Profile® UP filters are 63.5 mm (2.5 in.) diameter pleated polypropylene cartridges. The absolute-rated filter medium is constructed using Pall's proprietary method of varying fiber diameter continuously to create a tapered pore filter medium.
Given the unique medium construction and a proprietary crescent-shaped pleat structure, the pressure drop of the Profile UP filters is as low as half that of higher area pleated filters and as low as one-fifteenth that of conventional depth filters. Consequently, Profile UP filters provide exceptional service life. Profile UP filters can best be described as Pall's Ultipleat® filters utilizing Profile depth filter media. As a result, these filters are thicker than conventional pleated filters and are optimized for gel removal and sharp, distinct particle removal. This makes the elements ideal for viscous fluids and dispersions in addition to those many applications where long service life is desired.
For P and W options, the filters are constructed entirely of FDA-listed materials and the absolute rating of the filter is based upon the widely accepted modified Oklahoma State University (OSU) F-2 Filter Performance (Beta Rating) Test.
Given the unique medium construction and a proprietary crescent-shaped pleat structure, the pressure drop of the Profile UP filters is as low as half that of higher area pleated filters and as low as one-fifteenth that of conventional depth filters. Consequently, Profile UP filters provide exceptional service life. Profile UP filters can best be described as Pall's Ultipleat® filters utilizing Profile depth filter media. As a result, these filters are thicker than conventional pleated filters and are optimized for gel removal and sharp, distinct particle removal. This makes the elements ideal for viscous fluids and dispersions in addition to those many applications where long service life is desired.
For P and W options, the filters are constructed entirely of FDA-listed materials and the absolute rating of the filter is based upon the widely accepted modified Oklahoma State University (OSU) F-2 Filter Performance (Beta Rating) Test.
Features | Advantages | Benefits |
Absolute-rated medium |
|
|
Pleated depth filter medium |
|
|
Crescent-shaped medium configuration |
|
|
Polypropylene filter construction |
|
|
Housing Information
Housings are available in either polypropylene, PVC, CPVC, PVDF, carbon steel, or stainless steel and can accommodate 1-356, 10 inch modules per housing (one 40 inch filter represents four 10 inch modules).Performance Characteristics
Cartridge Grade | Liquid Service Removal Rating in Microns (μm) at % Efficiency | Clean Pressure Drop Aqueous Service MBARD / LPM (PSID / GPM) Per 10 inch Element2 | |
90% | 99.98% | ||
020 | <1.0 | 3.2 | 2.37 / 0.13 |
045 | 1.2 | 4.5 | 1.55 / 0.085 |
060 | 2.5 | 6.0 | 0.64 / 0.035 |
100 | 4.3 | 10.0 | 0.55 / 0.030 |
200 | 11.0 | 20.0 | 0.46 / 0.025 |
300 | 17.0 | 30.0 | 0.36 / 0.020 |
400 | 19.0 | 40.0 | 0.27 / 0.015 |
500 | 25.0 | 50.0 | <0.18 / 0.010 |
700 | 35.0 | – 1 | <0.18 / 0.010 |
1000 | 60.0 | – 1 | <0.18 / 0.010 |
Operating Characteristics
Maximum Differential Pressure3 (BARD / PSID) | Temperature (°C / °F) |
4.1 / 60 | 30 / 86 |
3.4 / 50 | 50 / 122 |
2 / 30 | 70 / 158 |
1 / 15 | 80 / 176 |
1 Precision evaluation of the 99.98% removal efficiency for these coarse grades is not possible with the OSU test procedure utilized.
2 Pressure drop in PSI per GPM for a single 10 inch cartridge. For multiple number of elements, divide by the number of cartridges. For fluids other than water, multiply the value calculated by the fluid's viscosity measured in centipoise.
