Profile® II Filter Elements product photo Primary L

Profile® II Filter Elements

Profile® II filters are all polypropylene. The elements have an absolute-rated downstream section, and a continuously graded pore size upstream section, which increases service life many-fold.

The materials of construction - chemically resistant polypropylene – permit application in a very wide range of corrosive and non-corrosive fluids. The fibers in Profile II filters may be considered continuous. No binder resin is used – the fibers are “bonded” by intertwining during the manufacturing process. As a result, Profile II filters show no media migration.

The Profile II filter has numerous applications in a broad range of industries that include chemical, petrochemical, photochemical, pharmaceutical, biological, electronic, magnetic tape, electroplating, food and beverage, cosmetic, veterinary, medical and fermentation industries. They are used as both prefilters and as final filters.



Contact Us
* Required

설명

Profile® II filters are all polypropylene. The elements have an absolute-rated downstream section, and a continuously graded pore size upstream section, which increases service life many-fold.

The materials of construction - chemically resistant polypropylene – permit application in a very wide range of corrosive and non-corrosive fluids. The fibers in Profile II filters may be considered continuous. No binder resin is used – the fibers are “bonded” by intertwining during the manufacturing process. As a result, Profile II filters show no media migration.

The Profile II filter has numerous applications in a broad range of industries that include chemical, petrochemical, photochemical, pharmaceutical, biological, electronic, magnetic tape, electroplating, food and beverage, cosmetic, veterinary, medical and fermentation industries. They are used as both prefilters and as final filters.

규격사양

Sizes

The Profile II RF, and RMF Series filter elements are 21⁄2² O.D. and are available in one piece 10², 20², 30², and 40² length modules. Profile II elements are also available in 23⁄4² diameter AB Code 3, 7 and 8 Series configurations. See Bulletin PRO 400 for further details.

성능

Operating Characteristics

Recommended maximum pressure differential is 60 psi up to 30°C (86°F), 50 psi up to 50°C (122°F), 30 psi up to 70°C (158°F), and 15 psi up to 82°C (180°F).

For applications where the filters are heated for any reason above 122°F (50°C) and the temperature is then reduced by 36°F (20°C) or more, AB Series elements are recommended. See Bulletin PRO 400 and PRE-1 for more detailed information.


Table I. Profile II Cartridge Grades And Their Characteristics

 
Cartridge Grade Removal Ratings Typical Clean Pressure Drop Typical Aqueous Flow (GPM/10² Cartridge)
Liquid Service Gaseous Service Liquid Service Gaseous Service
Rating in μm At
99.9%
% Efficiency
100%
DOP (0.3 μm)(1)
Efficiency %
Aqueous Pressure
drop(2)
CFM of air per PSI per 10² cartridge(3)
003* ‹0.5(4) ‹0.5(4) >99.9999 3.5 2.3 1 - 2.5
003* ‹0.5(4) ‹0.5(4) >99.9999 2.8 2.7 1 - 2.5
010 ‹0.5(4) 1 >99.9999 2.6 3.6 1 - 3
030 2.5 3 >99.9999 1.5 6.4 2 - 5
050 4 5 >99.9999 0.8 11.0 3 - 8
070 6 7 >99.9999 0.5 17.0 5 - 12
100 9 10 99.2 0.3 29.0 6 - 15
120 11 12 96.5 0.2 36.0 6 - 15
150 13 15 88 0.15 44.0 8 - 15
200 18 20 84.8 0.10 75.0 10 - 15
300 26 30 67 0.08 119.0 10 - 15
400 35 40 48.3 0.05 207.0 10 - 15
700 70 (5) 34 ‹ 0.05 415.0 10 - 15
900 90(4) (5) 25 ‹0.05 640.0 10 - 15
1200 120(4) (5) 10 ‹0.05 1000.0 10 - 15
 
1Air flow used for these data was 20 cfm/10² module, except grade 700, which was run at 4 cfm.
2Pressure drop is PSI per GPM for a single 10² module. For multiple elements, divide by number of modules. For fluids other than water, multiply by viscosity in centipoise.
3For longer modules, increase the flow rates listed in proportion. The flow rates listed do not take into account pressure losses due to flow in the internal diameter of the element, which becomes significant above about 40 to 60 cfm.
4Extrapolated values.
5Precise evaluation of the 100% removal efficiency for these coarse grades is not possible with test procedure utilized.
*AB style only.

