Seitz® IR Series Depth Filter Sheets

Reduce your risk of precipitation in distilled spirits

Seitz Ion Reduced (IR) Depth Filter Sheets are part of the IR series of products. These media undergo a proprietary treatment that results in extremely low extractable ions, making them the ideal solution for distilled spirit applications. The homogenous and consistent media include surface, depth and adsorptive filtration for high solids retention, which gives you high solids retention, very good permeability and excellent filtrate quality. Available in multiple grades. 

  • High economic efficiency due to a long service life
  • Each individual filter sheet is laser etched with the sheet grade, batch number and production date for full traceability

Order Products

Brand

PhaseSep®

LCMEH

Product ID: LCMEH
Unit of Measure
1/EA
Min Order Qty
1

PhaseSep L/L Coalescer, 20in length, 3.75in diameter, ≤15ppm separation level

Product ID: LCS2H1AH316
Unit of Measure
1/EA
Min Order Qty
1
Coalescer Length (Imperial)
20 in
Coalescer Length (Metric)
50.8 cm

PhaseSep L/L Coalescer, 6in length, 2.75in diameter, ≤15ppm separation level

Product ID: LCS06H1HH
Unit of Measure
1/EA
Min Order Qty
1
Maximum Operating Temperature (F)
300 °F
Maximum Operating Temperature (C)
149 °C
Change out pressure drop (bar)
1.03 bar
Change out pressure drop (psid)
15 psid
Maximum differential pressure rating (bar)
3.5 bar
Maximum differential pressure rating (psid)
50 psid
See All Attributes

PhaseSep EL L/L Coalescer, 20in length, 3.75in diameter, ≤15ppm separation level

Product ID: LCS2ELPH
Unit of Measure
1/EA
Min Order Qty
1
Maximum Operating Temperature (F)
300 °F
Maximum Operating Temperature (C)
149 °C
Change out pressure drop (bar)
1.03 bar
Change out pressure drop (psid)
15 psid
Maximum differential pressure rating (bar)
3.5 bar
Maximum differential pressure rating (psid)
50 psid
See All Attributes

PhaseSep L/L Coalescer, 20in length, 3.75in diameter, ≤15ppm separation level

Product ID: LCS2H2HH
Unit of Measure
1/EA
Min Order Qty
1
Maximum Operating Temperature (F)
300 °F
Maximum Operating Temperature (C)
149 °C
Change out pressure drop (bar)
1.03 bar
Change out pressure drop (psid)
15 psid
Maximum differential pressure rating (bar)
3.5 bar
Maximum differential pressure rating (psid)
50 psid
See All Attributes

PhaseSep L/L Coalescer, 20in length, 3.75in diameter, ≤15ppm separation level, 14µm Beta 5000 solids removal rating

Product ID: LCS2H1AH1
Unit of Measure
1/EA
Min Order Qty
1
Maximum Operating Temperature (F)
300 °F
Maximum Operating Temperature (C)
149 °C
Change out pressure drop (bar)
1.03 bar
Change out pressure drop (psid)
15 psid
Maximum differential pressure rating (bar)
3.5 bar
Maximum differential pressure rating (psid)
50 psid
See All Attributes

PhaseSep AS L/L Coalescer - PPS Depth - 20" - Fine Removal Rating

Product ID: LCS2FPS100966
Unit of Measure
12/EA
Min Order Qty
12
Coalescer Length (Imperial)
20 in
Coalescer Length (Metric)
50.8 cm

This product is currently not available. Please contact us for more information.

PhaseSep L/L Coalescer, 20in length, 3.75in diameter, ≤15ppm separation level

Product ID: LCS2H2HH1
Unit of Measure
4/EA
Min Order Qty
4
Maximum Operating Temperature (F)
300 °F
Maximum Operating Temperature (C)
149 °C
Change out pressure drop (bar)
1.03 bar
Change out pressure drop (psid)
15 psid
Maximum differential pressure rating (bar)
3.5 bar
Maximum differential pressure rating (psid)
50 psid
See All Attributes
PhaseSep EL - LCS4ELPHCV product photo

PhaseSep EL L/L Coalescer, 40in length, 3.75in diameter, ≤15ppm separation level

Product ID: LCS4ELPHCV
Unit of Measure
1/EA
Min Order Qty
1

PhaseSep L/L Coalescer, 40in length, 3.75in diameter, ≤15ppm separation level

Product ID: LCS4H1AH11
Unit of Measure
1/EA
Min Order Qty
1
Maximum Operating Temperature (F)
300 °F
Maximum Operating Temperature (C)
149 °C
Change out pressure drop (bar)
1.03 bar
Change out pressure drop (psid)
15 psid
Maximum differential pressure rating (bar)
3.5 bar
Maximum differential pressure rating (psid)
50 psid
See All Attributes

