UT610 Series Athalon™ Tank Mounted Filters product photo Primary L

UT610 Series Athalon™Tank Mounted Filters

Athalon™ maximum-life filters deliver the highest level of sustained fluid system protection, across all applications, regardless of severity.

Featuring an industry leading BetaX(C)=2000* filter efficiency; the highest rated filter performance available today.
(* per ISO 16889)

  • Keeps fluids the cleanest, longest, for the greatest value
  • Provides consistent, reliable, protection of system components over the full service life of the filter element
  • Rapidly achieves and sustains required fluid system cleanliness 
  • Delivers maximum filter capacity in the smallest footprint
  • Prevents electrostatic discharge from damaging your filter and degrading your fluid

Features

  • Patented Ultipleat (laid-over pleat) filter medium pack
  • Pall Stress-Resistant Technology (SRT) Media
  • Coreless filter element configuration
  • Low clean differential pressure for low energy operation


Contact Us
* Required

설명

Athalon™ maximum-life filters deliver the highest level of sustained fluid system protection, across all applications, regardless of severity.

Featuring an industry leading BetaX(C)=2000* filter efficiency; the highest rated filter performance available today.
(* per ISO 16889)

  • Keeps fluids the cleanest, longest, for the greatest value
  • Provides consistent, reliable, protection of system components over the full service life of the filter element
  • Rapidly achieves and sustains required fluid system cleanliness 
  • Delivers maximum filter capacity in the smallest footprint
  • Prevents electrostatic discharge from damaging your filter and degrading your fluid

Features

  • Patented Ultipleat (laid-over pleat) filter medium pack
  • Pall Stress-Resistant Technology (SRT) Media
  • Coreless filter element configuration
  • Low clean differential pressure for low energy operation

규격사양

Specifications Filter Housing

  • Flows to 1140 L/min (300 US gpm)
  • Pressures to 10 bar (145 psi)
  • Inlet Port Size: 2½” and 3” Outlet Port Size: 3” (all options)
  • Rated Fatigue Pressure:
    0 - 10 bar (145 psi) per NFPA T2.06.01R2-2001 CAT C/90/*, verified by testing at 0 - 12 bar (174 psi) for ¼ million cycles.
  • Filter Element Burst Pressure:10 bard (150 psid)
  • Fluid Compatibility:
    Compatible with all petroleum oils and most water glycols, water-oil emulsions, and synthetic hydraulic and lubrication fluids
  • Temperature Range:
    Fluorocarbon Seals:
    -29 ?C to 120 ?C (-20 ?F to 248 ?F)
    60 ?C (140 ?F) maximum in HWCF or water glycol fluids
  • Bypass Valve Setting:
    3.4 bard (50 psid)
    1.7 bard (25 psid)
    Available with or without anti-backflow valve
  • Indicator Pressure Setting:
    2.5 Bard (36 psid)
    1.1 bard (16 psid)

  • Materials of Construction:Head, cover and tube: Aluminium
  • Filter Element :
    Inorganic fibers impregnated and bonded with epoxy resins. Polymer endcaps. Anti-static media design

Dimensional Drawings

Dimensions in mm (inches)
 
Length Code Overall length mm (in) Cover Service Element Removal Clearance mm (in) Empty Weight kg (lb)
20 767.1 (30.20) 548 (21.57) 13.6 (30)
40 1275.1 (50.20) 1056 (41.57) 15.1 (33.3)
 

UT610-dimension-img

성능

Pressure Drop Information

Housing pressure drop using fluid with 0.9 S.G.

Housing pressure drop is directly proportional to specific gravity.
UT610-graph-img

Element Pressure Drop

610 Series Filter Elements – bard/1000 L/min (psid/US gpm)

 
Length Code AZ AP AN AS AT
20 1.31 (0.072) 0.56 (0.030) 0.43 (0.023) 0.31 (0.017) 0.19 (0.011)
40 0.70 (0.038) 0.30 (0.016) 0.23 (0.013) 0.17 (0.009) 0.10 (0.006)
 

Multiply actual flow rate times factor in table below to determine pressure drop with fluid at 32 cSt (150 SUS), 0.9 S.G. Correct for other fluids by multiplying new viscosity in cSt/32 (SUS/150) x new S.G./0.9. Note: factors are per 1000 L/min and per 1 US gpm

Sample ΔP calculation

UT610 Series 20” length housing with F40 (2½” split flange) ports using AN grade media. Operating conditions 600 L/min flow rate using a hydraulic fluid of 50 cSt and specific gravity (s.g.) 1.2.

Total Filter ΔP

= ΔP housing + ΔP element
= (0.18 x 1.2/0.9) bard (housing)
+ ((600 x 0.23/1000) x 50/32 x 1.2/0.9) bard (element)
= 0.24 (housing) + 0.29 bard (element)
= 0.53 bard (7.7 psid)

종류

Housings, Vessels, or Assemblies

적용분야

Auto LOH for Stamping, Auto LOH-Filling Lines, Mining Equipment Gear Case, Mining Equipment Hydraulic Fluid, Mining Euqipment Lube Oil - on & off board, Heavy Hydraulic, Heavy Lubrication, Medium & Light Hydraulic, Medium & Light Lubrication, Coolants / Bearing Lubrication, Drives Gear Box + Roll Housing, Forging / Extrusion, Gear Box / Bearing, Gear Box / Morgoil, Material Directional Control, Material Handling, Non Contact, Medium & Light Hydraulic, Medium & Light Lubrication

Reviews

Earn 10% off* your next order online by leaving a review of this product. Please login to your account to leave a review. We appreciate and value your feedback.

*Subject to Terms and Conditions.