PhaseSep® EL Coalescers
Separate Liquid/Liquid Dispersions on Harsh, Hot, or Dirty Streams
Optimize Coalescer and/or Pre-filter Life
Pall’s new PhaseSep EL coalescer provides chemical/petrochemical, oil & gas and refinery plants’ aggressive or high temperature streams with improved separation efficiency via a coarse coalescer format, differentiating from bulk separators and commodity coalescers by achieving low OPEX and lower CAPEX with high efficiency contaminant separation. The PhaseSep EL coalescer is expected to perform well in applications with the presence of high solids and difficult oil/water emulsions.
PhaseSep EL Coalescer vs. ‘Original’ PhaseSep Coalescer
- Lower OPEX from longer pre-filter and coalescer life due to coarser ratings
- Directly retrofittable with PhaseSep coalescer
- Uses new medium specifically selected to yield desired performance in target applications
The PhaseSep EL system is typically a multiple-stage system, starting with prefiltration to remove particulate matter, followed by either a one-stage horizontal coalescer or two-stage integrated vertical coalescer/separator stack to separate the two liquid phases. PhaseSep EL coalescers will remove oil and grease to a level of 20 ppmw, or free water to a level as low as 15 ppmv and be effective over a wide range of conditions such as inlet liquid contaminant concentration as high as 0.1% and interfacial tension less than 10 dynes/cm1.
The PhaseSep EL coalescer system is available in two different housing configurations. Both configurations begin with a filtration stage to remove solid contaminants.
Table 1. Coalescer System Selection Guide
Process Condition | Recommended Product |
The dispersed phase fluid is aqueous and a horizontal footprint is acceptable | PhaseSep EL coalescer in a horizontal housing without separator |
The dispersed phase fluid is oil and the continuous phase fluid is aqueous | |
The dispersed phase fluid is aqueous and minimal footprint is required | PhaseSep EL coalescer/separator stack in a vertical housing |
PhaseSep EL Coalescer - Horizontal Housing Configuration
In a horizontal housing, the liquid/liquid mixture enters the coalescing element and flows inside-to-outside, small liquid dispersed phase droplets suspended in the continuous phase come together, or coalesce, as the mixture moves through the PhaseSep EL coalescer. The large coalesced droplets of the dispersed phase separate by gravity in the horizontal housing and are removed. The size of the housing is a function of the flow rate, IFT, viscosity, and specific gravity of the liquids.
PhaseSep EL Coalescer/Separator Stack - Vertical Housing Configuration
Contaminant-free liquid and large droplets of the dispersed phase flow toward the separator located directly below the coalescer stage. The flow is outside-toinside. The separator medium is hydrophobic preventing the aqueous phase from entering the separator. Only the non-aqueous continuous phase fluid flows through the separator. The two liquids are removed by separate drain connections.
1 Performance can vary depending on application
설명
Pall’s new PhaseSep EL coalescer provides chemical/petrochemical, oil & gas and refinery plants’ aggressive or high temperature streams with improved separation efficiency via a coarse coalescer format, differentiating from bulk separators and commodity coalescers by achieving low OPEX and lower CAPEX with high efficiency contaminant separation. The PhaseSep EL coalescer is expected to perform well in applications with the presence of high solids and difficult oil/water emulsions.
PhaseSep EL Coalescer vs. ‘Original’ PhaseSep Coalescer
- Lower OPEX from longer pre-filter and coalescer life due to coarser ratings
- Directly retrofittable with PhaseSep coalescer
- Uses new medium specifically selected to yield desired performance in target applications
The PhaseSep EL system is typically a multiple-stage system, starting with prefiltration to remove particulate matter, followed by either a one-stage horizontal coalescer or two-stage integrated vertical coalescer/separator stack to separate the two liquid phases. PhaseSep EL coalescers will remove oil and grease to a level of 20 ppmw, or free water to a level as low as 15 ppmv and be effective over a wide range of conditions such as inlet liquid contaminant concentration as high as 0.1% and interfacial tension less than 10 dynes/cm1.
The PhaseSep EL coalescer system is available in two different housing configurations. Both configurations begin with a filtration stage to remove solid contaminants.
