8600/04/06 Series Rotolok Filter Assemblies product photo Primary L

8600/04/06 Series Rotolok Filter Assemblies

Featuring Coreless Element Technology
Flows to 40 gpm (145 L/min)
Pressures to 600 psi (41 bar)
Port sizes: 3/4" and 1"

Please Note:
The 8600 series filter assemblies are no longer available and are being replaced with Ultipleat® UR219 Filter Assemblies

All replacement filter elements, differential pressure indicators and sealkits remain available for this series. See 'Ordering Information' tab above for details of spares.


Contact Us
* Required

설명

Featuring Coreless Element Technology
Flows to 40 gpm (145 L/min)
Pressures to 600 psi (41 bar)
Port sizes: 3/4" and 1"

Please Note:
The 8600 series filter assemblies are no longer available and are being replaced with Ultipleat® UR219 Filter Assemblies

All replacement filter elements, differential pressure indicators and sealkits remain available for this series. See 'Ordering Information' tab above for details of spares.

규격사양

Features

  • Optional Differential Pressure Devices
  • Full Flow Fast Response Bypass Valve
  • Easy Service Rotolok Ring
  • Drawn Steel Bowl
  • Optional Anti-Backflow Valve (not shown). Prevents drainage of reservoir or lines where filter is mounted below fluid level
  • High Strength Fatigue Rated Housing
  • Gray Cast Iron Head
  • O-Ring Seals
  • Ultipor® III Element

Maximum Allowable Working Pressure:

600 psi (41 bar)

Fatigue Pressure Rating:

600 psi (41 bar)
(2,000,000 cycles to 600 psi)

Temperature Range:

Nitrile seals -45°F to 225°F (-43°C to 107°C)
Fluorocarbon seals -20°F to 250°F (-29°C to 120°C)
140°F (60°C) maximum in HWCF or water-glycol fluids

Dry Weights:

R length– 8 lbs. (3.6 kg)
S length– 9 lbs. (4.1 kg)
T length- 11 lbs. (5 kg)

Filter Element Collapse Pressure:

9600–290 psid (20 bar)
9604–150 psid (10 bar)
9606–600 psid (207 bar)

Caution:

120 psi (8 bar) maximum for 8600 Series non-bypass valve options (prevents possible filter element collapse).

Dimensional Drawings

 

성능

Element Pressure Drop Factor

Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G.
Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

9600/9604* Series Element P factor (psid/gpm)
 
LengthKZKPKNKSKT
           
4" 0.81 0.36 0.29 0.22 0.15
           
8" 0.46 0.20 0.17 0.12 0.09
           
13" 0.27 0.12 0.07 0.07
0.05
 
*9604 not available in 4" length.

 

9606 Series Element P factor (psid/gpm)
 
LengthDS
   
4" 0.17
   
8" 0.09
   
13" 0.05
 

종류

Housings, Vessels, or Assemblies

주문정보

Assembly P/N:     

H

860

 

 

 

 

Table1

 

Table2
Table3
Table4
Table5
Table6
Table7
Table8
 
 


Element P/N:       

HC 960

F

 

 

 

 

 

 
Table2
 
Table5
Table6
Table1
 

 

 

 



Note:
Choose from the options in the following tables to compile the specific Product Number.

Table 1: Seal Options
 
CodeSeals
   
H Nitrile
   
Z Fluorocarbon
 


 

TABLE 2: ELEMENT OPTIONS
 
CODE
OPTION
   
0
Standard
   

4

Coreless
   

6*

High collapse
 
* 8606 is available with non-bypass valve options and 'DS' filter media only.



 

TABLE 3: PORT STYLE OPTIONS
 
CODE
PORT STYLE
   
A
SAE J514 straight thread
   
B
NPT tapered pipe thread
 

 

TABLE 4: PORT SIZE OPTIONS
 
CODE
SIZE
   
12
3/4"
   

16

1"
 

 

TABLE 5: FILTER ELEMENT OPTIONS
 

Code

ß 200

ßx(c) = 1000

     

KZ

<1

2.5

     

KP

3

5

     

KN

6

7

     

KS

12

12

     

KT

25

22

     

DS*

12

10

 
* 8606 only.


 

TABLE 6: LENGTH OPTIONS*
 

Assembly Code

Element Code**

   

R***

4

   

S

8

   

T

13

 
* Use code in second column for element part no.
** Nominal length in inches.
***Not available for 8604 series/9604 element.


 

TABLE 7: BYPASS VALVE OPTIONS
 
CODE
DESCRIPTION
   

A

25 psid
   

B

50 psid
   

W*

Non-bypass
   

8

25 psid with ABFV**
   

9

50 psid with ABFV**
   

V*

Non-bypass with ABFV**
 
* Not available for 8604.
** ABFV– Anti-backflow valve.

TABLE 8: Differential Pressure Device Options
 

Code

Description

   

P

Visual indicator with thermal lockout

   

D

Visual indicator with no thermal lockout

   

L

Electrical switch (SPDT) with 6" leads

   

T

Electrical switch with DIN connector

   

M

'T' type switch with matching wiring cap

   

S

Electrical switch with MS receptacle

   

V

Combined visual /electrical with DIN connector

   

B

Plug in place of indicator

 

적용분야

Auto LOH for Stamping, Auto LOH for Stamping, Heavy Lubrication, Heavy Lubrication, Material Handling, Material Handling, Auto Painting/Coating Zinc Phosphate Bath, Auto Painting/Coating Zinc Phosphate Bath, Midstream Process Water, Midstream Process Water, Midstream Process Water, Midstream Process Water, Midstream Process Water, Midstream Process Water, Midstream Process Water, Midstream Process Water, Midstream Process Water, Mining Equipment Gear Case, Mining Equipment Hydraulic Fluid, Mining Euqipment Lube Oil - on & off board, Mining Final Product (Post Smelt/Burn off Impurities), Mining Final Product (Slurry), Mining Wastewater, Municiple Mining Water [Rinsing] , Heavy Fuel, Heavy Hydraulic, Heavy Lubrication, Medium & Light Fuel, Medium & Light Hydraulic, Medium & Light Lubrication, Pulp&Paper Bleach Chemical Prep, Pulp&Paper LOH, Pulp&Paper Machine Process Application, Pulp&Paper Paper Coating, Pulp&Paper Pulp Screening

영역

Automotive, Automotive, Mobile OEM, Mobile OEM, Primary Metals, Primary Metals, General Industrial, General Industrial, General Industrial, General Industrial, General Industrial, General Industrial, General Industrial, General Industrial, General Industrial, General Industrial, General Industrial, Mining, Mining, Mining, Mining, Mining, Mining, Mining, Mobile OEM, Mobile OEM, Mobile OEM, Mobile OEM, Mobile OEM, Mobile OEM, Pulp & Paper, Pulp & Paper, Pulp & Paper, Pulp & Paper, Pulp & Paper

Reviews