PREcart PP II Pleated Depth Filter Cartridges

High-Performance Pleated Depth Filters for Particle Removal in Food and Beverage Applications

The PREcart PP II conventional, fan pleated depth filter cartridge is ideal for applications requiring excellent particle removal while effectively prolonging the life of downstream final filters. The highly stable media structure also offers consistent and excellent filtrate quality.

Order Products

Brand

Nexis®

Industries

Industrial Manufacturing

Nexis® T Filter Cartridges, Removal Rating 40 μm, Polypropylene, Length 40 inches, Nitrile, SOE flat closed end external 222 O-rings

Product ID: NXT4040UM3N
Unit of Measure
12/EA
Min Order Qty
12
Removal Rating
40 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
40 in
Cartridge Length (Metric)
1016 mm
Cartridge Length (Metric)
101.6 cm
Gasket / O-Ring Material
Nitrile
See All Attributes

Nexis® T Filter Cartridges, Removal Rating 50 μm, Polypropylene, Length 10 inches, EPDM, SOE flat closed end external 222 O-ring

Product ID: NXT5010UM18E
Unit of Measure
60/EA
Min Order Qty
60
Removal Rating
50 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
10 in
Cartridge Length (Metric)
254 mm
Cartridge Length (Metric)
25.4 cm
Gasket / O-Ring Material
EPDM
See All Attributes

Nexis® T Filter Cartridges, Removal Rating 150 μm, Polypropylene, Length 9.75 inches

Product ID: NXT150975U
Unit of Measure
30/EA
Min Order Qty
30
Removal Rating
150 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
9.75 in
Cartridge Length (Metric)
248 mm
Cartridge Length (Metric)
24.8 cm
Gasket / O-Ring Material
NA
See All Attributes

Nexis® A Series Filter Cartridges, Removal Rating 10 μm, Polypropylene, Length 20 inches, silicone, DOE with elastomer gasket seals and end caps

Product ID: NXA1020UDOES
Unit of Measure
24/EA
Min Order Qty
24
Removal Rating
10 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
20 in
Cartridge Length (Metric)
508 mm
Cartridge Length (Metric)
50.8 cm
Gasket / O-Ring Material
Silicone
See All Attributes

Nexis® A Series Filter Cartridges, Removal Rating 5 μm, Polypropylene, Length 30 inches, silicone, SOE fin end external 226 O-rings

Product ID: NXA530UM7S
Unit of Measure
12/EA
Min Order Qty
12
Removal Rating
5 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
30 in
Cartridge Length (Metric)
762 mm
Cartridge Length (Metric)
76.2 cm
Gasket / O-Ring Material
Silicone
See All Attributes

Nexis® T Filter Cartridges, Removal Rating 5 μm, Polypropylene, Length 4 inches, DOE Santoprene gasket seal

Product ID: NXT54UH21
Unit of Measure
60/EA
Min Order Qty
60
Removal Rating
5 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
4 in
Cartridge Length (Metric)
102 mm
Cartridge Length (Metric)
10.2 cm
Gasket / O-Ring Material
NA
See All Attributes

Nexis® T Filter Cartridges, Removal Rating 20 μm, Polypropylene, Length 20 inches, silicone, DOE with elastomer gasket seals and end caps

Product ID: NXT2020UDOES
Unit of Measure
12/EA
Min Order Qty
12
Removal Rating
20 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
20 in
Cartridge Length (Metric)
508 mm
Cartridge Length (Metric)
50.8 cm
Gasket / O-Ring Material
Silicone
See All Attributes

Nexis® A Series Filter Cartridges, Removal Rating 5 μm, Polypropylene, Length 10 inches, Fluorocarbon Elastomer

Product ID: NXA510UM7V
Unit of Measure
60/EA
Min Order Qty
60
Removal Rating
5 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
10 in
Cartridge Length (Metric)
254 mm
Cartridge Length (Metric)
25.4 cm
Gasket / O-Ring Material
Fluorocarbon Elastomer
See All Attributes

Nexis® A Series Filter Cartridges, Removal Rating 1 μm, Polypropylene, Length 40 inches, silicone, SOE fin end external 226 O-rings

Product ID: NXA140UM7S
Unit of Measure
12/EA
Min Order Qty
12
Removal Rating
1 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
40 in
Cartridge Length (Metric)
1016 mm
Cartridge Length (Metric)
101.6 cm
Gasket / O-Ring Material
Silicone
See All Attributes

MPNT 50-10N

Product ID: MPNT5010N
Unit of Measure
30/EA
Min Order Qty
30

Nexis® T Filter Cartridges, Removal Rating 1 μm, Polypropylene, Length 40 inches, EPDM, SOE fin end external 226 O-rings

Product ID: NXT140UM7E
Unit of Measure
24/EA
Min Order Qty
24
Removal Rating
1 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
40 in
Cartridge Length (Metric)
1016 mm
Cartridge Length (Metric)
101.6 cm
Gasket / O-Ring Material
EPDM
See All Attributes

Nexis® T Filter Cartridges, Removal Rating 1 μm, Polypropylene, Length 10 inches, Fluorocarbon Elastomer, SOE flat closed end external 222 O-rings

Product ID: NXT110UM3V
Unit of Measure
30/EA
Min Order Qty
30
Removal Rating
1 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
10 in
Cartridge Length (Metric)
254 mm
Cartridge Length (Metric)
25.4 cm
Gasket / O-Ring Material
Fluorocarbon Elastomer
See All Attributes

Description

Why choose PREcart PP II pleated depth filter cartridges?

These cartridges are designed to meet typical food and beverage production cycles' high mechanical resistance and compatibility requirements including filtration, sanitization, regeneration, and steam sterilization.

 

Additional benefits include:

 

  • Superior backflush capability for cartridge regeneration
  • Resistance to multiple in situ steam sterilization and hot water sanitization cycles
  • Broad chemical compatibility
  • Food contact compliance and safety

Applications/Use

Food & Beverage:

  • Beer - Prefiltration
  • Distilled Spirits – Activated carbon removal and guard filtration
  • Water and Alcohol-free beverages – Particle removal
  • Wine – First step or single-step prefiltration

Specifications

 

Quality

  • Cartridges produced in a controlled environment
  • Manufactured within a Quality Manufacturing System certified to ISO 9001:2015

 

Food Contact Compliance

Please refer to the Pall website for a Declaration of Compliance to specific National Legislation and/or Regional Regulatory requirements for food contact use.

 

Technical Information

The technical information provided is based on controlled laboratory tests done on typical production filters at the conditions described unless otherwise indicated. Actual operating conditions may affect the filter's performance.

 

PERFORMANCE

 

Operating Characteristics in Compatible Fluids1

Maximum Differential Pressure Operating Temperature
   5.0 bard (72.5 psid) (forward) 25 °C (77 °F)
 2.0 bard (29 psid) (forward)   80 °C (176 °F)
   1.5 bard (21.8 psid) (forward)    90 °C (194 °F)
1 bard (14.5 psid) (reverse)    60 °C (140 °F)

 

1Fluids which do not swell, soften, or adversely affect any of the filter components.

 

Table 1: Removal Rating2

Code Description
110 1 µm
120 2 µm
130 3 µm
150 5 µm
210 10 µm
220 20 µm

 

2PREcart PP filter cartridge liquid retention ratings are based on a modified OSU-F2 single pass test. The removal efficiency for all grades is 99.98%.

Documents

Data Sheets

  • PREcart PP II Filter Cartridges for Particle Removal

    Select Language :