PREcart PP II Pleated Depth Filter Cartridges

High-Performance Pleated Depth Filters for Particle Removal in Food and Beverage Applications

The PREcart PP II conventional, fan pleated depth filter cartridge is ideal for applications requiring excellent particle removal while effectively prolonging the life of downstream final filters. The highly stable media structure also offers consistent and excellent filtrate quality.

Order Products

Industries

Food & Beverage

Product Type

Filter Cartridges

Filter Media

Polypropylene

Poly-Fine® II Filter Cartridge, PFT520USM7W480 product photo

Poly-Fine® II Filter Cartridge, PFT520USM7W480

Product ID: PFT520USM7W480
Unit of Measure
1/EA
Min Order Qty
1
Micron
5 µm

Profile® UP Filter Cartridges, 30 in, 10 µm, Silicone Elastomer

Product ID: AB3UY1007WH4
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
10 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
30 in
Cartridge Length (Metric)
762 mm
Cartridge Length (Metric)
76.2 cm
Gasket / O-Ring Material
Silicone Elastomer
See All Attributes

Profile® II Filter Cartridges, R1F010W

Product ID: R1F010W
Unit of Measure
6/EA
Min Order Qty
6
Removal Rating
1 µm
Membrane Material
Polypropylene
Industry-Specific Certification
W480 Food Contact
Filter Cartridge Style
RF-style
Cartridge Length (Imperial)
10 in
Cartridge Length (Metric)
254 mm
See All Attributes
Poly-Fine® II Filter Cartridge, PFT04510USM3W480 product photo

Poly-Fine® II Filter Cartridge, PFT04510USM3W480

Product ID: PFT04510USM3W480
Unit of Measure
1/EA
Min Order Qty
1
Micron
0.45 µm

Nexis® T Series Filter Cartridges, Polypropylene, 30 µm, 30 in., Silicone Elastomer, M7

Product ID: NXT3030UM7WS480
Unit of Measure
12/EA
Min Order Qty
12
Removal Rating
30 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
30 in
Cartridge Length (Metric)
762 mm
Cartridge Length (Metric)
76.2 cm
Gasket / O-Ring Material
Silicone Elastomer
See All Attributes
Poly-Fine® II Filter Cartridge, PFT510UEW480 product photo

Poly-Fine® II Filter Cartridge, PFT510UEW480

Product ID: PFT510UEW480
Unit of Measure
1/EA
Min Order Qty
1
Micron
5 µm

Claris® Filter Cartridge, CLR110W480

Product ID: CLR110W480
Unit of Measure
36/EA
Min Order Qty
36
Removal Rating
1 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
10 in
Cartridge Length (Metric)
254 mm
Cartridge Length (Metric)
25.4 cm
Gasket O-Ring Code
Blank
See All Attributes

Claris® Filter Cartridge, 1 µm, 30 in, Single Open Ended with Fin End and External 222 O-rings

Product ID: CLR130M8WS480
Unit of Measure
12/EA
Min Order Qty
12
Removal Rating
1 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
30 in
Cartridge Length (Metric)
762 mm
Cartridge Length (Metric)
76.2 cm
Gasket / O-Ring Material
Silicone Elastomer
See All Attributes

Claris® Filter Cartridge, 3 µm, 10 in, Double Open Ended with No Endcaps

Product ID: CLR310W480
Unit of Measure
36/EA
Min Order Qty
36
Removal Rating
3 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
10 in
Cartridge Length (Metric)
254 mm
Cartridge Length (Metric)
25.4 cm
Change Out Differential Pressure
2.4 bard
See All Attributes

Profile® II Filter Cartridge 20 in, 5 µm

Product ID: RM2F005W
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
8 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
20 in
Cartridge Length (Metric)
508 mm
Cartridge Length (Metric)
50.8 cm
Maximum Differential Pressure
4 bard (60 psid)
See All Attributes
Poly-Fine® II Filter Cartridge, PFT02540USM7W480 product photo

Poly-Fine® II Filter Cartridge, PFT02540USM7W480

Product ID: PFT02540USM7W480
Unit of Measure
12/EA
Min Order Qty
12
Micron
0.25 µm

Nexis® T Series Filter Cartridges, Polypropylene, 5 µm, 30 in., No End Caps

Product ID: NXT530UW480
Unit of Measure
10/EA
Min Order Qty
10
Removal Rating
5 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
30 in
Cartridge Length (Metric)
762 mm
Cartridge Length (Metric)
76.2 cm
Change Out Differential Pressure
2.4 bard
See All Attributes

Description

Why choose PREcart PP II pleated depth filter cartridges?

These cartridges are designed to meet typical food and beverage production cycles' high mechanical resistance and compatibility requirements including filtration, sanitization, regeneration, and steam sterilization.

 

Additional benefits include:

 

  • Superior backflush capability for cartridge regeneration
  • Resistance to multiple in situ steam sterilization and hot water sanitization cycles
  • Broad chemical compatibility
  • Food contact compliance and safety

Applications/Use

Food & Beverage:

  • Beer - Prefiltration
  • Distilled Spirits – Activated carbon removal and guard filtration
  • Water and Alcohol-free beverages – Particle removal
  • Wine – First step or single-step prefiltration

Specifications

 

Quality

  • Cartridges produced in a controlled environment
  • Manufactured within a Quality Manufacturing System certified to ISO 9001:2015

 

Food Contact Compliance

Please refer to the Pall website for a Declaration of Compliance to specific National Legislation and/or Regional Regulatory requirements for food contact use.

 

Technical Information

The technical information provided is based on controlled laboratory tests done on typical production filters at the conditions described unless otherwise indicated. Actual operating conditions may affect the filter's performance.

 

PERFORMANCE

 

Operating Characteristics in Compatible Fluids1

Maximum Differential Pressure Operating Temperature
   5.0 bard (72.5 psid) (forward) 25 °C (77 °F)
 2.0 bard (29 psid) (forward)   80 °C (176 °F)
   1.5 bard (21.8 psid) (forward)    90 °C (194 °F)
1 bard (14.5 psid) (reverse)    60 °C (140 °F)

 

1Fluids which do not swell, soften, or adversely affect any of the filter components.

 

Table 1: Removal Rating2

Code Description
110 1 µm
120 2 µm
130 3 µm
150 5 µm
210 10 µm
220 20 µm

 

2PREcart PP filter cartridge liquid retention ratings are based on a modified OSU-F2 single pass test. The removal efficiency for all grades is 99.98%.

Documents

Data Sheets

  • PREcart PP II Filter Cartridges for Particle Removal

    Select Language :