3 Based upon polypropylene core collapse.
Filter Cartridges
Removal Rating Microns (μm) | PUY Series | AB Series4 Code 18 | AB Series Code 3 |
2.0 | PUY ● UY020 ▲ | AB ● UY02018 ■ | AB ● UY0203 ■ |
4.5 | PUY ● UY045 ▲ | AB ● UY04518 ■ | AB ● UY0453 ■ |
6.0 | PUY ● UY060 ▲ | AB ● UY06018 ■ | AB ● UY0603 ■ |
10.0 | PUY ● UY100 ▲ | AB ● UY10018 ■ | AB ● UY1003 ■ |
20.0 | PUY ● UY200 ▲ | AB ● UY20018 ■ | AB ● UY2003 ■ |
30.0 | PUY ● UY300 ▲ | AB ● UY30018 ■ | AB ● UY3003 ■ |
40.0 | PUY ● UY400 ▲ | AB ● UY40018 ■ | AB ● UY4003 ■ |
50.0 | PUY ● UY500 ▲ | AB ● UY50018 ■ | AB ● UY5003 ■ |
70.0 | PUY ● UY700 ▲ | AB ● UY70018 ■ | AB ● UY7003 ■ |
100.0 | PUY ● UY1000 ▲ | AB ● UY100018 ■ | AB ● UY10003 ■ |
Removal Rating Microns (μm) | AB Series Code 7 | AB Series Code 8 | Kleen-Change® 700 Series5,6 |
2.0 | AB ● UY0207 ■ | AB ● UY0208 ■ | LY7 ● UY020G23 |
4.5 | AB ● UY0457 ■ | AB ● UY0458 ■ | LY7 ● UY045G23 |
6.0 | AB ● UY0607 ■ | AB ● UY0608 ■ | LY7 ● UY060G23 |
10.0 | AB ● UY1007 ■ | AB ● UY1008 ■ | LY7 ● UY100G23 |
20.0 | AB ● UY2007 ■ | AB ● UY2008 ■ | LY7 ● UY200G23 |
30.0 | AB ● UY3007 ■ | AB ● UY3008 ■ | LY7 ● UY300G23 |
40.0 | AB ● UY4007 ■ | AB ● UY4008 ■ | LY7 ● UY400G23 |
50.0 | AB ● UY5007 ■ | AB ● UY5008 ■ | LY7 ● UY500G23 |
70.0 | AB ● UY7007 ■ | AB ● UY7008 ■ | LY7 ● UY700G23 |
100.0 | AB ● UY10007 ■ | AB ● UY10008 ■ | LY7 ● UY1000G23 |
4 Available only as 762 mm (30 inch) or 1016 mm (40 inch) continuous length elements.
5 Kleen-Change 700 series assemblies are only available with 254 mm (10 inch) or 508 mm (20 inch) cartridges.
6 Kleen-Change 100 series assemblies are available.
Code ● | Cartridge length mm / in. |
1 | 254 / 10 |
2 | 508 / 20 |
3 | 762 / 30 |
4 | 1016 / 40 |
Code ■ | O-Ring option |
H4 | Silicone-standard for Code 3, 7 and 8 |
H | Fluorocarbon elastomer |
J | Ethylene propylene |
H13 | Nitrite, standard for Code 18 |
Code ▲ | Gasket option |
J | Ethylene propylenestandard |
H13 | Nitrite |
H4 | Silicone |
H | Fluorocarbon elastomer |
Y1 | Polypropylene |
Code ▲ | Optional configuration |
SI | Spring attached to filter top |
Ordering Details
Style | Description |
PUY Series |
|
AB Code 18 Series |
|
AB Code 3 Series |
|
AB Code 7 Series |
|
AB Code 8 Series |
|
Kleen-Change 700 Assembly |
|
Notes:
a. The AB Code 18, 3, 7 and 8 elements are recommended if the cartridges be heated and then cooled by 20 °C (68 °F) prior to filtration.
b. The fit-up of AB Code 18 filters must be confirmed to ensure that the top the filter will meet with the housing lid or internal plate in the case of back pressure. This will ensure the cartridge O-ring seal is maintained.
c. The choice of an AB Code 3, 7 or 8 element will depend on the filter housing currently used in retrofit applications.
* Tri-Clamp is a trademark of Ladish Co., Tri-Clover Division.
Chem Intermediate Product (Other), Chem Raw Material - Liquid, Amine/Benfield /Other Solvent loop, Chemicals Raw Material / Gas/Air, Poly Cmdty Intermediate (Fluids), Poly Cmdty Raw Material (Fluids), Poly Engrd & Spcl Intermediate (Fluids), Poly Engrd & Spcl Raw Material (Fluids), Chem Final Product (Liquid)
Chemicals, Chemicals, Petro Chem, Chemicals, Polymer, Polymer, Polymer, Polymer, Chemicals
Earn 10% off* your next order online by leaving a review of this product. Please login to your account to leave a review. We appreciate and value your feedback.
*Subject to Terms and Conditions.