PREcart PP II Pleated Depth Filter Cartridges

High-Performance Pleated Depth Filters for Particle Removal in Food and Beverage Applications

The PREcart PP II conventional, fan pleated depth filter cartridge is ideal for applications requiring excellent particle removal while effectively prolonging the life of downstream final filters. The highly stable media structure also offers consistent and excellent filtrate quality.

Order Products

Diameter

287 mm

SUPRAdisc SD II EK 200XEK0C232SPW

Product ID: 7007869
Unit of Measure
1/EA
Min Order Qty
1
1. Recommended Max. Backpressure During Backwash
0.5 bar
2. Recommended Max. Backpressure During Backwash
7.25 psid
Adaptor Type
Double Open End, Flat Gasket
Core Drainage Discs
Polypropylene
Diameter (Imperial)
12 in
Diameter (Metric)
287 mm
See All Attributes

SUPRAdisc SD II 150 200X150C232SPW

Product ID: 7007867
Unit of Measure
1/EA
Min Order Qty
1
1. Recommended Max. Backpressure During Backwash
0.5 bar
2. Recommended Max. Backpressure During Backwash
7.25 psid
Adaptor Type
Double Open End, Flat Gasket
Core Drainage Discs
Polypropylene
Diameter (Imperial)
12 in
Diameter (Metric)
287 mm
See All Attributes

SUPRAdisc SD II EK 1 200XEK1C232SPW

Product ID: 7007871
Unit of Measure
1/EA
Min Order Qty
1
1. Recommended Max. Backpressure During Backwash
0.5 bar
2. Recommended Max. Backpressure During Backwash
7.25 psid
Adaptor Type
Double Open End, Flat Gasket
Core Drainage Discs
Polypropylene
Diameter (Imperial)
12 in
Diameter (Metric)
287 mm
See All Attributes

SUPRAdisc SD II 080 200X080C232SPW

Product ID: 7007865
Unit of Measure
1/EA
Min Order Qty
1
1. Recommended Max. Backpressure During Backwash
0.5 bar
2. Recommended Max. Backpressure During Backwash
7.25 psid
Adaptor Type
Double Open End, Flat Gasket
Core Drainage Discs
Polypropylene
Diameter (Imperial)
12 in
Diameter (Metric)
287 mm
See All Attributes

SUPRAdisc SD II 200 200X200C232SPW

Product ID: 7007870
Unit of Measure
1/EA
Min Order Qty
1
1. Recommended Max. Backpressure During Backwash
0.5 bar
2. Recommended Max. Backpressure During Backwash
7.25 psid
Adaptor Type
Double Open End, Flat Gasket
Core Drainage Discs
Polypropylene
Diameter (Imperial)
12 in
Diameter (Metric)
287 mm
See All Attributes

SUPRAdisc SD II 250 200X250C232SPW

Product ID: 7007868
Unit of Measure
1/EA
Min Order Qty
1
1. Recommended Max. Backpressure During Backwash
0.5 bar
2. Recommended Max. Backpressure During Backwash
7.25 psid
Adaptor Type
Double Open End, Flat Gasket
Core Drainage Discs
Polypropylene
Diameter (Imperial)
12 in
Diameter (Metric)
287 mm
See All Attributes

SUPRAdisc SD II 900 200X900C232SPW

Product ID: 7007882
Unit of Measure
1/EA
Min Order Qty
1
1. Recommended Max. Backpressure During Backwash
0.5 bar
2. Recommended Max. Backpressure During Backwash
7.25 psid
Adaptor Type
Double Open End, Flat Gasket
Core Drainage Discs
Polypropylene
Diameter (Imperial)
12 in
Diameter (Metric)
287 mm
See All Attributes

SUPRAdisc SD II 700 200X700C232SPW

Product ID: 7007866
Unit of Measure
1/EA
Min Order Qty
1
1. Recommended Max. Backpressure During Backwash
0.5 bar
2. Recommended Max. Backpressure During Backwash
7.25 psid
Adaptor Type
Double Open End, Flat Gasket
Core Drainage Discs
Polypropylene
Diameter (Imperial)
12 in
Diameter (Metric)
287 mm
See All Attributes

SUPRAdisc SD II 100 200X100C232SPW

Product ID: 7007872
Unit of Measure
1/EA
Min Order Qty
1
1. Recommended Max. Backpressure During Backwash
0.5 bar
2. Recommended Max. Backpressure During Backwash
7.25 psid
Adaptor Type
Double Open End, Flat Gasket
Core Drainage Discs
Polypropylene
Diameter (Imperial)
12 in
Diameter (Metric)
287 mm
See All Attributes

SUPRAdisc SD II 300 200X300C232SPW

Product ID: 7007876
Unit of Measure
1/EA
Min Order Qty
1
1. Recommended Max. Backpressure During Backwash
0.5 bar
2. Recommended Max. Backpressure During Backwash
7.25 psid
Adaptor Type
Double Open End, Flat Gasket
Core Drainage Discs
Polypropylene
Diameter (Imperial)
12 in
Diameter (Metric)
287 mm
See All Attributes

Description

Why choose PREcart PP II pleated depth filter cartridges?

These cartridges are designed to meet typical food and beverage production cycles' high mechanical resistance and compatibility requirements including filtration, sanitization, regeneration, and steam sterilization.

 

Additional benefits include:

 

  • Superior backflush capability for cartridge regeneration
  • Resistance to multiple in situ steam sterilization and hot water sanitization cycles
  • Broad chemical compatibility
  • Food contact compliance and safety

Applications/Use

Food & Beverage:

  • Beer - Prefiltration
  • Distilled Spirits – Activated carbon removal and guard filtration
  • Water and Alcohol-free beverages – Particle removal
  • Wine – First step or single-step prefiltration

Specifications

 

Quality

  • Cartridges produced in a controlled environment
  • Manufactured within a Quality Manufacturing System certified to ISO 9001:2015

 

Food Contact Compliance

Please refer to the Pall website for a Declaration of Compliance to specific National Legislation and/or Regional Regulatory requirements for food contact use.

 

Technical Information

The technical information provided is based on controlled laboratory tests done on typical production filters at the conditions described unless otherwise indicated. Actual operating conditions may affect the filter's performance.

 

PERFORMANCE

 

Operating Characteristics in Compatible Fluids1

Maximum Differential Pressure Operating Temperature
   5.0 bard (72.5 psid) (forward) 25 °C (77 °F)
 2.0 bard (29 psid) (forward)   80 °C (176 °F)
   1.5 bard (21.8 psid) (forward)    90 °C (194 °F)
1 bard (14.5 psid) (reverse)    60 °C (140 °F)

 

1Fluids which do not swell, soften, or adversely affect any of the filter components.

 

Table 1: Removal Rating2

Code Description
110 1 µm
120 2 µm
130 3 µm
150 5 µm
210 10 µm
220 20 µm

 

2PREcart PP filter cartridge liquid retention ratings are based on a modified OSU-F2 single pass test. The removal efficiency for all grades is 99.98%.