종류

Filter Cartridges

주문정보

Table II. Standard Configurations of Profile II Cartridges

 
100% Removal Rating, μm Profile II Element Part Numbers
For General Application For General Application Rating, μm Including in situ Steam Sterilization, and in situ Hot Water Sanitizing(1)
RF Series AB Series
0.3* (2) ----------------  
0.5 (2) R ■ ▲ F005 ● AB ▲ Y003 ♦ ▼ ★
1 R ■ ▲ F010 ● AB ▲ Y005 ♦ ▼ ★
3 R ■ ▲ F030 ● AB ▲ Y010 ♦ ▼ ★
5 R ■ ▲ F050 ● AB ▲ Y030 ♦ ▼ ★
7 R ■ ▲ F070 ● AB ▲ Y050 ♦ ▼ ★
10 R ■ ▲ F100 ● AB ▲ Y070 ♦ ▼ ★
12 R ■ ▲ F120 ●  
15 R ■ ▲ F150 ●  
20 R ■ ▲ F200 ●  
30 R ■ ▲ F300 ●  
40 R ■ ▲ F400 ●  
70 R ■ ▲ F700 ●  
90 R ■ ▲ F900 ●  
120 R ■ ▲ F1200 ●  
 


 
 
Gasket Code
None No Symbol
Elastomeric Material**
 


 
 
Nominal Length, In. Code
10 1
20 2
30 3
40 4
 


 
 
Gasket Material Code
Alloy of Polypropylene and Ethylene Propylene Diene Monomer (EPDM) H21
 


 
 
Application Code
Pharmaceutical P
Other Omit
 


 
 
O-ring Option Code
Silicone H4
Viton A H
Ethylene-Propylene J
 


         
 
Cartridge Diameter
O.D., In.
Adaptor Configuration Number of O-rings O-ring Size FDA Listed Materials of Construction Code
234 Flat Top 2 222 Yes 3
234 Finned Top, Locking Tabs 2 226 Yes 7
234 Finned Top 2 222 Yes 8
 


Table III. Housings For Profile II Elements

 
Type Of Element Housing Available
R [] F Series and RM [] F Series See Housing Data Sheets H2, H13, H14, H15, H16, H17, H18, H19, H36, H37, H38 and H39 for Pall housings specifically designed to accommodate these elements. R F Series elements may also be used with competitor built housings which accommodate 21⁄2² O.D. x 10², 20², 30², and 40² nominal length elements; however, sealing may be marginal for grades 030 (3 μm absolute) and finer.
AB [] Y Series, Code 3, 7 and 8 See Housing Data Sheets H22, H26, H28, H29, H30, H31, H32, and H35.
 


1Only P grade AB Series elements may be in-situ steam sterilized.
2Extrapolated valves.
* AB style only.
** Provides a positive sealing surface to eliminate potential fluid bypass in competitive housings with blunt knife edges.
*** When the M symbol is selected the part number must end in H21 code.

적용분야

LNG Acid Gas, Midstream Process Water, Refinery Amine Systems, Upstream Injection Water & SRU, Midstream Acid Gas, Midstream Glycol Filtration

영역

Midstream, Midstream, Refinery, Upstream, Midstream, Midstream

Reviews

Earn 10% off* your next order online by leaving a review of this product. Please login to your account to leave a review. We appreciate and value your feedback.

*Subject to Terms and Conditions.