Seitz® IR Series Depth Filter Sheets

Reduce your risk of precipitation in distilled spirits

Seitz Ion Reduced (IR) Depth Filter Sheets are part of the IR series of products. These media undergo a proprietary treatment that results in extremely low extractable ions, making them the ideal solution for distilled spirit applications. The homogenous and consistent media include surface, depth and adsorptive filtration for high solids retention, which gives you high solids retention, very good permeability and excellent filtrate quality. Available in multiple grades. 

  • High economic efficiency due to a long service life
  • Each individual filter sheet is laser etched with the sheet grade, batch number and production date for full traceability

Order Products

Cartridge Length (Imperial)

9.75 in

Nexis® A Series Filter Cartridges, Removal Rating 0.5 μm, Polypropylene, Length 9.75 inches, Expanded PTFE gaskets FEP encapsulated silicone Orings

Product ID: NXA05975UDOET
Unit of Measure
30/EA
Min Order Qty
30
Removal Rating
0.5 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
9.75 in
Cartridge Length (Metric)
248 mm
Cartridge Length (Metric)
24.8 cm
Gasket / O-Ring Material
Expanded PTFE (gaskets) FEP encapsulated silicone (O-rings)
See All Attributes

Nexis® A Series Filter Cartridges, Removal Rating 10 μm, Polypropylene, Length 9.75 inches

Product ID: NXA10975U
Unit of Measure
30/EA
Min Order Qty
30
Removal Rating
10 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
9.75 in
Cartridge Length (Metric)
248 mm
Cartridge Length (Metric)
24.8 cm
Gasket / O-Ring Material
NA
See All Attributes

Nexis® A Series Filter Cartridges, Removal Rating 1 μm, Polypropylene, Length 9.75 inches

Product ID: NXA1975U
Unit of Measure
30/EA
Min Order Qty
30
Removal Rating
1 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
9.75 in
Cartridge Length (Metric)
248 mm
Cartridge Length (Metric)
24.8 cm
Gasket / O-Ring Material
NA
See All Attributes

Nexis® A Series Filter Cartridges, Removal Rating 20 μm, Polypropylene, Length 9.75 inches, DOE industrial (no end caps)

Product ID: NXA20975U
Unit of Measure
60/EA
Min Order Qty
60
Removal Rating
20 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
9.75 in
Cartridge Length (Metric)
248 mm
Cartridge Length (Metric)
24.8 cm
Gasket / O-Ring Material
NA
See All Attributes

Nexis® A Series Filter Cartridges, Removal Rating 3 μm, Polypropylene, Length 9.75 inches

Product ID: NXA3975U
Unit of Measure
30/EA
Min Order Qty
30
Removal Rating
3 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
9.75 in
Cartridge Length (Metric)
248 mm
Cartridge Length (Metric)
24.8 cm
Gasket / O-Ring Material
NA
See All Attributes

Nexis® T Filter Cartridges, Removal Rating 100 μm, Polypropylene, Length 9.75 inches

Product ID: NXT100975U
Unit of Measure
30/EA
Min Order Qty
30
Removal Rating
100 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
9.75 in
Cartridge Length (Metric)
248 mm
Cartridge Length (Metric)
24.8 cm
Gasket / O-Ring Material
NA
See All Attributes

Nexis® T Filter Cartridges, Removal Rating 10 μm, Polypropylene, Length 9.75 inches

Product ID: NXT10975U
Unit of Measure
30/EA
Min Order Qty
30
Removal Rating
10 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
9.75 in
Cartridge Length (Metric)
248 mm
Cartridge Length (Metric)
24.8 cm
Gasket / O-Ring Material
NA
See All Attributes

Nexis® T Filter Cartridges, Removal Rating 10 μm, Polypropylene, Length 9.75 inches, DOE industrial (no end caps)

Product ID: NXT10975U729
Unit of Measure
30/EA
Min Order Qty
30
Removal Rating
10 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
9.75 in
Cartridge Length (Metric)
248 mm
Cartridge Length (Metric)
24.8 cm
Gasket / O-Ring Material
NA
See All Attributes

Nexis® T Filter Cartridges, Removal Rating 120 μm, Polypropylene, Length 9.75 inches, DOE industrial (no end caps)

Product ID: NXT120975U729
Unit of Measure
30/EA
Min Order Qty
30
Removal Rating
120 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
9.75 in
Cartridge Length (Metric)
248 mm
Cartridge Length (Metric)
24.8 cm
Gasket / O-Ring Material
NA
See All Attributes

