Beschreibung
Pall’s Medallion™ HP line of liquid/gas coalescers is designed to meet the needs of the process industry, offering high performance and reduced operation and maintenance costs. Medallion coalescers can be used for many applications to enhance process performance.
Pall offers a full range of product options designed to meet various performance needs.
Features, Advantages and Benefits of the Pall Medallion Liquid/Gas Coalescers
Features | Advantages | Benefits |
Medallion media pack | • High liquid removal per unit area • Fewer elements needed • Minimized vessel diameter | • Reduced need for an upstream bulk separator • Reduced capital and installation costs |
High-capacity large diameter element | • Fewer elements needed for a given gas flow rate • Minimized vessel diameter | • Reduced capital and installation costs • Smaller space required for installation |
High-effective filtration area | • Fewer element changeouts needed • High solids removal efficiency | • Lower operating and maintenance costs |
High-efficiency media and equipment | • Consistently high liquid removal efficiency • Reduced liquid losses • Optimum protection of downstream equipment | • Lower maintenance costs and availability |
Anwendungen
- Inlet/Outlet Reciprocating Compressor
- Turbine Protection
- Inlet/Outlet Amine Contactor
- Low and Ultra-low NOx Burner Protection
- Inlet/Outlet Glycol Contactor
- Gas Separation Membrane Protection
- Mole Sieve Protection
- Sales Gas
- Mercury Removal Catalyst Protection
- Transmission Pipeline Gas
- Pipeline Metering / Compression Stations
Spezifikationenn
Materials of construction
• Glass Microfiber Medium | ||
• A Style: | Compatible with most applications | |
SOE P/N: | CS604LGT2H13 | |
DOE P/N: | CS604LGT2DH13 | |
• B Style: | Compatible with Amine and Ammonia gas | |
SOE P/N: | CS604LGBT2H13 | |
DOE P/N: | CS604LGBT2DH13 | |
• End caps: | 300 series SS |
Leistung
Performance data
• Liquids: | 99.999% at 0.3 micron per DOP test |
1 ppb downstream liquids (CAGI)1 | |
• Solids: | 99.7% for particles >0.3 micron per NaCl test |
• Max Burst Pressure: | 50 psid (3.45 bard) |
• Maximum operating temperatures: | |
180°F (82.2 °C) in gas service with no water present | |
140°F (60.0 °C) in gas service with water present |
1 Per the modified ANSI/CAGI-400-1999 test procedure
Typ
Rezensionen
Earn 10% off* your next order online by leaving a review of this product. Please login to your account to leave a review. We appreciate and value your feedback.