Beschreibung
Athalon™ maximum-life filters deliver the highest level of sustained fluid system protection, across all applications, regardless of severity.
Featuring an industry leading BetaX(C)=2000* filter efficiency; the highest rated filter performance available today.
(* per ISO 16889)
- Keeps fluids the cleanest, longest, for the greatest value
- Provides consistent, reliable, protection of system components over the full service life of the filter element
- Rapidly achieves and sustains required fluid system cleanliness
- Delivers maximum filter capacity in the smallest footprint
- Prevents electrostatic discharge from damaging your filter and degrading your fluid
Features
- Patented Ultipleat (laid-over pleat) filter medium pack
- Pall Stress-Resistant Technology (SRT) Media
- Coreless filter element configuration
- Low clean pressure drop for low energy operation
Spezifikationenn
Specifications Filter Housing
- Flows to 230 L/min (60 US gpm)
- Pressures to 414 bar (6000 psi)
- Port Size 1” and 1¼”
- Rated Fatigue Pressure:
0-240 bar (3500 psi) per NFPA T2.06.01R2-2001 CAT C/90/*(1 million cycles), verified by testing at 0-280 bar (4050 psi) for 1 million cycles. Contact Pall for applications with higher pressures at lower cycles. Not applicable for D and F Port options. - Filter Element Burst Pressure:
10 bard (150 psid) - Fluid Compatibility:
Compatible with all petroleum oils and most water glycols, water-oil emulsions, and synthetic hydraulic and lubrication fluids - Temperature Range:
Fluorocarbon Seals:
-29 ?C to 120 ?C (-20 ?F to 248 ?F)
60 ?C (140 ?F) maximum in HWCF or water glycol fluids - Bypass Valve Setting:
4.5 bard (65 psid) - Indicator Pressure Setting:
3.5 bard (50 psid) - Materials of Construction:
Head and Cover: Ductile Cast Iron
Tube: Carbon steel - Filter Element :
Inorganic fibers impregnated and bonded with epoxy resins. Polymer endcaps. Anti-static media design
Dimensional Drawings
Dimensions in mm (inches)
Length Code | Overall length mm (in) |
Cover Service Element Removal Clearance mm (in) |
Head Service Element Removal Clearance mm (in) |
Empty Weight kg (lb) |
04 | 261.0 (10.28) | 147 (5.79) | 143 (5.63) | 10.3 (22.7) |
08 | 376.5 (14.82) | 248 (9.76) | 243 (9.57) | 12.1 (26.7) |
13 | 511.1 (20.12) | 383 (15.08) | 380 (14.96) | 14.7 (32.4) |
20 | 681.3 (26.82) | 553 (21.77) | N/A | 17.8 (39.2) |
Leistung
Pressure Drop Information
Housing pressure drop using fluid with 0.9 S.G.
Housing pressure drop is directly proportional to specific gravity.
Element Pressure Drop
210 Series Filter Elements – bard/1000 L/min (psid/US gpm)Length Code | AZ | AP | AN | AS | AT |
04 | 20.07 (1.102) | 8.51 (0.467) | 5.72 (0.314) | 3.55 (0.195) | 2.69 (0.029) |
08 | 9.93 (0.545) | 4.21 (0.231) | 2.83 (0.155) | 1.76 (0.096) | 1.33 (0.073) |
13 | 5.95 (0.327) | 2.52 (0.139) | 1.70 (0.093) | 1.05 (0.058) | 0.80 (0.044) |
20 | 3.95 (0.217) | 1.68 (0.092) | 1.13 (0.062) | 0.70 (0.038) | 0.53 (0.029) |
Multiply actual flow rate times factor in table below to determine pressure drop with fluid at 32 cSt (150 SUS), 0.9 S.G. Correct for other fluids by multiplying new viscosity in cSt/32 (SUS/150) x new S.G./0.9. Note: factors are per 1000 L/min and per 1 US gpm
Sample ΔP calculation
UH210 Series 13” length housing with C20 BSPP ports using AN grade media. Operating conditions 100 L/min flow rate using a hydraulic fluid of 50 cSt and specific gravity (s.g.) 1.2.Total Filter ΔP
= ΔP housing + ΔP element
= (0.13 x 1.2/0.9) bard (housing)
+ ((100 x 1.70/1000) x 50/32 x 1.2/0.9) bard (element)
= 0.17 (housing) + 0.35 bard (element)
= 0.52 bard (7.6 psid)