Encore® String Wound Filter Cartridges

Multi-Purpose Filter Cartridges for Applications Involving Boiler Water Systems

Encore string wound filter cartridges are for the cost-efficient, high-efficiency filtration of fluids. They are available in premium cotton, standard cotton, premium polypropylene, natural cotton, or general-purpose polypropylene filter media and come in retention ratings from 1 – 200 µm.

Order Products

Outlet Connection

½ in (13 mm) hose barb

Supor® EKV membrane in Kleenpak™ capsule, 0.2 µm removal rating, 375 cm² EFA, ½ in. hose barb connections, suitable for gamma irradiation product photo

Supor® EKV membrane in Kleenpak™ capsule, 0.2 µm removal rating, 375 cm² EFA, ½ in. hose barb connections, suitable for gamma irradiation

Product ID: KA1EKVP6G
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
0.2 µm
Membrane Material
Polyethersulfone (PES)
Effective Filtration Area
375 cm²
Sterilization Option(s)
Suitable for Gamma Irradiation, Suitable for Autoclave
Inlet Connection
½ in (13 mm) hose barb
See All Attributes
Supor® EKV membrane in Kleenpak™ capsule, 0.2 µm removal rating, 375 cm² EFA, ½ in. hose barb connections, pre-sterilized by gamma irradiation product photo

Supor® EKV membrane in Kleenpak™ capsule, 0.2 µm removal rating, 375 cm² EFA, ½ in. hose barb connections, pre-sterilized by gamma irradiation

Product ID: KA1EKVP6S
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
0.2 µm
Membrane Material
Polyethersulfone (PES)
Effective Filtration Area
375 cm²
Sterilization Option(s)
Provided Pre-Sterilized by Gamma Irradiation
Inlet Connection
½ in (13 mm) hose barb
See All Attributes

This product is currently not available. Please contact us for more information.

Fluorodyne® II DFL membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 800 cm² EFA, 1½ in. sanitary flange inlet and ½ in. hose barb outlet connections, pre-sterilized by gamma irradiation product photo

Fluorodyne® II DFL membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 800 cm² EFA, 1½ in. sanitary flange inlet and ½ in. hose barb outlet connections, pre-sterilized by gamma irradiation

Product ID: KA2DFLP16S
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
0.2 µm
Membrane Material
Polyvinylidene fluoride (PVDF)
Sterilization Option(s)
Provided Pre-Sterilized by Gamma Irradiation
See All Attributes

This product is currently not available. Please contact us for more information.

Supor® EKV membrane in Kleenpak™ capsule, 0.2 µm removal rating, 750 cm² EFA, ½ in. hose barb connections, pre-sterilized by gamma irradiation product photo

Supor® EKV membrane in Kleenpak™ capsule, 0.2 µm removal rating, 750 cm² EFA, ½ in. hose barb connections, pre-sterilized by gamma irradiation

Product ID: KA2EKVP6S
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
0.2 µm
Membrane Material
Polyethersulfone (PES)
Effective Filtration Area
750 cm²
Sterilization Option(s)
Provided Pre-Sterilized by Gamma Irradiation
Inlet Connection
½ in (13 mm) hose barb
See All Attributes

This product is currently not available. Please contact us for more information.

Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 1700 cm² EFA, ½ in. hose barb connections, suitable for gamma irradiation product photo

Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 1700 cm² EFA, ½ in. hose barb connections, suitable for gamma irradiation

Product ID: KA3V002PV6G
Unit of Measure
1/EA
Min Order Qty
1
Membrane Material
Polyvinylidene fluoride (PVDF)
Effective Filtration Area (Metric)
1700 cm²
See All Attributes

Emflon® II Membrane in Kleenpak™ Capsules serves the user's specific systematic needs. Pall offers options including gama-irradiatable, pre-sterilized and custom-made sets. All versions perform to the same top quality standard. Each unit is fully integrity testable and has the highly retentive Emflon II membrane. These capsule filters provide high air flows of both air and gas.

