설명
Like the Pall PCM400, the new improved PCM500 fluid cleanliness unit uses proven mesh Blockage technology to report accurate, reliable, 3 part ISO 4406 cleanliness codes for most types of fluids, in many types of environment.
With the PCM500 you can:
- Monitor contamination levels in mineral, synthetic, or water based fluids. Results are unaffected by the presence of water, air, or dark fluids
- Get accurate, 3 part* ISO 4406 cleanliness code results in under 6 minutes and quickly take preventative action
- Upload real-time results directly to mobile devices for analysis and action
- 'Pass off' cleanliness of new builds quickly and confidently
- Protect your systems from catastrophic failure by detecting abnormal fluid cleanliness conditions quickly
The PCM500 portable cleanliness monitor can also be permanently installed to monitor critical applications (including component test facilities) or used as a portable device for routine condition monitoring of various fluid systems
PCM500 Monitor Features
* 3 part code measured at 4 µm, 6 µm and 14 µm (c) per ISO 16889. |
![]() For ordering and pricing information contact your local sales office or distributor Contact Us. |
응용분야
|
![]() |
For ordering and pricing information contact your local sales office or distributor Contact Us.
규격사양
Power supply: | 90-260 VAC or integral 12 VDC Lithium Ion battery |
Battery life: | Typically 35 samples |
Temperature: | 10°C to 80°C (50°F to 176°F) |
Range: | (dependent on fluid type) |
Compatibility: | Water glycols, aqueous solutions. Petroleum and synthetic oils (hydraulic lubricating, dielectric, etc.) fuels, industrial phosphate esters. |
Seals: | Fluorocarbon |
Operating viscosity: | 1.5 to 450 cSt (30 to 2,200 SUS) |
Pressure: | 0 to 315 bar (4568 psi) max |
Monitoring Range: | ISO 4406: <11/9/7 to 23/21/17 SAE AS 4059 Table 1 Class 1 to 12 (derived from NAS 1638) SAE AS 4059 Table 2 >4 µm 1A to 12A, >6 µm 1B to 12B >14 µm 1C to 12C |
Water in Oil % RH: | ± 2% at 5 to 95% RH (PCM500W) |
Accuracy: | ± 1/2 ISO 4406 Code |
Communication Ports: | 3 x USB's (Data Acquisition, PC Setup, Printer), Ethernet and RS232C (PLC Control) |
Enclosure: | IP 65 (NEMA 4) |
Weight: | 11 kg (24 lb) |
Dimensions: | 400 x 260 x 250 mm (15.8 x 10.2 x 10 inches) |
![]() |
![]() Multiple test data can be stored and displayed for subsequent analysis and download |
종류
사용
주문정보
Table 1: Fitting Type
Table 2: Power Lead
|
![]() |
Printer Kit and Accessories
PCM500-PRTFor ordering and pricing information contact your local sales office or distributor Contact Us.
적용분야
영역
Reviews
Earn 10% off* your next order online by leaving a review of this product. Please login to your account to leave a review. We appreciate and value your feedback.
*Subject to Terms and Conditions.