String-wound Depth Filter Cartridges

A Long Service Life and High Contaminant Loading Capacity 

Pall’s string-wound depth filters are designed for advanced and efficient particulate removal performance and high contaminant holding capacity. Compared to traditional polypropylene or polyester materials, these filter cartridges use woven media yarn around the core and have high chemical, temperature, and process fluid compatibility. Available with 10+ different medium options these cartridges are also an economical low-cost choice compared to depth and pleated style filters. 

Order Products

Filter Media

Kieselguhr, Perlite and Cellulose Fibers

Seitz® K Series Depth Filter Sheets, K 300 600x612

Product ID: B01092
Unit of Measure
50/EA
Min Order Qty
50
Filter Media
Kieselguhr, Perlite and Cellulose Fibers
Filter Area (Imperial)
3.95 ft²
Filter Area (Metric)
0.37 m²
Hot Water Sanitization
90 °C
Recommended max.dp
3 bar
Size (Imperial)
23.6 x 24.1 in
See All Attributes

Seitz® K Series Depth Filter Sheets, K 250 600x612

Product ID: B01091
Unit of Measure
50/EA
Min Order Qty
50
Filter Media
Kieselguhr, Perlite and Cellulose Fibers
Filter Area (Imperial)
3.95 ft²
Filter Area (Metric)
0.37 m²
Hot Water Sanitization
90 °C
Recommended max.dp
3 bar
Size (Imperial)
23.6 x 24.1 in
See All Attributes

Seitz® K Series Depth Filter Sheets, K 200 600x612

Product ID: B01090
Unit of Measure
50/EA
Min Order Qty
50
Filter Media
Kieselguhr, Perlite and Cellulose Fibers
Filter Area (Imperial)
3.95 ft²
Filter Area (Metric)
0.37 m²
Hot Water Sanitization
90 °C
Recommended max.dp
3 bar
Size (Imperial)
23.6 x 24.1 in
See All Attributes

Seitz® K Series Depth Filter Sheets, K 250 400X400

Product ID: B01106
Unit of Measure
100/EA
Min Order Qty
100
Filter Media
Kieselguhr, Perlite and Cellulose Fibers
Filter Area (Imperial)
1.73 ft²
Filter Area (Metric)
0.16 m²
Hot Water Sanitization
90 °C
Recommended max.dp
3 bar
Size (Imperial)
15.8 x 15.8 in
See All Attributes

Seitz® K Series Depth Filter Sheets, K 300 400x400

Product ID: B01105
Unit of Measure
100/EA
Min Order Qty
100
Filter Media
Kieselguhr, Perlite and Cellulose Fibers
Filter Area (Imperial)
1.73 ft²
Filter Area (Metric)
0.16 m²
Hot Water Sanitization
90 °C
Recommended max.dp
3 bar
Size (Imperial)
15.8 x 15.8 in
See All Attributes

Seitz® K Series Depth Filter Sheets, SEITZ-EK 1 400x400

Product ID: B07569
Unit of Measure
100/EA
Min Order Qty
100
Filter Media
Kieselguhr, Perlite and Cellulose Fibers
Filter Area (Imperial)
1.73 ft²
Filter Area (Metric)
0.16 m²
Hot Water Sanitization
90 °C
Recommended max.dp
1.5 bar
Size (Imperial)
15.8 x 15.8 in
See All Attributes
Seitz® K Series Depth Filter Sheets, K 100 600x612 product photo

Seitz® K Series Depth Filter Sheets, K 100 600x612

Product ID: B07567
Unit of Measure
50/EA
Min Order Qty
50
Filter Media
Kieselguhr, Perlite and Cellulose Fibers
Filter Area (Imperial)
3.95 ft²
Filter Area (Metric)
0.37 m²
Hot Water Sanitization
90 °C
Recommended max.dp
3 bar
Size (Imperial)
23.6 x 24.1 in
See All Attributes

Seitz® K Series Depth Filter Sheets, KS 50 400x400

Product ID: B07571
Unit of Measure
100/EA
Min Order Qty
100
Filter Media
Kieselguhr, Perlite and Cellulose Fibers
Filter Area (Imperial)
1.73 ft²
Filter Area (Metric)
0.16 m²
Hot Water Sanitization
90 °C
Recommended max.dp
1.5 bar
Size (Imperial)
15.8 x 15.8 in
See All Attributes

Seitz® K Series Depth Filter Sheets, K 200 400x400

Product ID: B07628
Unit of Measure
100/EA
Min Order Qty
100
Filter Media
Kieselguhr, Perlite and Cellulose Fibers
Filter Area (Imperial)
1.73 ft²
Filter Area (Metric)
0.16 m²
Hot Water Sanitization
90 °C
Recommended max.dp
3 bar
Size (Imperial)
15.8 x 15.8 in
See All Attributes

