Poly-Fine® II Series Pleated Filter Cartridges

A Cost-Effective Choice for Final Particle Removal and Pre-filtration in Liquids, Air and Gas - Including Reliable Protection of Final Membrane Filters

The Poly-Fine II pleated filter cartridge element is a high area, all-polypropylene depth filter cartridge frequently used in a wide variety of applications. These filter cartridges have broad chemical capability and are constructed of ultra-thin, proprietary melt-blown filter media that is intended for particle removal, excluding oils. 

Order Products

Red1000 Glass Fiber 12 micron (Beta 1000) Nitrile 36in 91.44cm

Product ID: HC2296FKS36H
Unit of Measure
1/EA
Min Order Qty
6
Anti-Static
No
Beta Rating
BETA 1000
Element Series
HC2296
Family
Red1000
Filter Media
Glass Fiber
Filter Removal Rating (μm)
12 µm
See All Attributes

Ultipor III Glass Fiber 5 micron (Beta 1000) Nitrile 8in 20.32cm length

Product ID: HC9601FDP8H#28
Unit of Measure
1/EA
Min Order Qty
1
Anti-Static
No
Beta Rating
BETA 1000
Element Series
HC9601
Family
Ultipor III
Filter Media
Glass Fiber
Filter Removal Rating (μm)
5 µm
See All Attributes
PSC06-10-S-DOE/8082160000 product photo

PSC06-10-S-DOE/8082160000

Product ID: DC1000HDOH06C
Unit of Measure
1/EA
Min Order Qty
1
DFN 3-30AN-1X product photo

DFN 3-30AN-1X

Product ID: DFN330AN1X
Unit of Measure
12/EA
Min Order Qty
12

This product is currently not available. Please contact us for more information.

DFNE50040AV

Product ID: DFNE50040AV
Unit of Measure
12/EA
Min Order Qty
12

Duo-Fine® II, Filter Cartridges, Removal Rating 0.45 μm, Length 20 Inches, silicone, SOE fin end external 226 O-rings

Product ID: DFNT04520USM7
Unit of Measure
12/EA
Min Order Qty
12
Removal Rating
0.45 µm
End Configuration
SOE fin end, external 226 O-rings
Change Out Differential Pressure
2.4 bard

Duo-Fine® II, Filter Cartridges, Removal Rating 1 μm, Length 20 Inches, silicone, SOE fin end external 222 O-rings

Product ID: DFNT120USM8
Unit of Measure
12/EA
Min Order Qty
12
Removal Rating
1 µm
End Configuration
SOE fin end, external 222 O-rings
Change Out Differential Pressure
2.4 bard

DFNT 1-30UN-M7

Product ID: DFNT130UNM7
Unit of Measure
1/EA
Min Order Qty
1

Duo-Fine®, Filter Cartridges, Removal Rating 0.2 μm, Length 40 Inches

Product ID: DFPT0240UGTMG7
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
0.2 µm
Cartridge Length (Imperial)
40 in
Cartridge Length (Metric)
1016 mm
Cartridge Length (Metric)
101.6 cm
Change Out Differential Pressure
2.4 bard
Cartridge Outer Diameter (OD) (Imperial)
2.5 in
See All Attributes
DFPT 1-30EV-M3 product photo

DFPT 1-30EV-M3

Product ID: DFPT130EVM3
Unit of Measure
1/EA
Min Order Qty
1

Description

Why choose Poly-Fine II pleated filter cartridges?

The highly consistent pore structure with narrow pore size distribution and removal ratings ranging from 0.2 to 100 µm makes these filter cartridges ideal for capturing non-deformable contaminants, particularly those characterized by limited particle distribution.

 

Additional benefits include:

 

  • All polypropylene one-piece construction (except 0.2 µm)
  • Constructed from proprietary melt blown, pleated media
  • High dirt holding capacity
  • Long service life

Applications

Industry Application Examples of Use
Chemical and Polymers

Final product

Amine, Benfield and other solid loops

Carbon fiber production 

  • Liquids
  • Petrochemicals
  • Polymers
Food and Beverage

Prefiltration

Air, gas and vent filtration

  • Mineral flavor and filtration in bottled water
  • Cannabis
Oil and Gas 

Upstream

Midstream

  • Injection water and SRU
  • LNG acid gas, midstream acid gas, glycol filtration, process water

Specifications

 

Food Contact Compliance

Please refer to the Pall website for a Declaration of Compliance to specific National Legislation and/or Regional Regulatory requirements for food contact use.

 

Quality

 

  • Cartridges produced in a controlled environment
  • Manufactured within a Quality Management System certified to ISO 9001:2015.

 

Technical Information

The technical information provided is based on controlled laboratory tests done on typical production filters at the conditions described unless otherwise indicated. Actual operating conditions may affect the filter's performance.

 

Particle Retention (µm) for Chemical and Polymer, and Oil and Gas Applications

 

  Liquid Service
(by ASTM F-795 Test)
Gas Service
Cartridge
Designation
90%
Efficiency
>99.9%
Efficiency
Removal Efficiency
By DOP Test
PFT 0.2 0.2 0.5 99.99%
PFT 0.25 0.25 1.0 99.97%
PFT 0.45 0.45 1.2 99.93%
PFT 0.8 0.8 2.5 99.90%
PFT 2.0 2 5 -
PFT 3.0 3 7 -
PFT 5.0 5 12 -
PFT 10.0 10 15 -
PFT 30.0 30 40 -
PFT 50.0 50 65 -
PFT 100.0 85 100 -

 

Table 1: Removal Rating1 for Food and Beverage Applications

 

                                                                                 Description
Code 90% Efficiency (Beta 10) >99.9% Efficiency (Beta 1000)
0.25 0.25 µm 1 µm
045 0.45 µm 1.2 µm
08 0.8 µm 2.5 µm
2 2 µm 5 µm
3 3 µm 7 µm
5 5 µm 12 µm
10 10 µm 15 µm
30 30 µm 40 µm

 

1Poly-Fine II filter cartridge liquid retention ratings are determined by a single pass test based on ASTM F-795 (see Pall Technical Bulletin 1903-4T). Removal efficiencies are shown at the stated rating in compatible fluids.

 

Operating Characteristics2

 

Maximum Differential Pressure3 Operating Temperature
4.8 bard (70 psid) (forward) 20 °C (68 °F)
2.8 bard (40 psid) (forward) 65 °C (150 °F)

 

2Fluids which do not swell, soften, or adversely affect any of the filter components.

3Recommended change-out differential pressure is 2.4 bard (35 psid), provided the maximum differential pressure (based on temperature) is not exceeded.

 

PERFORMANCE

 

Typical Flow Rates4 for Chemical and Polymer, and Oil and Gas Applications

 

Typical Flow vs. Differential Pressure for Application Sizing

Flow rate is for a 25.4 cm (10 in) cartridge. For liquids other than water, multiply differential pressure by fluid viscosity (cP).

 

 

Typical Flow Rates for Food and Beverage Applications

4Typical initial clean delta p per 254 mm (10 inch) cartridge, water at 20° C (68° F). For liquids with viscosity greater than 1cP, multiply the delta p by the viscosity.

Documents

Data Sheets

  • FBPFTIILEN - Poly-Fine® II Filter Cartridges Particle Filtration For Liquids

    Select Language :
  • Poly-Fine II Series Filter Cartridges (PIPOLYIIEN)

    Select Language :