Metric)
76.2 cm
Gasket / O-Ring Material
Silicone
See All Attributes

Nexis® T Filter Cartridges, Removal Rating 0.5 μm, Polypropylene, Length 30 inches, silicone, SOE fin end external 222 O-rings

Product ID: NXT0530UM8S
Unit of Measure
12/EA
Min Order Qty
12
Removal Rating
0.5 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
30 in
Cartridge Length (Metric)
762 mm
Cartridge Length (Metric)
76.2 cm
Gasket / O-Ring Material
Silicone
See All Attributes

Nexis® T Filter Cartridges, Removal Rating 100 μm, Polypropylene, Length 29.25 inches

Product ID: NXT1002925U
Unit of Measure
10/EA
Min Order Qty
10
Removal Rating
100 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
29.25 in
Cartridge Length (Metric)
743 mm
Cartridge Length (Metric)
74.3 cm
Gasket / O-Ring Material
NA
See All Attributes

Nexis® T Filter Cartridges, Removal Rating 10 μm, Polypropylene, Length 9.75 inches, DOE industrial (no end caps)

Product ID: NXT10975U729
Unit of Measure
30/EA
Min Order Qty
30
Removal Rating
10 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
9.75 in
Cartridge Length (Metric)
248 mm
Cartridge Length (Metric)
24.8 cm
Gasket / O-Ring Material
NA
See All Attributes

Nexis® T Filter Cartridges, Removal Rating 15 μm, Polypropylene, Length 29.25 inches

Product ID: NXT152925U
Unit of Measure
20/EA
Min Order Qty
20
Removal Rating
15 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
29.25 in
Cartridge Length (Metric)
743 mm
Cartridge Length (Metric)
74.3 cm
Gasket / O-Ring Material
NA
See All Attributes

Nexis® T Filter Cartridges, Removal Rating 75 μm, Polypropylene, Length 10 inches, EPDM, DOE with elastomer gasket seals and end caps

Product ID: NXT7510UDOEE
Unit of Measure
30/EA
Min Order Qty
30
Removal Rating
75 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
10 in
Cartridge Length (Metric)
254 mm
Cartridge Length (Metric)
25.4 cm
Gasket / O-Ring Material
EPDM
See All Attributes
Poly-Fine® II, Filter Cartridges, Removal Rating 0.25 μm, Polypropylene, Length 40 Inches, Nitrile product photo

Poly-Fine® II, Filter Cartridges, Removal Rating 0.25 μm, Polypropylene, Length 40 Inches, Nitrile

Product ID: PFT02540UN
Unit of Measure
1/EA
Min Order Qty
1
Micron
0.25 µm
Poly-Fine® II, Filter Cartridges, Removal Rating 0.25 μm, Polypropylene, Length 40 Inches, silicone, SOE fin end external 222 O-rings product photo

Poly-Fine® II, Filter Cartridges, Removal Rating 0.25 μm, Polypropylene, Length 40 Inches, silicone, SOE fin end external 222 O-rings

Product ID: PFT02540USM8
Unit of Measure
1/EA
Min Order Qty
1
Micron
0.25 µm
Poly-Fine® II, Filter Cartridges, Removal Rating 0.45 μm, Polypropylene, Length 10 Inches, Expanded PTFE gaskets FEP encapsulated silicone Orings, DOE industrial product photo
Unit of Measure
1/EA
Min Order Qty
1
Micron
0.45 µm
Poly-Fine® II, Filter Cartridges, Removal Rating 0.25 μm, Polypropylene, Length 30 Inches, Fluorocarbon Elastomer, SOE fin end external 226 O-rings product photo
Unit of Measure
1/EA
Min Order Qty
1
Micron
0.25 µm

Description

Why choose Poly-fine XLD pleated depth filter cartridges?

The multi-layer media structure is designed with fine dispersion classification and gel retention in mind.

 

Additional benefits include:

 

  • High flow rates with low-pressure drops
  • Highly consistent, reproducible performance
  • Long service life and low filter cost per gallon

Applications/Use

Applications that most frequently use this product include:

Chemicals and Polymer:

  • Chemicals – Final product (liquid), raw material (gas, air and liquid) and intermediate product
  • Petrochemicals – Amine, Benfield and other solvent loops
  • Polymer – Carbon fiber, nylon and polyurethane production

Microelectronics:

  • Poly-Fine XLD Cartridges for digital ink formulation filtration
  • Multi-layer ceramic capacitors – Wet etch and cleans

Oil and Gas:

  • Upstream – Injection water and SRU
  • Midstream – LNG acid gas, acid gas, glycol filtration and process water
  • Refinery – Amine systems

Specifications

 

Performance Specifications

 

Filter grades

  • 1.5, 3, 4.5, 10, 20, 30, 40, 70, 90 µm

 

Recommended change-out differential pressure1

  • 2.4 bard (35 psid)

 

Maximum differential pressure

  • 4.8 bard (70 psid) @ 20°C (68°F)
  • 2.8 bard (40 psid) @ 65°C (150°F)

 

Food and water contact use

Please contact Pall Corporation to verify that the product conforms to your national legislation and/or regional regulatory requirements for water and food contact use.

 

Cartridge rinse-up

Rinse-up to 18 Megohm-cm with a minimum of throughput.

 

Purity

Cartridges are free of surfactants, resins, binders, and adhesives.

 

Sterilization

Multiple autoclaving for 30 minutes at 121°C (250°F) under no end load conditions. In -line steam sterilization is not recommended. May be in-line sanitized with hot water at 82°C (180°F) for 1 hour.

 

1 Provided that the maximum differential pressure is not exceeded based on temperature limits defined above.

Documents

Data Sheets

  • Poly-Fine XLD Series Filter Cartridges (PIPOLYXLDEN)

    Select Language :
  • POLY-FINE® XLD Filter Cartridges for Digital Ink Formulation

    Select Language :