Seitz® K Series Depth Filter Sheets, SEITZ-EK 400x400

Product ID: B07570
Unit of Measure
100/EA
Min Order Qty
100
Filter Media
Kieselguhr, Perlite and Cellulose Fibers
Filter Area (Imperial)
1.73 ft²
Filter Area (Metric)
0.16 m²
Hot Water Sanitization
90 °C
Recommended max.dp
1.5 bar
Size (Imperial)
15.8 x 15.8 in
See All Attributes

Seitz® K Series Depth Filter Sheets, for Microorganism Reduction, KS 80 400x400

Product ID: B07572
Unit of Measure
100/EA
Min Order Qty
100
Filter Media
Kieselguhr, Perlite and Cellulose Fibers
Filter Area (Imperial)
1.73 ft²
Filter Area (Metric)
0.16 m²
Hot Water Sanitization
90 °C
Recommended max.dp
1.5 bar
Size (Imperial)
15.8 x 15.8 in
See All Attributes

Seitz® K Series Depth Filter Sheets, K 200 200x200

Product ID: B08274
Unit of Measure
400/EA
Min Order Qty
400
Filter Media
Kieselguhr, Perlite and Cellulose Fibers
Filter Area (Imperial)
0.42 ft²
Filter Area (Metric)
0.04 m²
Hot Water Sanitization
90 °C
Recommended max.dp
3 bar
Size (Imperial)
7.8 x 7.8 in
See All Attributes

Description

String-wound filter cartridges are a type of depth filter cartridge that is made by weaving yarn (cotton, glass fiber, polypropylene, polyester, nylon, and polyphenylene sulfide (PPS))around a core usually of 304 SS or 316 SS. 

Product Highlights:
  • High chemical and temperature compatibility
  • 10+ different medium options 
  • Economical choice

Specifications

Product Attributes Values
String-Wound Filters Filter Medium
  • Bleached cotton
  • Standard cotton
  • Natural cotton
  • Glass fiber
  • Heat purified glass fiber
  • Premium polypropylene
  • Standard polypropylene
  • Rayon
  • Polyester
  • Nylon
  • Acrylic
  • Polyphenylene sulfide (PPS)
  • Polytetrafluoroethylene (fluoropolymer)

Filter Grade Range

0.5 μm to 350 μm
Length 10.2 cm (4 in.) to 127 cm (50 in.)

Applications/Uses

Pall’s string-wound filter cartridges are used for a variety of applications, including chemicals and polymer, oil and gas, and microelectronics.

Chemicals and Polymer

  • Midstream Process Water 
  • Poly Commodity Raw Material (Fluids)
  • Poly Commodity Intermediates (Fluids)
  • Poly Engineered & Special Raw Material (Fluids)
  • Poly Engineered & Special Intermediate (Fluids)

Oil and Gas

  • Upstream Offshore Boiler Water
  • Upstream Offshore Produced Water
  • Upstream Onshore Produced Water
  • Upstream Onshore Surface Discharged Water
  • Midstream Process Water
  • Upstream Injection Water & SRU

Microelectronics

  • Acid etch systems - including Piranha Etch Solvent Strip applications
  • Most aggressive and/or high temperature acids or solvents

Chemicals

  • Polishing of chemical solutions
  • Bulk industrial chemicals
  • Solvents
  • Acids
  • Bases
  • Monomers
  • Process and cooling water

Magnetic Coatings

  • Audio
  • Video & computer tape
  • Floppy discs
  • Computer hard discs
  • Solvents

Photographic

  • Photo emulsions
  • Chemicals
  • Wash & rinse water

Oil Production

  • Well completion fluids
  • Water flood

Air & Gas

  • Compressed air
  • Instrument air
  • Nitrogen
  • Hydrogen
  • Helium
  • Freon
  • Most corrosive gases

Other

  • Solution mining
  • Deep well disposal
  • Paint
  • Ink & coatings
  • Lubricating oils
  • Electropolishing solutions
  • Plating solutions
  • Pigments & dyes
  • Cleaning fluids
  • Adhesives

FAQs

1. Which are the two series that Pall offers for string-wound filters?

Pall offers string-wound filters in the DFT Classic and Encore Series.

 

2. Why choose Pall’s string-wound depth filters?

Pall’s string-wound depth filters are designed for advanced and efficient particulate removal performance and high contaminant holding capacity. These filter cartridges have high chemical, temperature, and process fluid compatibility compared to traditional polypropylene or polyester materials and come with 10+ different medium options.