Medallion™ HP Series Liquid/Gas Coalescers

 

Pall’s Medallion™ HP line of liquid/gas coalescers is designed to meet the needs of the process industry, offering high performance and reduced operation and maintenance costs. Medallion coalescers can be used for many applications to enhance process performance.

Pall offers a full range of product options designed to meet various performance needs.

Medallion™ HP Series Liquid/Gas Coalescers

Product images are a representation of product family for illustration purposes only. Actual products may vary.

Order Products

Inlet Configuration

1-1½ in (25-38 mm) sanitary flange

Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 380 cm² EFA, 1-1½ in. sanitary flange connections, pre-sterilized by gamma irradiation product photo

Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 380 cm² EFA, 1-1½ in. sanitary flange connections, pre-sterilized by gamma irradiation

Product ID: KA1V002PV1S
Unit of Measure
1/EA
Min Order Qty
1
Membrane Material
Polyvinylidene fluoride (PVDF)
Effective Filtration Area (Metric)
380 cm²
See All Attributes
Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 380 cm² EFA, 1-1½ in. sanitary flange connections, suitable for gamma irradiation product photo

Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 380 cm² EFA, 1-1½ in. sanitary flange connections, suitable for gamma irradiation

Product ID: KA1V002PV1G
Unit of Measure
1/EA
Min Order Qty
1
Membrane Material
Polyvinylidene fluoride (PVDF)
Effective Filtration Area (Metric)
380 cm²
See All Attributes
Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 820 cm² EFA, 1-1½ in. sanitary flange connections, suitable for gamma irradiation product photo

Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 820 cm² EFA, 1-1½ in. sanitary flange connections, suitable for gamma irradiation

Product ID: KA2V002PV1G
Unit of Measure
1/EA
Min Order Qty
1
Membrane Material
Polyvinylidene fluoride (PVDF)
Effective Filtration Area (Metric)
820 cm²
See All Attributes
Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 1700 cm² EFA, 1-1½ in. sanitary flange connections, suitable for gamma irradiation product photo

Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 1700 cm² EFA, 1-1½ in. sanitary flange connections, suitable for gamma irradiation

Product ID: KA3V002PV1G
Unit of Measure
1/EA
Min Order Qty
1
Membrane Material
Polyvinylidene fluoride (PVDF)
Effective Filtration Area (Metric)
1700 cm²
See All Attributes
Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 1700 cm² EFA, 1-1½ in. sanitary flange connections, pre-sterilized by gamma irradiation product photo

Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 1700 cm² EFA, 1-1½ in. sanitary flange connections, pre-sterilized by gamma irradiation

Product ID: KA3V002PV1S
Unit of Measure
1/EA
Min Order Qty
1
Membrane Material
Polyvinylidene fluoride (PVDF)
Effective Filtration Area (Metric)
1700 cm²
See All Attributes

Emflon® PFR Membrane in Novasip™ Capsules have lower installation costs than comparable systems. Its steam sterilizing durability provides a long service life and low maintenance costs. Novasip™ filters use polyethermide because of its strong withstanding features against elevated temperature and pressure. Designed with air and vent applications Novasip™ filters can be used in a range of operating conditions.

Emflon® II Membrane in Kleenpak™ Capsules serves the user's specific systematic needs. Pall offers options including gama-irradiatable, pre-sterilized and custom-made sets. All versions perform to the same top quality standard. Each unit is fully integrity testable and has the highly retentive Emflon II membrane. These capsule filters provide high air flows of both air and gas.

9 Products In Family

Documents

Datasheet

  • Medallion™ HP Series Liquid/Gas Coalescers

    Select Language :

Description

Pall’s Medallion™ HP line of liquid/gas coalescers is designed to meet the needs of the process industry, offering high performance and reduced operation and maintenance costs. Medallion coalescers can be used for many applications to enhance process performance.

 

Pall offers a full range of product options designed to meet various performance needs.

 

Features, Advantages, and Benefits of the Pall Medallion Liquid/Gas Coalescers

 
Features Advantages Benefits
Medallion media pack
  • High liquid removal per unit area
  • Fewer elements needed
  • Minimized vessel diameter
  • Reduced need for an upstream bulk separator
  • Reduced capital and installation costs
High-capacity large-diameter element
  • Fewer elements needed for a given gas flow rate
  • Minimized vessel diameter
  • Reduced capital and installation costs
  • Smaller space required for installation
High-effective filtration area
  • Fewer element changeouts needed
  • The high solids removal efficiency
  • Lower operating and maintenance costs

High-efficiency media and equipment

  • Lower maintenance costs and availability

Applications

  • Inlet/Outlet Reciprocating Compressor
  • Turbine Protection
  • Inlet/Outlet Amine Contactor
  • Low and Ultra-low NOx Burner Protection
  • Inlet/Outlet Glycol Contactor
  • Gas Separation Membrane Protection
  • Mole Sieve Protection
  • Sales Gas
  • Mercury Removal Catalyst Protection
  • Transmission Pipeline Gas
  • Pipeline Metering / Compression Stations

Specifications

Materials of construction

Glass Microfiber Medium
A Style Compatible with most applications
  SOE P/N CS604LGT2H13
  DOE P/N CS604LGT2DH13
B Style Compatible with Amine and Ammonia gas
  SOE P/N CS604LGBT2H13
  DOE P/N CS604LGBT2DH13
End caps 300 series SS

Performance

Data

Liquids
  • 99.999% at 0.3 micron per DOP test
  • 1 ppb downstream liquids (CAGI)1
Solids  99.7% for particles >0.3 micron per NaCl test
Max Burst Pressure  50 psid (3.45 bard) 
Maximum operating temperatures
  • 180°F (82.2 °C) in gas service with no water present
  • 140°F (60.0 °C) in gas service with water present

 

1 Per the modified ANSI/CAGI-400-1999 test procedure

Type

Coalescers

Additional Information