설명
Featuring Coreless Element Technology
Flows to 300 gpm (1135 L/min)Pressures to 400 psi (28 bar)
Port sizes: 1-1/2", 2 and 2-1/2"
With Dual Manifold:
Flows to 600 gpm (2270 L/min)
Port Size: 3"
The 8300 series filter assemblies are no longer available and are being replaced with Ultipleat® UR619 Filter Assemblies
All replacement filter elements, differential pressure indicators and sealkits remain available for this series. See 'Ordering Information' tab above for details of spares.
규격사양
Features
- T-Handle Easy Service Cover
- Bleed Port Plug
- O-Ring Seals
- Optional Differential Pressure Devices
- Anodized Aluminum Alloy-Head, Tube and Cover
- Fill Port
- Full Flow Fast Response Bypass Valves
- Ultipor® III Element
- Drain Port and Plug
Maximum Acceptable Working Pressure:
400 psi (28 bar)Fatigue Pressure Rating:
(NFPA/T2.6.1-1974 category 2/90)330 psi (23 bar)
Typical Burst Pressure:
2100 psi (145 bar)Temperature Range:
Nitrile seals -45°F to 225°F (-43°C to 107°C)Fluorocarbon seals -20°F to 250°F (-29°C to 120°C)
140°F (60°C) maximum in HWCF or water-glycol fluids
Dry Weights:
U length– 45 lbs. (20.5 kg)X length– 92 lbs. (42 kg)
Filter Element Collapse Pressure:
8300/04/14–150 psid (10 bar)8310–100 psid (7 bar)
Caution:
120 psi (8 bar) maximum for 8300/04/14 Series80 psi (5.5 bar) maximum for 8310
Series non-bypass valve options (prevents possible filter element collapse).
Dimensional Drawings
성능
Figure 1. Housing Pressure Drop using fluid with 0.9 S.G. Housing Pressure drop is directly proportional to specific gravity. |
|
Figure 2. Bypass Valve Pressure Drop using fluid with 0.9 S.G. Bypass valve pressure drops are directly proportional to specific gravity. |
|
Element Pressure Drop Factor
Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G.Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.
8300 Series Element P factor (psid/gpm) | |||||
Length | KZ | KP | KN | KS | KT |
---|---|---|---|---|---|
16" | 0.078 | 0.034 | 0.028 | 0.021 | 0.014 |
39" | 0.039 | 0.015 | 0.012 | 0.009 | 0.006 |
|
8304 Series Element P factor (psid/gpm) | |||||
Length | KZ | KP | KN | KS | KT |
---|---|---|---|---|---|
16" | 0.101 | 0.049 | 0.041 | 0.031 | 0.022 |
39" | 0.038 | 0.018 | 0.015 | 0.012 | 0.008 |
|
8310/14 Series Element P factor (psid/gpm) | |||||
Length | KZ | KP | KN | KS | KT |
---|---|---|---|---|---|
16" | 0.089 | 0.047 | 0.040 | 0.031 | 0.022 |
39" | 0.034 | 0.018 | 0.015 | 0.012 | 0.008 |
|
종류
Housings, Vessels, or Assemblies
주문정보
Assembly P/N: | H | 83 |
| |||||||||
|
| Table1 |
| Table2 | Table3 | Table4 | Table5 | Table6 | Table7 | Table8 | Table9 |
Element P/N: | HC 83 | F |
|
|
|
| ||||
|
| Table2 | Table5 | Table6 | Table1 |
|
|
|
Note: Choose from the options in the following tables to compile the specific Product Number.
TABLE 1: SEAL OPTIONS | |
Code | Seals |
---|---|
H | Nitrile |
Z | Fluorocarbon |
TABLE 2: ELEMENT OPTIONS | |
Code | Option |
---|---|
00 | Standard capacity |
04 | Coreless, standard capacity |
10 | High capacity |
14 | Coreless, high capacity |
TABLE 3: PORT STYLE OPTIONS | |
Code | Port Style |
---|---|
A | SAE J514 straight thread |
D | Flange SAE J518c-Code 61 |
TABLE 4: PORT SIZE OPTIONS | ||
Code | Size | Style Availability |
---|---|---|
24 | 1-1/2" | A, D |
32 | 2" | A, D |
40 | 2-1/2" | D |
TABLE 5: FILTER ELEMENT OPTIONS | ||
Code | ßx 200 | ßx(c)=1000 |
---|---|---|
KZ | <1 | 2.5 |
KP | 3 | 5 |
KN | 6 | 7 |
KS | 12 | 12 |
KT | 25 | 22 |
TABLE 6: LENGTH OPTIONS* | |
Assembly Code | Element Code** |
---|---|
U | 16 |
X | 39 |
* Use Code in second column for element part no. |
TABLE 7: BYPASS VALVE OPTIONS | |
Code | Description |
---|---|
A | 25 psid |
B | 50 psid |
Y | Non-bypass with 16 psid indicator |
N | Non-bypass with 35 psid indicator |
TABLE 8: DIFFERENTIAL PRESSURE DEVICE OPTIONS | |
Code | Description |
---|---|
P | Visual indicator with thermal lockout |
D | Visual indicator with no thermal lockout |
L | Electrical switch (SPDT) with 6" leads |
T | Electrical switch with DIN connector |
M | 'T' type switch with matching wiring cap |
S | Electrical switch with MS receptacle |
V | Combined visual/electrical with DIN connector
|
B | Plug in place of indicator |
2 | 'P' and 'L' |
3 | 'P' and 'S' |
Dual Manifold P/N: H 8300-SP2A3
Table1
Mounting Bracket P/N: 1129210
적용분야
Auto LOH for Stamping, Heavy Lubrication, Material Handling, Auto Painting/Coating Zinc Phosphate Bath, Midstream Process Water, Midstream Process Water, Midstream Process Water, Midstream Process Water, Midstream Process Water, Mining Equipment Gear Case, Mining Equipment Hydraulic Fluid, Mining Euqipment Lube Oil - on & off board, Mining Final Product (Post Smelt/Burn off Impurities), Mining Final Product (Slurry), Mining Wastewater, Municiple Mining Water [Rinsing] , Coolants / Bearing Lubrication, Drives Gear Box + Roll Housing, Forging / Extrusion, Gear Box / Bearing, Gear Box / Morgoil, Material Directional Control, Material Handling, Non Contact, Quenching / Cleaning, Roll Bite (Safety Filter), Shape + Material Handling, Pulp&Paper Bleach Chemical Prep, Pulp&Paper LOH, Pulp&Paper Machine Process Application, Pulp&Paper Paper Coating, Pulp&Paper Pulp Screening, Auto Painting/Coating Zinc Phosphate Bath, Medium & Light Hydraulic, Medium & Light Lubrication, Midstream Process Water
영역
Automotive, Mobile OEM, Primary Metals, General Industrial, General Industrial, General Industrial, General Industrial, General Industrial, General Industrial, Mining, Mining, Mining, Mining, Mining, Mining, Mining, Primary Metals, Primary Metals, Primary Metals, Primary Metals, Primary Metals, Primary Metals, Primary Metals, Primary Metals, Primary Metals, Primary Metals, Primary Metals, Pulp & Paper, Pulp & Paper, Pulp & Paper, Pulp & Paper, Pulp & Paper, General Industrial, General Industrial, General Industrial, General Industrial
Reviews
Earn 10% off* your next order online by leaving a review of this product. Please login to your account to leave a review. We appreciate and value your feedback.