Nexis® T Filter Cartridges, Removal Rating 120 μm, Polypropylene, Length 9.75 inches

Product ID: NXT120975U
Unit of Measure
30/EA
Min Order Qty
30
Removal Rating
120 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
9.75 in
Cartridge Length (Metric)
248 mm
Cartridge Length (Metric)
24.8 cm
Gasket / O-Ring Material
NA
See All Attributes

Nexis® T Filter Cartridges, Removal Rating 150 μm, Polypropylene, Length 9.75 inches

Product ID: NXT150975U
Unit of Measure
30/EA
Min Order Qty
30
Removal Rating
150 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
9.75 in
Cartridge Length (Metric)
248 mm
Cartridge Length (Metric)
24.8 cm
Gasket / O-Ring Material
NA
See All Attributes
NXT 150-9.75U-H21 product photo

Nexis, NXT, 150 μm, 24.8 cm (9.75 in), DOE, Santoprene gasket seal

Product ID: NXT150975UH21
Unit of Measure
1/EA
Min Order Qty
1
Micron
150 micron

Documents

Datasheet

  • Seitz IR Series Depth Filter Sheets

    Select Language :

Instructions for Use

  • Seitz Sheets: Instructions

    Select Language :

Applications

  • Seitz KS 50 IR 

Polishing filtration in white spirits

 

  • Seitz K 100 IR

Chill filtration of white spirits

 

  • Seitz K 250 IR 

Chill filtration of tannin-containing spirits or white spirits high in fatty acids

 

  • Seitz K 800 IR 

Particle removal

Specifications

Relative Retention Rating1

Food Contact Compliance

  • Food contact compliant filters are available. Please consult the Declarations of Compliance for applicable part numbers at the links below.
  • Please refer to the Pall website for a Declaration of Compliance to specific National Legislation and/or Regional Regulatory requirements for food contact use.

 

Main Constituents

Cellulose, diatomaceous earth (DE, Kieselguhr), perlite

 

Characterization

Grade Mass per Unit
Area g/m2
Thickness
mm
Ash
%
Water Permeability2
L/m2/min
(gal/ft2/min)
KS 50 IR 1350 3.7 46 93 (2.3)
K 100 IR 1400 4.3 51 187 (4.6)
K 250 IR 1250 4 46 510 (12.5)
K 800 IR 1250 4.1 46 1275 (31.4)

These figures have been determined in accordance with in-house test methods and the methods of the Technical / Analytical Work Group within the European Depth Filtration Association.

 

2The permeability was measured under test conditions with clean water at 20° C (68° F) and a Δp of 1 bar (14.5 psi).

 

The diagram below illustrates the release of calcium and magnesium from the comparable standard filter sheet K100 and K100 IR into whisky during filtration.

The following total calcium and magnesium release per m2 filter sheet at a flow velocity of 500 L/m2/h (12.3 gal/ft2/h) was calculated during this filtration run:

Sheet Calcium mg/m2 (%) Magnesium mg/m2(%)
K 1003 667 (100) 192 (100
K 100 IR 146 (22) 68 (35)

3The K 100 is the comparable standard sheet to the K 100 IR with regard to the material composition.

 

Quality

  • Filter sheets produced in a controlled environment
  • Manufactured according to ISO 9001:2015 certified Quality Management System

 

The use of ion-reduced water (deionized water) is highly recommended for the reconstitution of distillates to single strength.

 

To prevent dilution upon installation, a water rinse is not recommended for sheet filters used in the spirits industry. Product circulation for 10 to 15 minutes back to the feed tank helps distribute ions extracted at the beginning of filtration to the entire batch, reducing precipitation's overall risk.

 

Filtration Guidelines4

As the filtrate quality can be impacted by the filtration flow rate, the following table provides flux rate guidelines.

Application Flow Velocity L/m2/h (gph/ft2)
Particle filtration of brown spirits 500 – 700 (12.3 – 17.2)
Particle filtration white spirits 700 – 900 (17.2 – 22.1)
Chill filtration of brown spirits and white spirits high in fatty acids 250 – 400 (6.1 – 9.8)
Chill filtration of white spirits 400 – 600 (9.8 – 14.7)

4 Please contact Pall for recommendations on your specific filtration process as results may vary by product, pre-filtration and filtration conditions.

 

For additional operating guidelines, please refer to the instructions provided by Pall.