Encore® String Wound Filter Cartridges

Multi-Purpose Filter Cartridges for Applications Involving Boiler Water Systems

Encore string wound filter cartridges are for the cost-efficient, high-efficiency filtration of fluids. They are available in premium cotton, standard cotton, premium polypropylene, natural cotton, or general-purpose polypropylene filter media and come in retention ratings from 1 – 200 µm.

Order Products

Industries

Industrial Manufacturing

Seal Material

Fluorocarbon

Athalon Glass Fiber 7 micron (Beta 2000) Fluorocarbon 4in 10.16cm

Product ID: UE299AN04Z
Unit of Measure
6/EA
Min Order Qty
6
Anti-Static
Yes
Beta Rating
BETA 2000
Element Series
UE299
Family
Athalon
Filter Media
Glass Fiber
Filter Removal Rating (μm)
7 µm
See All Attributes

Supralon™ Lube and Hydraulic Fluid Filter Elements, Removal Rating 7 μm, GlassFiber, Length 30 Inches

Product ID: HC2285FRN30Z
Unit of Measure
12/EA
Min Order Qty
12
Anti-Static
Yes
Beta Rating
BETA 2000
Element Series
HC2285
Family
Supralon
Filter Media
Glass Fiber
Filter Removal Rating
7 micron (Beta 2000)
See All Attributes

Supralon™ Lube and Hydraulic Fluid Filter Elements, Removal Rating 7 μm, GlassFiber, Length 15 Inches

Product ID: HC2286FRN15Z50
Unit of Measure
6/EA
Min Order Qty
6
Anti-Static
Yes
Beta Rating
BETA 2000
Element Series
HC2286
Family
Supralon
Filter Media
Glass Fiber
Filter Removal Rating
7 micron (Beta 2000)
See All Attributes

Supralon™ Lube and Hydraulic Fluid Filter Elements, Removal Rating 3 μm, GlassFiber, Length 9 inches

Product ID: HC9700FRZ9Z
Unit of Measure
1/EA
Min Order Qty
1
Anti-Static
Yes
Beta Rating
BETA 2000
Element Series
HC9700
Family
Supralon
Filter Media
Glass Fiber
Filter Removal Rating
3 micron (Beta 2000)
See All Attributes

Supralon™ Lube and Hydraulic Fluid Filter Elements, Removal Rating 5 μm, GlassFiber, Length 8 inches

Product ID: HC9800FRP8ZYMC
Unit of Measure
6/EA
Min Order Qty
6
Anti-Static
Yes
Beta Rating
BETA 2000
Element Series
HC9800
Family
Supralon
Filter Media
Glass Fiber
Filter Removal Rating
5 micron (Beta 2000)
See All Attributes

Supralon™ Lube and Hydraulic Fluid Filter Elements, Removal Rating 12 μm, GlassFiber, Length 13 inches

Product ID: HC9101FHS13Z
Unit of Measure
6/EA
Min Order Qty
6
Anti-Static
Yes
Beta Rating
BETA 2000
Element Series
HC9101
Family
Supralon
Filter Media
Glass Fiber
Filter Removal Rating
12 micron (Beta 2000)
See All Attributes

Supralon™ Lube and Hydraulic Fluid Filter Elements, Removal Rating 5 μm, GlassFiber, Length 4 inches

Product ID: HC9801FHP4ZYMC
Unit of Measure
1/EA
Min Order Qty
1
Anti-Static
Yes
Beta Rating
BETA 2000
Element Series
HC9801
Family
Supralon
Filter Media
Glass Fiber
Filter Removal Rating
5 micron (Beta 2000)
See All Attributes

Supralon™ Lube and Hydraulic Fluid Filter Elements, Removal Rating 12 μm, GlassFiber, Length 9 inches

Product ID: HC9701FHS9Z
Unit of Measure
1/EA
Min Order Qty
1
Anti-Static
Yes
Beta Rating
BETA 2000
Element Series
HC9701
Family
Supralon
Filter Media
Glass Fiber
Filter Removal Rating
12 micron (Beta 2000)
See All Attributes

Ultipor Glass Fiber 5µm Fluorocarbon Seal 18in 45.72cm length

Product ID: HC2295FKP18Z
Unit of Measure
1/EA
Min Order Qty
1
Anti-Static
No
Beta Rating
BETA 1000
Element Series
HC2295
Family
Ultipor
Filter Media
Glass Fiber
Filter Removal Rating (μm)
5 µm
See All Attributes

ELEMENT UE610AZ40Z

Product ID: UE610AZ40Z
Unit of Measure
1/EA
Min Order Qty
1
Anti-Static
Yes
Beta Rating
BETA 2000
Element Series
UE610
Family
Athalon
Filter Media
Glass Fiber
Filter Removal Rating
3 micron (Beta 2000)
See All Attributes

Supralon™ Lube and Hydraulic Fluid Filter Elements, Removal Rating 5 μm, GlassFiber, Length 13 inches

Product ID: HC9804FRP13Z
Unit of Measure
3/EA
Min Order Qty
3
Anti-Static
Yes
Beta Rating
BETA 2000
Element Series
HC9804
Family
Supralon
Filter Media
Glass Fiber
Filter Removal Rating
5 micron (Beta 2000)
See All Attributes

Supralon™ Lube and Hydraulic Fluid Filter Elements, Removal Rating 7 μm, GlassFiber, Length 26 inches

Product ID: HC4754FRN26Z
Unit of Measure
6/EA
Min Order Qty
6
Anti-Static
Yes
Beta Rating
BETA 2000
Element Series
HC4754
Family
Supralon
Filter Media
Glass Fiber
Filter Removal Rating
7 micron (Beta 2000)
See All Attributes

Applications/Use

Oil and Gas:

  • Upstream - Injection water & SRU, offshore boiler water, offshore produced water and onshore surface discharged water
  • Midstream – Process water

Specifications

 

Filter Grades: 1, 3, 5, 10, 20, 25, 30, 40, 50, 75, 100, 200 µm

 

Materials of Construction

 

Filter Media: Bleached FDA-listed cotton, standard cotton, natural cotton, FDA-listed polypropylene, standard polypropylene

 

Material Selection Guide

Filter Medium Premium Cotton1 Standard Cotton Natural Cotton Premium Polypropylene1 Standard Polypropylene

 

Maximum Temperature

Electrolytic Tin Plated Steel Core 300°F (149°C) 300°F (149°C) 300°F (149°C) 275°F (135°C) 275°F (135°C)
Stainless Steel Core 300°F (149°C) 300°F (149°C) 300°F (149°C) 275°F (135°C) 275°F (135°C)
Polypropylene Core 140°F (60°C) 140°F (60°C) 140°F (60°C) 140°F (60°C) 140°F (60°C)

 

Compatibility with:

Food Excellent NR NR Excellent NR
Beverages Excellent NR NR Excellent NR
Potable Water Excellent NR NR Excellent NR
Organic Solvents Excellent Excellent Excellent Good Good
Oils Excellent Excellent Excellent Fair Excellent
Organic Acids Good Good Good Excellent Excellent
Alkalis Good Good Good Excellent Excellent
Oxidizing Agents Fair Fair Fair Good Good
Steam NR NR NR Fair NR
Strong Inorganic Acids NR NR NR Excellent Excellent
Dilute Inorganic Acids Fair Fair Fair Excellent Excellent
Micro-organism Resistance Poor Poor Poor Excellent Excellent

 

1 - FDA-listed materials. NR = Not Recommended