PREcart PP II Pleated Depth Filter Cartridges

High-Performance Pleated Depth Filters for Particle Removal in Food and Beverage Applications

The PREcart PP II conventional, fan pleated depth filter cartridge is ideal for applications requiring excellent particle removal while effectively prolonging the life of downstream final filters. The highly stable media structure also offers consistent and excellent filtrate quality.

Order Products

Brand

Nexis®

Availability

In Stock

NXA 2-20U-M3E product photo

Nexis, NXA, 2 μm, 50.8 cm (20 in), SOE flat closed end, external 222 O-rings (retrofits other manufacturers’ Code 0), EPDM gasket

Product ID: NXA220UM3E
Unit of Measure
1/EA
Min Order Qty
1
Micron
2 micron

Nexis® T Filter Cartridges, Removal Rating 25 μm, Polypropylene, Length 20 inches

Product ID: NXT2520U
Unit of Measure
20/EA
Min Order Qty
20
Removal Rating
25 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
20 in
Cartridge Length (Metric)
508 mm
Cartridge Length (Metric)
50.8 cm
Gasket / O-Ring Material
NA
See All Attributes

Nexis® T Filter Cartridges, Removal Rating 120 μm, Polypropylene, Length 30 inches

Product ID: NXT12030U
Unit of Measure
10/EA
Min Order Qty
10
Removal Rating
120 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
30 in
Cartridge Length (Metric)
762 mm
Cartridge Length (Metric)
76.2 cm
Gasket / O-Ring Material
NA
See All Attributes

Nexis® T Filter Cartridges, Removal Rating 1 μm, Polypropylene, Length 30 inches

Product ID: NXT130U916
Unit of Measure
240/EA
Min Order Qty
240
Removal Rating
1 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
30 in
Cartridge Length (Metric)
762 mm
Cartridge Length (Metric)
76.2 cm
Gasket / O-Ring Material
NA
See All Attributes
Nexis® A Series Filter Cartridges, Removal Rating 1 μm, Polypropylene, Length 30 inches, DOE Santoprene gasket seal product photo

Nexis® A Series Filter Cartridges, Removal Rating 1 μm, Polypropylene, Length 30 inches, DOE Santoprene gasket seal

Product ID: NXA130UH21
Unit of Measure
1/EA
Min Order Qty
1
Micron
1 micron
Nexis® A Series Filter Cartridges, Removal Rating 40 μm, Polypropylene, Length 20 inches product photo

Nexis® A Series Filter Cartridges, Removal Rating 40 μm, Polypropylene, Length 20 inches

Product ID: NXA4020U
Unit of Measure
1/pkg
Min Order Qty
1
Micron
40 micron

Nexis® T Filter Cartridges, Removal Rating 10 μm, Polypropylene, Length 40 inches, silicone, SOE fin end external 226 O-rings

Product ID: NXT1040UM7S
Unit of Measure
24/EA
Min Order Qty
24
Removal Rating
10 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
40 in
Cartridge Length (Metric)
1016 mm
Cartridge Length (Metric)
101.6 cm
Gasket / O-Ring Material
Silicone
See All Attributes

A-9935 249

Product ID: A9935249
Unit of Measure
10/EA
Min Order Qty
10
Nexis® A Series Filter Cartridges, Removal Rating 1 μm, Polypropylene, Length 30 inches, silicone, SOE flat closed end external 222 O-rings product photo
Unit of Measure
1/EA
Min Order Qty
1
Micron
1 micron

Description

Why choose PREcart PP II pleated depth filter cartridges?

These cartridges are designed to meet typical food and beverage production cycles' high mechanical resistance and compatibility requirements including filtration, sanitization, regeneration, and steam sterilization.

 

Additional benefits include:

 

  • Superior backflush capability for cartridge regeneration
  • Resistance to multiple in situ steam sterilization and hot water sanitization cycles
  • Broad chemical compatibility
  • Food contact compliance and safety

Applications/Use

Food & Beverage:

  • Beer - Prefiltration
  • Distilled Spirits – Activated carbon removal and guard filtration
  • Water and Alcohol-free beverages – Particle removal
  • Wine – First step or single-step prefiltration

Specifications

 

Quality

  • Cartridges produced in a controlled environment
  • Manufactured within a Quality Manufacturing System certified to ISO 9001:2015

 

Food Contact Compliance

Please refer to the Pall website for a Declaration of Compliance to specific National Legislation and/or Regional Regulatory requirements for food contact use.

 

Technical Information

The technical information provided is based on controlled laboratory tests done on typical production filters at the conditions described unless otherwise indicated. Actual operating conditions may affect the filter's performance.

 

PERFORMANCE

 

Operating Characteristics in Compatible Fluids1

Maximum Differential Pressure Operating Temperature
   5.0 bard (72.5 psid) (forward) 25 °C (77 °F)
 2.0 bard (29 psid) (forward)   80 °C (176 °F)
   1.5 bard (21.8 psid) (forward)    90 °C (194 °F)
1 bard (14.5 psid) (reverse)    60 °C (140 °F)

 

1Fluids which do not swell, soften, or adversely affect any of the filter components.

 

Table 1: Removal Rating2

Code Description
110 1 µm
120 2 µm
130 3 µm
150 5 µm
210 10 µm
220 20 µm

 

2PREcart PP filter cartridge liquid retention ratings are based on a modified OSU-F2 single pass test. The removal efficiency for all grades is 99.98%.

Documents

Data Sheets

  • PREcart PP II Filter Cartridges for Particle Removal

    Select Language :