Fluoro-Plus™ II PFA Filter Housings product photo Primary L

Fluoro-Plus™ II PFA Filter Housings

PFA single cartridge filter housing for critical chemical applications in electronics
  • High purity 100% fluoro-polymer construction
  • All wetted parts are fluoro-polymers (PVDF non-wetted)
  • Stationary bowl with rotating locking ring ensures positive closure seal and easy filter replacement
  • Designed for higher temperature and pressure applications
  • Choice of two filter inlet/outlet configurations for easy installation
  • Packaged in a cleanroom environment
  • Full 1 in. / 25 mm inlet/outlet ports for increased flow available in 10 in. / 254 mm, 20 in. / 508 mm and 30 in. / 762 mm


Contact Us
* Required

설명

PFA single cartridge filter housing for critical chemical applications in electronics
  • High purity 100% fluoro-polymer construction
  • All wetted parts are fluoro-polymers (PVDF non-wetted)
  • Stationary bowl with rotating locking ring ensures positive closure seal and easy filter replacement
  • Designed for higher temperature and pressure applications
  • Choice of two filter inlet/outlet configurations for easy installation
  • Packaged in a cleanroom environment
  • Full 1 in. / 25 mm inlet/outlet ports for increased flow available in 10 in. / 254 mm, 20 in. / 508 mm and 30 in. / 762 mm

규격사양

Materials of Construction

  • Housing: High purity PFA head, bowl and plugs
  • O-ring: FEP encapsulated fluoroelastomer
  • Locking Ring: PVDF (non-wetted part)

Connections

  • Inlet / Outlet:
    • 34 in. or 1 in. flare
    • Flowell1
    • Pillar2
    • 34 in. or 1 in. butt weld pipe
  • Vent and Drain:
    • 14 in. flare
    • 38 in. flare
    • 14 in. butt weld pipe
    • 14 in. female NPT
    • 14 in. closed end
  • Cartridge Connection: Double 222 O-ring

Operating Conditions

  • Maximum Operating Pressure
    • 50 psig @ 194 °F / 3.4 bar @ 90 °C
    • 100 psig @ 77 °F / 6.9 bar @ 25 °C
Note: Maximum operating pressure ratings are vessel ratings only. Safe operating temperature and pressure will depend on filter cartridge and O-ring used. Product not rated for gas service. For inquiries on compatibility, contact Pall Microelectronics.
1 Flowell is a product of Flowell Co., Ltd.
2 Pillar Fitting is a trademark of Nippon Pillar Packing Co., Ltd.

성능

Pressure Drop vs. Liquid Flow Rate3


Pressure Drop vs. Liquid Flow Rate
3 For liquids other than water, multiply the pressure drop by the specific gravity of the fluid. Pressure drop curve represents an empty housing.

종류

Housings, Vessels, or Assemblies

추가 정보

Dimensions



Dimensional Data

Description Housing Style Length (L)
(in. / mm)
Width (W)
(in. / mm)
T S T S
Fluoro-Plus II PFA
10 in. / 254 mm housing with:
34 in. Butt weld pipe fitting 16.0 / 406 17.3 / 439 9.0 / 229 5.9 / 150
34 in. Flare style fitting 19.5 / 495 16.3 / 414 10.5 / 267 5.9 / 150
1 in. Butt weld pipe fitting 16.0 / 406 14.3 / 363 9.0 / 229 5.9 / 150
1 in. Flare style fitting 19.5 / 495 16.3 / 414 11.0 / 279 5.9 / 150
Fluoro-Plus II PFA
20 in. / 508 mm housing with:
34 in. Butt weld pipe fitting 25.7 / 653 9.0 / 229
34 in. Flare style fitting 29.3 / 744 10.5 / 267
1 in. Butt weld pipe fitting 25.7 / 653 9.0 / 229
1 in. Flare style fitting 29.3 / 744 11.0 / 279
Fluoro-Plus II PFA
30 in. / 762 mm housing with:
34 in. Butt weld pipe fitting 35.5 / 902 9.0 / 229
34 in. Flare style fitting 39.1 / 993 10.5 / 267
1 in. Butt weld pipe fitting 35.5 / 902 9.0 / 229
1 in. Flare style fitting 39.1 / 993 11.0 / 279

주문정보

This information is a guide to the part number structure and possible options. For availability of specific options and housing details, please contact Pall.

Example Part Number: FP T 20 34 FW 38 FLC ( See bold references in tables below)

Part Number:
FP < End Configuration Code from Table 1 > < Length Code from Table 2 > < Inlet/Outlet Size Code from Table 3 > < Inlet/Outlet Style Code from Table 4 > < Vent/Drain Size Code from Table 5 > < Vent/Drain Style Code from Table 6 >

Table 1 - End Configurations

Code End Configurations
T T-style
S Straight (in-line)

Table 2 - Lengths

Code Lengths
10 10 in. bowl
20 20 in. bowl (T-style only)
30 30 in. bowl (T-style only)

Table 3 - Inlet/Outlet Sizes

Code Inlet/Outlet Sizes
34 34 in.
1 1 in.

Table 4 - Inlet/Outlet Styles

Code Inlet/Outlet Styles
BW Butt weld
FL Flare
FG 1 in. Flange (T-style only)
FW Flowell
PL Pillar style fittings
FLC Flare cap installed

Table 5 - Vent/Drain Sizes

Code Vent/Drain Sizes
14 14 in.
38 38 in. (Flare only)

Table 6 - Vent/Drain Styles

Code Vent/Drain Styles
BW Butt weld
FL Flare
CE Closed end
FP Female pipe thread
FW Flowell
PL Pillar style fittings
FLC Flare cap installed

Part Number  
ACS0655AA Spanner wrench
T8316030 Mounting clamp and bolt assembly

적용분야

Chemicals

영역

Semiconductor

Reviews

Earn 10% off* your next order online by leaving a review of this product. Please login to your account to leave a review. We appreciate and value your feedback.