Flows to 40 gpm (145 L/min)
Pressures to 600 psi (41 bar)
Port sizes: 3/4" and 1"
Please Note:
The 8110 series filter assemblies are no longer available and are being replaced with Ultipleat® UR219 Filter Assemblies
All replacement filter elements, differential pressure indicators and sealkits remain available for this series. See 'Ordering Information' tab above for details of spares.
Pressures to 600 psi (41 bar)
Port sizes: 3/4" and 1"
The 8110 series filter assemblies are no longer available and are being replaced with Ultipleat® UR219 Filter Assemblies
All replacement filter elements, differential pressure indicators and sealkits remain available for this series. See 'Ordering Information' tab above for details of spares.
Features
- Optional Differential Pressure Devices
- Gray Cast Iron Head
- Painted External Finish
- Drawn Steel Bowl
- High Strength Fatigue Rated Housing
- Full Flow Fast Response Bypass Valve
- O-Ring Seals
- Ultipor® III Element
- Optional Drain Port (Not Shown)
Maximum Acceptable Working Pressure:
600 psi (41 bar)Fatigue Pressure Rating:
600 psi (41 bar)(2,000,000 cycles to 600 psi)
Typical Burst Pressure:
2400 psi (165 bar)Temperature Range:
Nitrile seals -45°F to 225°F (-43°C to 107°C)Fluorocarbon seals -20°F to 250°F (-29°C to 120°C)
140°F (60°C) maximum in HWCF or water-glycol fluids
Dry Weights:
R length– 9 lbs. (4.1 kg)S length– 10 lbs. (4.6 kg)
T length– 11 lbs. (5 kg)
Filter Element Collapse Pressure:
9100–290 psid (20 bar)Dimensional Drawings

Element Pressure Drop Factor
Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G.Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.
9100 Series Element ![]() | |||||
Length | KZ | KP | KN | KS | KT |
---|---|---|---|---|---|
4" | 1.01 | 0.44 | 0.36 | 0.27 | 0.19 |
8" | 0.53 | 0.25 | 0.21 | 0.16 | 0.11 |
13" | 0.32 | 0.14 | 0.11 | 0.09 | 0.06 |
|
Housings, Vessels, or Assemblies
Assembly P/N: | H | | 8110 | | | | | | | |
|
| Table1 |
| Table2 | Table3 | Table4 | Table5 | Table6 | Table7 | Table8 |
Element P/N: | HC | 9100 F | | | |
|
|
|
|
|
|
| Table4 | Table5 | Table1 |
|
|
|
Note: Choose from the options in the following tables to compile the specific Product Number.
TABLE 1: SEAL OPTIONS | |
Code | Seals |
---|---|
H | Nitrile |
Z | Fluorocarbon |
TABLE 2: PORT STYLE OPTIONS | |
Code | Port Style |
---|---|
A | SAE J514 straight thread |
TABLE 3: PORT SIZE OPTIONS | |
Code | Size |
---|---|
12 | 3/4" |
16 | 1" |
TABLE 4: FILTER ELEMENT OPTIONS | ||
Code | ßx ![]() | ßx(c)=1000 |
---|---|---|
KZ | <1 | 2.5 |
KP | 3 | 5 |
KN | 6 | 7 |
KS | 12 | 12 |
KT | 25 | 22 |
TABLE 5: LENGTH OPTIONS* | |
Assembly Code | Element Code** |
---|---|
R | 4 |
S | 8 |
T | 13 |
* Use code in second column for element part no. |
TABLE 6: BYPASS VALVE OPTIONS | |
Code | Description |
---|---|
A | 25 psid ± 5 |
B | 50 psid ± 5 |
TABLE 7: DIFFERENTIAL PRESSURE DEVICE OPTIONS | |
Code | Description |
---|---|
P | Visual indicator with thermal lockout |
D | Visual indicator with no thermal lockout |
L | Electrical switch (SPDT) with 6" leads |
T | Electrical switch with DIN connector |
M | 'T' type switch with matching wiring cap |
S | Electrical switch with MS receptacle |
V | Combined visual/electrical with DIN connector |
B | Plug in place of indicator |
TABLE 8: OPTIONAL DRAIN PORTS | |
Code | Description |
---|---|
Omit | No drain |
6 | 1/4" SAE drain port and plug |
We appreciate your review of this product. Please login to your account to leave a review.