설명
Versalon™ T200 tank mounted filters deliver high-performance contaminant protection for lube and hydraulic systems in an economical package tailored for Industrial and Mobile OEMs. The T200 features Coralon® filter elements, with world-class BetaX(C)≥1000 filtration rating.
규격사양
Notes and Specifications
Filter Housing
- Maximum Flow Rate (8-inch assembly):
150 L/min (39 USgpm ) - Maximum Allowable Working Pressure:
10 bar (145 psi) - Fluid Compatibility:
Compatible with all petroleum oils, water glycols, water-oil emulsions, and most synthetic hydraulic and lubrication fluids - Temperature Range:
Nitrile Seals: -29°C to 100°C (-20°F to 212°F) 50°C (122°F) maximum in HWCF or water-glycol fluids - Bypass Valve Settings:
3.4 bar (50 psi) - Visual Gauge Settings:
Visual gauge with green at <2.4 bar="" 35="" psi="" and="" red="">2.4 bar (35 psi) - Materials of Construction:
Head: Aluminum alloy
Cover: Polyamide
Canister: Polyamide
Filter Element
- Filter Element Collapse Pressure:
10 bar (145psid ) - Filter Element Construction:
Inorganic fibers impregnated and bonded with epoxy resins. Corrosion protected carbon steel core and end caps
성능
Pressure Drop Information
Housing pressure drop using fluid with 0.9 S.G.
Housing pressure drop is directly proportional to specific gravity
Element Pressure Drop
HCT200 Filter Elements – bard/1000 L/min (
Length Code | CS | CT |
04 | 6.0 (0.33) | 3.92 (0.21) |
08 | 3.33 (0.18) | 2.04 (0.11) |
Multiply actual flow rate times factor in
Note: factors are per 1000 L/min and per 1 US
Sample ΔP calculation
T200 Series 8 inch length with C16 ports using CS grade media. Operating conditions 100 L/min flow rate using a hydraulic fluid at 45 cST and specific gravity (s.g.) 1.2
Total Filter ΔP
= ΔP housing + ΔP element= (0.32 x 1.2/0.9) bard (housing)
+ ((100 x 3.3/1000) x 45/30 x 1.2/0.9) bard (element)
= 0.43 bard (housing) + 0.66 bard (element)
= 1.09 bard (15.8 psid)
종류
주문정보
T-200_Series_2
Table 1: Housing Port Style Options
Code | Port Style |
C | BSP threads to ISO 228 |
U2 | JIS B0203 tapered pipe thread |
Table 2: Housing Port Size Options
Code | Port Size |
08 | 1/2” |
12 | 3/4” |
16 | 1" |
Table 3: Indicator Port Location
Code | Gauge Position |
1 | Position 90 degrees counter clockwise from |
2 | Position 90 degrees clockwise from |
3 | Position opposite from inlet port |
Table 4: Filter Element Options
Code | Rating (μm) βX(C)≥1000 |
CS | 12 |
CT | 22 |
Table 5: Length Options
Housing Code | Element Code | Length mm (in) |
R | 04 | 102 (4) |
S | 08 | 203 (8) |
Table 6: Bypass Valve
Code | Bypass Valve Type |
B | 3.4 ± 0.3 bar (49 ± 6 psi) |
적용분야
영역
Reviews
Earn 10% off* your next order online by leaving a review of this product. Please login to your account to leave a review. We appreciate and value your feedback.