PhaseSep AS L/L Coalescer - PPS Depth - 40" - Medium Removal Rating

Product ID: LCS4FPS200966
Unit of Measure
12/EA
Min Order Qty
12
Maximum Operating Temperature (F)
250 °F
Maximum Operating Temperature (C)
121 °C
Change out pressure drop (bar)
1.03 bar
Change out pressure drop (psid)
15 psid
Maximum differential pressure rating (bar)
2.07 bar
Maximum differential pressure rating (psid)
30 psid
See All Attributes

This product is currently not available. Please contact us for more information.

PhaseSep L/L Coalescer, 40in length, 3.75in diameter, ≤15ppm separation level

Product ID: LCS4H2HH11
Unit of Measure
1/EA
Min Order Qty
1
Maximum Operating Temperature (F)
300 °F
Maximum Operating Temperature (C)
149 °C
Change out pressure drop (bar)
1.03 bar
Change out pressure drop (psid)
15 psid
Maximum differential pressure rating (bar)
3.5 bar
Maximum differential pressure rating (psid)
50 psid
See All Attributes

This product is currently not available. Please contact us for more information.

Documents

Datasheet

  • Seitz IR Series Depth Filter Sheets

    Select Language :

Instructions for Use

  • Seitz Sheets: Instructions

    Select Language :

Applications

  • Seitz KS 50 IR 

Polishing filtration in white spirits

 

  • Seitz K 100 IR

Chill filtration of white spirits

 

  • Seitz K 250 IR 

Chill filtration of tannin-containing spirits or white spirits high in fatty acids

 

  • Seitz K 800 IR 

Particle removal

Specifications

Relative Retention Rating1

Food Contact Compliance

  • Food contact compliant filters are available. Please consult the Declarations of Compliance for applicable part numbers at the links below.
  • Please refer to the Pall website for a Declaration of Compliance to specific National Legislation and/or Regional Regulatory requirements for food contact use.

 

Main Constituents

Cellulose, diatomaceous earth (DE, Kieselguhr), perlite

 

Characterization

Grade Mass per Unit
Area g/m2
Thickness
mm
Ash
%
Water Permeability2
L/m2/min
(gal/ft2/min)
KS 50 IR 1350 3.7 46 93 (2.3)
K 100 IR 1400 4.3 51 187 (4.6)
K 250 IR 1250 4 46 510 (12.5)
K 800 IR 1250 4.1 46 1275 (31.4)

These figures have been determined in accordance with in-house test methods and the methods of the Technical / Analytical Work Group within the European Depth Filtration Association.

 

2The permeability was measured under test conditions with clean water at 20° C (68° F) and a Δp of 1 bar (14.5 psi).

 

The diagram below illustrates the release of calcium and magnesium from the comparable standard filter sheet K100 and K100 IR into whisky during filtration.

The following total calcium and magnesium release per m2 filter sheet at a flow velocity of 500 L/m2/h (12.3 gal/ft2/h) was calculated during this filtration run:

Sheet Calcium mg/m2 (%) Magnesium mg/m2(%)
K 1003 667 (100) 192 (100
K 100 IR 146 (22) 68 (35)

3The K 100 is the comparable standard sheet to the K 100 IR with regard to the material composition.

 

Quality

  • Filter sheets produced in a controlled environment
  • Manufactured according to ISO 9001:2015 certified Quality Management System

 

The use of ion-reduced water (deionized water) is highly recommended for the reconstitution of distillates to single strength.

 

To prevent dilution upon installation, a water rinse is not recommended for sheet filters used in the spirits industry. Product circulation for 10 to 15 minutes back to the feed tank helps distribute ions extracted at the beginning of filtration to the entire batch, reducing precipitation's overall risk.

 

Filtration Guidelines4

As the filtrate quality can be impacted by the filtration flow rate, the following table provides flux rate guidelines.

Application Flow Velocity L/m2/h (gph/ft2)
Particle filtration of brown spirits 500 – 700 (12.3 – 17.2)
Particle filtration white spirits 700 – 900 (17.2 – 22.1)
Chill filtration of brown spirits and white spirits high in fatty acids 250 – 400 (6.1 – 9.8)
Chill filtration of white spirits 400 – 600 (9.8 – 14.7)

4 Please contact Pall for recommendations on your specific filtration process as results may vary by product, pre-filtration and filtration conditions.

 

For additional operating guidelines, please refer to the instructions provided by Pall.