Order Products
Family
Ultipor
Nominal Length (Metric)
20.32 cm
Nominal OD (Imperial)
4.2 in
Ultipor Glass Fiber 7µm Nitrile Seal 8in 20.32cm length
1/EA
1
For Upstream, Polymer & Ink Filtration
Profile UP pleated depth filters are constructed using Pall's proprietary method of varying fiber diameter continuously to create a tapered pore filter medium. This makes the elements ideal for viscous fluids and dispersions in addition to those many applications where long service life is desired.
Given the unique medium construction and a proprietary crescent-shaped pleat structure, the pressure drop of the Profile UP filters is as low as half that of higher area pleated filters and as low as one-fifteenth that of conventional depth filters. Consequently, Profile UP filters provide an exceptional service life.
Family
Ultipor
Nominal Length (Metric)
20.32 cm
Nominal OD (Imperial)
4.2 in
Why choose Profile Up pleated depth filter cartridges?
These filters are thicker than conventional pleated filters and are optimized for gel removal and sharp, distinct particle removal.
Additional benefits include:
Product Highlights:
Performance Characteristics
Cartridge Grade Liquid Service Removal Rating in Microns (µm) at % Efficiency | Clean Pressure Drop Aqueous Service MBARD / LPM (PSID / GPM) Per 10-inch Element2 | ||
---|---|---|---|
90% | 99.98% | ||
020 | <1.0 | 3.2 | 2.37 / 0.13 |
045 | 1.2 | 4.5 | 1.55 / 0.085 |
060 | 2.5 | 6.0 | 0.64 / 0.035 |
100 | 4.3 | 10.0 | 0.55 / 0.030 |
200 | 11.0 | 20.0 | 0.46 / 0.025 |
300 | 17.0 | 30.0 | 0.36 / 0.020 |
400 | 19.0 | 40.0 | 0.27 / 0.015 |
500 | 25.0 | 50.0 | <0.18 / 0.010 |
700 | 35.0 | – 1 | <0.18 / 0.010 |
1000 | 60.0 | – 1 | <0.18 / 0.010 |
Operating Characteristics
Maximum Differential Pressure3 (BARD / PSID) | Temperature (°C / °F) |
---|---|
4.1 / 60 | 30 / 86 |
3.4 / 50 | 50 / 122 |
2 / 30 | 70 / 158 |
1 / 15 | 80 / 176 |
1 Precision evaluation of the 99.98% removal efficiency for these coarse grades is not possible with the OSU test procedure utilized.
2 Pressure drop in PSI per GPM for a single 10-inch cartridge. For multiple number of elements, divide by the number of cartridges. For fluids other than water, multiply the value calculated by the fluid's viscosity measured in centipoise.
3 Based upon polypropylene core collapse.