설명
Profile® II filters are all polypropylene. The elements have an absolute-rated downstream section, and a continuously graded pore size upstream section, which increases service life many-fold.
The materials of construction - chemically resistant polypropylene – permit application in a very wide range of corrosive and non-corrosive fluids. The fibers in Profile II filters may be considered continuous. No binder resin is used – the fibers are “bonded” by intertwining during the manufacturing process. As a result, Profile II filters show no media migration.
The Profile II filter has numerous applications in a broad range of industries that include chemical, petrochemical, photochemical, pharmaceutical, biological, electronic, magnetic tape, electroplating, food and beverage, cosmetic, veterinary, medical and fermentation industries. They are used as both prefilters and as final filters.
규격사양
Sizes
The Profile II RF, and RMF Series filter elements are 21⁄2² O.D. and are available in one piece 10², 20², 30², and 40² length modules. Profile II elements are also available in 23⁄4² diameter AB Code 3, 7 and 8 Series configurations. See Bulletin PRO 400 for further details.
성능
Operating Characteristics
Recommended maximum pressure differential is 60 psi up to 30°C (86°F), 50 psi up to 50°C (122°F), 30 psi up to 70°C (158°F), and 15 psi up to 82°C (180°F).
For applications where the filters are heated for any reason above 122°F (50°C) and the temperature is then reduced by 36°F (20°C) or more, AB Series elements are recommended. See Bulletin PRO 400 and PRE-1 for more detailed information.
Table I. Profile II Cartridge Grades And Their Characteristics
Cartridge Grade | Removal Ratings | Typical Clean Pressure Drop | Typical Aqueous Flow (GPM/10² Cartridge) | |||
Liquid Service | Gaseous Service | Liquid Service | Gaseous Service | |||
Rating in μm At 99.9% | % Efficiency 100% | DOP (0.3 μm)(1) Efficiency % | Aqueous Pressure drop(2) | CFM of air per PSI per 10² cartridge(3) | ||
003* | ‹0.5(4) | ‹0.5(4) | >99.9999 | 3.5 | 2.3 | 1 - 2.5 |
003* | ‹0.5(4) | ‹0.5(4) | >99.9999 | 2.8 | 2.7 | 1 - 2.5 |
010 | ‹0.5(4) | 1 | >99.9999 | 2.6 | 3.6 | 1 - 3 |
030 | 2.5 | 3 | >99.9999 | 1.5 | 6.4 | 2 - 5 |
050 | 4 | 5 | >99.9999 | 0.8 | 11.0 | 3 - 8 |
070 | 6 | 7 | >99.9999 | 0.5 | 17.0 | 5 - 12 |
100 | 9 | 10 | 99.2 | 0.3 | 29.0 | 6 - 15 |
120 | 11 | 12 | 96.5 | 0.2 | 36.0 | 6 - 15 |
150 | 13 | 15 | 88 | 0.15 | 44.0 | 8 - 15 |
200 | 18 | 20 | 84.8 | 0.10 | 75.0 | 10 - 15 |
300 | 26 | 30 | 67 | 0.08 | 119.0 | 10 - 15 |
400 | 35 | 40 | 48.3 | 0.05 | 207.0 | 10 - 15 |
700 | 70 | —(5) | 34 | ‹ 0.05 | 415.0 | 10 - 15 |
900 | 90(4) | —(5) | 25 | ‹0.05 | 640.0 | 10 - 15 |
1200 | 120(4) | —(5) | 10 | ‹0.05 | 1000.0 | 10 - 15 |
1Air flow used for these data was 20 cfm/10² module, except grade 700, which was run at 4 cfm.
2Pressure drop is PSI per GPM for a single 10² module. For multiple elements, divide by number of modules. For fluids other than water, multiply by viscosity in centipoise.
3For longer modules, increase the flow rates listed in proportion. The flow rates listed do not take into account pressure losses due to flow in the internal diameter of the element, which becomes significant above about 40 to 60 cfm.
4Extrapolated values.
5Precise evaluation of the 100% removal efficiency for these coarse grades is not possible with test procedure utilized.
*AB style only.
종류
주문정보
Table II. Standard Configurations of Profile II Cartridges
100% Removal Rating, μm | Profile II Element Part Numbers | |
For General Application | For General Application Rating, μm Including in situ Steam Sterilization, and in situ Hot Water Sanitizing(1) | |
RF Series | AB Series | |
0.3* (2) | ---------------- | |
0.5 (2) | R ■ ▲ F005 ● | AB ▲ Y003 ♦ ▼ ★ |
1 | R ■ ▲ F010 ● | AB ▲ Y005 ♦ ▼ ★ |
3 | R ■ ▲ F030 ● | AB ▲ Y010 ♦ ▼ ★ |
5 | R ■ ▲ F050 ● | AB ▲ Y030 ♦ ▼ ★ |
7 | R ■ ▲ F070 ● | AB ▲ Y050 ♦ ▼ ★ |
10 | R ■ ▲ F100 ● | AB ▲ Y070 ♦ ▼ ★ |
12 | R ■ ▲ F120 ● | |
15 | R ■ ▲ F150 ● | |
20 | R ■ ▲ F200 ● | |
30 | R ■ ▲ F300 ● | |
40 | R ■ ▲ F400 ● | |
70 | R ■ ▲ F700 ● | |
90 | R ■ ▲ F900 ● | |
120 | R ■ ▲ F1200 ● | |
■ | |
Gasket | Code |
None | No Symbol |
Elastomeric | Material** |
▲ | |
Nominal Length, In. | Code |
10 | 1 |
20 | 2 |
30 | 3 |
40 | 4 |
● | |
Gasket Material | Code |
Alloy of Polypropylene and Ethylene Propylene Diene Monomer (EPDM) | H21 |
▼ | |
Application | Code |
Pharmaceutical | P |
Other | Omit |
★ | |
O-ring Option | Code |
Silicone | H4 |
Viton A | H |
Ethylene-Propylene | J |
♦ | |||||
Cartridge Diameter O.D., In. | Adaptor Configuration | Number of O-rings | O-ring Size | FDA Listed Materials of Construction | Code |
23⁄4 | Flat Top | 2 | 222 | Yes | 3 |
23⁄4 | Finned Top, Locking Tabs | 2 | 226 | Yes | 7 |
23⁄4 | Finned Top | 2 | 222 | Yes | 8 |
Table III. Housings For Profile II Elements
Type Of Element | Housing Available |
R [] F Series and RM [] F Series | See Housing Data Sheets H2, H13, H14, H15, H16, H17, H18, H19, H36, H37, H38 and H39 for Pall housings specifically designed to accommodate these elements. R F Series elements may also be used with competitor built housings which accommodate 21⁄2² O.D. x 10², 20², 30², and 40² nominal length elements; however, sealing may be marginal for grades 030 (3 μm absolute) and finer. |
AB [] Y Series, Code 3, 7 and 8 | See Housing Data Sheets H22, H26, H28, H29, H30, H31, H32, and H35. |
1Only P grade AB Series elements may be in-situ steam sterilized.
2Extrapolated valves.
* AB style only.
** Provides a positive sealing surface to eliminate potential fluid bypass in competitive housings with blunt knife edges.
*** When the M symbol is selected the part number must end in H21 code.
적용분야
영역
Reviews
Earn 10% off* your next order online by leaving a review of this product. Please login to your account to leave a review. We appreciate and value your feedback.
*Subject to Terms and Conditions.