Table 1. Coalescer System Selection Guide
Process Condition | Recommended Product |
The dispersed phase fluid is aqueous and a horizontal footprint is acceptable | PhaseSep EL coalescer in a horizontal housing without separator |
The dispersed phase fluid is oil and the continuous phase fluid is aqueous | |
The dispersed phase fluid is aqueous and minimal footprint is required | PhaseSep EL coalescer/separator stack in a vertical housing |
PhaseSep EL Coalescer - Horizontal Housing Configuration
In a horizontal housing, the liquid/liquid mixture enters the coalescing element and flows inside-to-outside, small liquid dispersed phase droplets suspended in the continuous phase come together, or coalesce, as the mixture moves through the PhaseSep EL coalescer. The large coalesced droplets of the dispersed phase separate by gravity in the horizontal housing and are removed. The size of the housing is a function of the flow rate, IFT, viscosity, and specific gravity of the liquids.
PhaseSep EL Coalescer/Separator Stack - Vertical Housing Configuration
Contaminant-free liquid and large droplets of the dispersed phase flow toward the separator located directly below the coalescer stage. The flow is outside-toinside. The separator medium is hydrophobic preventing the aqueous phase from entering the separator. Only the non-aqueous continuous phase fluid flows through the separator. The two liquids are removed by separate drain connections.
1 Performance can vary depending on application
응용분야
Not all coalescers provide a high efficiency quantitative removal of dispersed liquid contaminants and can handle emulsions with low interfacial tensions (IFTs). For example, conventional cartridge and mesh pack coalescers made of glass fiber media begin to lose efficiency when the IFT of the emulsion gets below 20 dynes/cm. In contrast, the new PhaseSep EL coalescer from Pall is constructed of a high-efficiency, engineered polymer medium, making it well suited for numerous aggressive service liquid/liquid separation applications with low IFTs.
- Separation of pyrolysis gas from quench water in ethylene plants, especially on tar-laden streams found in gas crackers
- Removal of hydrocarbons from rich side amine streams
- Hot hydrocarbon condensate dewatering to protect stabilizer columns
- Hydrocarbon removal from sour water on streams with wide-ranging pH variation
- De-oiling of produced water streams
- Ensure final product quality specifications are maintained
Product Benefits
Features | Advantages | Benefits |
High Performance, Coarse Grade engineered polymer medium |
|
|
|
|
|
|
|
|
Non-disarming coalescing medium |
|
|
|
|
|
Availability of a High Performance Integrated Stack Design – Coalescer and Separator |
|
|
Compatibility
The PhaseSep EL coalescer is compatible with hydrocarbon fuels and fuel additives, alkanes, olefins, aromatics, ethylene glycol, trace amounts of IPA and methanol, water in the pH range of 1-14, alkanol amine – water solutions (MEA, DEA, MDEA, and fluids generally compatible with epoxy, fluorocarbon or 304 SS. For compatibility information with a specific chemical, please contact your Pall representative or distributor.
1 Performance can vary depending on application
규격사양
Maximum operating temperature: | 104.4 °C / 220 °F for most organic fluids. A soak test in the process fluid is recommended for temperatures up to 204 °C / 400 °F |
Maximum differential pressure: | 3.5 bard / 50 psid at 21 °C / 70 °F |
Oil in Water Performance1 | < 20 ppmw oil & grease* per EPA1664 or ALPHA5520B |
Water in Oil Performance1 | < 15 ppmw based on AquaGlo (free water) detection, up to 0.1% water |
Recommended change-out: | 1.0 bard/15 psid at 21 °C / 70 °F |
PhaseSep EL Coalescer Reduces Costs
Begin reducing your capital and operating costs today. Contact your local Pall distributor or call Pall directly to arrange for a budgetary quotation and pilot test of the PhaseSep EL coalescer technology.
종류
주문정보
Part Number | Description | Outer Diameter (cm/in) nominal | Length (cm/in) nominal |
LCS2ELPH | PhaseSep EL 20" Coalescer | 10.7/4.2 (flange) 9.53/3.75 (main element) |
50.8/20 |
LCS4ELPH | PhaseSep EL 40" Coalescer | 10.7/4.2 (flange) 9.53/3.75 (main element) |
101.6/40 |
LSS2F2H | Separator | 9.53/3.75 | 50.8/20 |
Reviews
Earn 10% off* your next order online by leaving a review of this product. Please login to your account to leave a review. We appreciate and value your feedback.