9 Products In Family

Fluorodyne® II DFL Membrane in Kleenpak™ Capsules provides many benefits to their users such as high protein transmission and rapid preservative recovery. DFL is ideal for sterilizing filtration of biopharmaceutical grade fluids. Solutions with active ingredients are carefully filtered throughout DFL's compact design. Each product includes a Certificate of Test for bacterial retention and fabrication integrity.

Validated sterilizing grade membranes for the most cost effective filtration of a wide range of liquids such as buffers, tissue culture media, and others

Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 1700 cm² EFA, ½ in. hose barb connections, pre-sterilized by gamma irradiation product photo

Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 1700 cm² EFA, ½ in. hose barb connections, pre-sterilized by gamma irradiation

Product ID: KA3V002PV6S
Unit of Measure
1/EA
Min Order Qty
1
Membrane Material
Polyvinylidene fluoride (PVDF)
Effective Filtration Area (Metric)
1700 cm²
See All Attributes

This product is currently not available. Please contact us for more information.

Supor® EKV membrane in Kleenpak™ capsule, 0.2 µm removal rating, 1500 cm² EFA, ½ in. hose barb connections, suitable for gamma irradiation product photo

Supor® EKV membrane in Kleenpak™ capsule, 0.2 µm removal rating, 1500 cm² EFA, ½ in. hose barb connections, suitable for gamma irradiation

Product ID: KA3EKVP6G
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
0.2 µm
Membrane Material
Polyethersulfone (PES)
Effective Filtration Area
1500 cm²
Sterilization Option(s)
Suitable for Gamma Irradiation, Suitable for Autoclave
Inlet Connection
½ in (13 mm) hose barb
See All Attributes
Supor® EKV membrane in Kleenpak™ capsule, 0.2 µm removal rating, 1500 cm² EFA, ½ in. hose barb connections, pre-sterilized by gamma irradiation product photo

Supor® EKV membrane in Kleenpak™ capsule, 0.2 µm removal rating, 1500 cm² EFA, ½ in. hose barb connections, pre-sterilized by gamma irradiation

Product ID: KA3EKVP6S
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
0.2 µm
Membrane Material
Polyethersulfone (PES)
Effective Filtration Area
1500 cm²
Sterilization Option(s)
Provided Pre-Sterilized by Gamma Irradiation
Inlet Connection
½ in (13 mm) hose barb
See All Attributes

Applications/Use

Oil and Gas:

  • Upstream - Injection water & SRU, offshore boiler water, offshore produced water and onshore surface discharged water
  • Midstream – Process water

Specifications

 

Filter Grades: 1, 3, 5, 10, 20, 25, 30, 40, 50, 75, 100, 200 µm

 

Materials of Construction

 

Filter Media: Bleached FDA-listed cotton, standard cotton, natural cotton, FDA-listed polypropylene, standard polypropylene

 

Material Selection Guide

Filter Medium Premium Cotton1 Standard Cotton Natural Cotton Premium Polypropylene1 Standard Polypropylene

 

Maximum Temperature

Electrolytic Tin Plated Steel Core 300°F (149°C) 300°F (149°C) 300°F (149°C) 275°F (135°C) 275°F (135°C)
Stainless Steel Core 300°F (149°C) 300°F (149°C) 300°F (149°C) 275°F (135°C) 275°F (135°C)
Polypropylene Core 140°F (60°C) 140°F (60°C) 140°F (60°C) 140°F (60°C) 140°F (60°C)

 

Compatibility with:

Food Excellent NR NR Excellent NR
Beverages Excellent NR NR Excellent NR
Potable Water Excellent NR NR Excellent NR
Organic Solvents Excellent Excellent Excellent Good Good
Oils Excellent Excellent Excellent Fair Excellent
Organic Acids Good Good Good Excellent Excellent
Alkalis Good Good Good Excellent Excellent
Oxidizing Agents Fair Fair Fair Good Good
Steam NR NR NR Fair NR
Strong Inorganic Acids NR NR NR Excellent Excellent
Dilute Inorganic Acids Fair Fair Fair Excellent Excellent
Micro-organism Resistance Poor Poor Poor Excellent Excellent

 

1 - FDA-listed materials. NR = Not Recommended