Activated Carbon Filter Sheets

For color and flavor

Seitz® Activated Carbon Filter Sheets were developed to satisfy general purpose carbon adsorption applications in the food and beverage industry. Why activated carbon sheets? The sheet media incorporate activated carbon within a matrix of cellulosic fibers, which can be coupled with a protective filter paper to prevent carbon particle shedding downstream of the filter. Additionally, the Seitz immobilized carbon filter media's adsorption efficiency is greater than an equivalent amount of bulk powdered activated carbon (PAC), reducing overall process time and increasing product yield. An internal comparative study using the same carbon grade showed up to 150% better color removal efficiency than bulk PAC.

Order Products

Removal Rating

0.2 µm

Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 380 cm² EFA, 1-1½ in. sanitary flange connections, pre-sterilized by gamma irradiation product photo

Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 380 cm² EFA, 1-1½ in. sanitary flange connections, pre-sterilized by gamma irradiation

Product ID: KA1V002PV1S
Unit of Measure
1/EA
Min Order Qty
1
Membrane Material
Polyvinylidene fluoride (PVDF)
Effective Filtration Area (Metric)
380 cm²
See All Attributes
Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 380 cm² EFA, 1-1½ in. sanitary flange connections, suitable for gamma irradiation product photo

Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 380 cm² EFA, 1-1½ in. sanitary flange connections, suitable for gamma irradiation

Product ID: KA1V002PV1G
Unit of Measure
1/EA
Min Order Qty
1
Membrane Material
Polyvinylidene fluoride (PVDF)
Effective Filtration Area (Metric)
380 cm²
See All Attributes
Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 820 cm² EFA, ¼-½ in. hose barb connections, pre-sterilized by gamma irradiation product photo

Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 820 cm² EFA, ¼-½ in. hose barb connections, pre-sterilized by gamma irradiation

Product ID: KA2V002PV2S
Unit of Measure
1/EA
Min Order Qty
1
Membrane Material
Polyvinylidene fluoride (PVDF)
Effective Filtration Area (Metric)
820 cm²
See All Attributes

This product is currently not available. Please contact us for more information.

Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 820 cm² EFA, ¼-½ in. hose barb connections, suitable for gamma irradiation product photo

Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 820 cm² EFA, ¼-½ in. hose barb connections, suitable for gamma irradiation

Product ID: KA2V002PV2G
Unit of Measure
1/EA
Min Order Qty
1
Membrane Material
Polyvinylidene fluoride (PVDF)
Effective Filtration Area (Metric)
820 cm²
See All Attributes
Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 820 cm² EFA, 1-1½ in. sanitary flange connections, suitable for gamma irradiation product photo

Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 820 cm² EFA, 1-1½ in. sanitary flange connections, suitable for gamma irradiation

Product ID: KA2V002PV1G
Unit of Measure
1/EA
Min Order Qty
1
Membrane Material
Polyvinylidene fluoride (PVDF)
Effective Filtration Area (Metric)
820 cm²
See All Attributes
Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 1700 cm² EFA, ½ in. hose barb connections, pre-sterilized by gamma irradiation product photo

Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 1700 cm² EFA, ½ in. hose barb connections, pre-sterilized by gamma irradiation

Product ID: KA3V002PV6S
Unit of Measure
1/EA
Min Order Qty
1
Membrane Material
Polyvinylidene fluoride (PVDF)
Effective Filtration Area (Metric)
1700 cm²
See All Attributes

This product is currently not available. Please contact us for more information.

Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 1700 cm² EFA, ½ in. hose barb connections, suitable for gamma irradiation product photo

Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 1700 cm² EFA, ½ in. hose barb connections, suitable for gamma irradiation

Product ID: KA3V002PV6G
Unit of Measure
1/EA
Min Order Qty
1
Membrane Material
Polyvinylidene fluoride (PVDF)
Effective Filtration Area (Metric)
1700 cm²
See All Attributes
Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 1700 cm² EFA, 1-1½ in. sanitary flange connections, pre-sterilized by gamma irradiation product photo

Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 1700 cm² EFA, 1-1½ in. sanitary flange connections, pre-sterilized by gamma irradiation

Product ID: KA3V002PV1S
Unit of Measure
1/EA
Min Order Qty
1
Membrane Material
Polyvinylidene fluoride (PVDF)
Effective Filtration Area (Metric)
1700 cm²
See All Attributes
Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 1700 cm² EFA, 1-1½ in. sanitary flange connections, suitable for gamma irradiation product photo

Emflon® II membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 1700 cm² EFA, 1-1½ in. sanitary flange connections, suitable for gamma irradiation

Product ID: KA3V002PV1G
Unit of Measure
1/EA
Min Order Qty
1
Membrane Material
Polyvinylidene fluoride (PVDF)
Effective Filtration Area (Metric)
1700 cm²
See All Attributes

Emflon® PFRW Kleenpak™ Capsules, KA2PFRW1

Product ID: KA2PFRW1
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
0.2 µm
Aerosol Bacteriophage Retention
Excellent
Cage, Core, Fin End and Endcap
Polypropylene
Capsule Length (Metric mm)
158 mm
Cumulative Autoclave Steaming
50 hrs @ 140 °C
Filter Media
Double Layer PTFE
See All Attributes

Emflon® PFRW Kleenpak™ Capsules, KA3PFRW1

Product ID: KA3PFRW1
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
0.2 µm
Aerosol Bacteriophage Retention
Excellent
Cage, Core, Fin End and Endcap
Polypropylene
Capsule Length (Metric mm)
174 mm
Cumulative Autoclave Steaming
50 hrs @ 140 °C
Filter Media
Double Layer PTFE
See All Attributes

Emflon® PFR Membrane in Novasip™ Capsules have lower installation costs than comparable systems. Its steam sterilizing durability provides a long service life and low maintenance costs. Novasip™ filters use polyethermide because of its strong withstanding features against elevated temperature and pressure. Designed with air and vent applications Novasip™ filters can be used in a range of operating conditions.

Document

Instructions for Use

  • Seitz Sheets: Instructions

    Select Language :

Applications

Seitz AKS4 Sheets:

  • Correction of off-color, flavor and odors in distilled spirits
  • Decolorization of sweetener and sugar syrups 
  • Color correction in juice and beer applications
  • Gelatin decolorization and deodorization