Seitz® PERMAdur® S Support Sheets

Ideal for high performance and longevity 

The Seitz Permadur S Support Sheets afford stable, reusable precoat filtration in plate and frame presses. After filtration, the plate and frame are opened. The filter cake is removed, leaving the Seitz PERMAdur S filter sheet ready for the next run. Made of high-quality cellulose and polyolefin fibers, Seitz PERMAdur S support sheets' production is based on the latest technological and scientific achievements in-depth filter media. Get the support sheets with up to 30 percent longer service life over conventional sheets.  

  • Reduced appearance of swelling in the DE filter during filtration
  • May be removed from the filter intact without risk of damage or tearing
  • Retention of wet strength even with repeated hot sanitizations
  • Full traceability - Each individual filter sheet is laser etched with the sheet grade, batch number and production date. The packing label includes sheet grade, batch, identification number and a fork and glass symbol.
Seitz PERMAdur S Support Sheets

Product images are a representation of product family for illustration purposes only. Actual products may vary.

Order Products

Product Type

Service Spare Parts

Document Package product photo

Document Package

Product ID: PPD006H
Unit of Measure
1/EA
Min Order Qty
1
S1208105 product photo

1208105

Product ID: S1208105
Unit of Measure
1/EA
Min Order Qty
1
S1210006 product photo

ROTEX38 coupling 132Motor 50 80pump blac

Product ID: S1210006
Unit of Measure
50/EA
Min Order Qty
50
ORING LMO C/N BUNA N product photo

ORING LMO C/N BUNA N

Product ID: T10505030
Unit of Measure
1/EA
Min Order Qty
1
ORING LMO SHL TEFLON product photo

ORING LMO SHL TEFLON

Product ID: T10520031
Unit of Measure
1/EA
Min Order Qty
1
AIP-0013D product photo

AIP-0013D

Product ID: P2049953
Unit of Measure
1/EA
Min Order Qty
1
UMP-053 product photo

UMP-053

Product ID: P2120215
Unit of Measure
1/EA
Min Order Qty
1
Additional membrane holder diam 47+grid product photo

Additional membrane holder diam 47+grid

Product ID: PCC0011H
Unit of Measure
1/EA
Min Order Qty
1
PCC0023D-1 product photo

Stainless steel grid 630x510mm PCC61

Product ID: PCC0023D-1
Unit of Measure
1/EA
Min Order Qty
1
SPRING COMP 316 product photo

SPRING COMP 316

Product ID: T10718030
Unit of Measure
1/EA
Min Order Qty
1
TIE ROD 3DECK ELECPOL product photo

TIE ROD 3DECK ELECPOL

Product ID: T10910132
Unit of Measure
1/EA
Min Order Qty
1
PALL TIE ROD 316 SS 41.24IN product photo

PALL TIE ROD 316 SS 41.24IN

Product ID: T11080033
Unit of Measure
1/EA
Min Order Qty
1

Documents

Datasheet

  • PERMAdur S Support Filter Sheets

    Select Language :

Instructions for Use

  • Seitz Sheets: Instructions

    Select Language :

Specifications

Food Contact Compliance 

  • Please refer to the Pall website for a Declaration of Compliance to specific National Legislation and/or Regional Regulatory requirements for food contact use.

 

Materials of Construction

  • Main components: Celluloses, Polyolefin fibers
  • Components <3%: Resin

 

Characterization:

  • Mass per unit area g/m2 - 855
  • Thickness mm – 3.5
  • Ash %  < 1
  • Heavy metals* (ppm) < 50
  • Permeability L/m2/min at 1 bar 4370

 

These figures have been determined in accordance with in-house test methods and the methods of the Technical / Analytical Work Group within the European Depth Filtration Association. *According to recommendation XXXVI/1 of the BgW.

 

  • Exctractable ions soluble in 5% acetic acid mg/m2
  • CA 800
  • Fe 5
  • Al 15

 

Quality

Filter sheets produced in a controlled environment. Manufactured according to ISO 9001:2015 certified Quality Management System.

 

Suggested Operating Instructions

Handling during installation 

  1. Place sheet over support plate of the plate and frame filter
  2. For filters with manual tightening device: moisten filter sheets then tighten
  3. For filters with hydraulic tightening device: tighten up to filter pre-pressure of 30-35 bar (432-507 psi). Rinse the filter with warm water at ambient temperature in a forward flow direction with at a flow of at least 50 L/m2
  4. Control and adjust the filter to a pre-pressure of 30-35 bar (432-507 psi) and sterilize

 

Rinsing post filtration 

  1. Flush with water at a temperature of 50-55 °C (122-131 °F)
  2. Flow in the forward direction: should be at least nominal filter output
  3. Counter pressure of 0.5 bar (7.25 psi)
  4. Duration: 10-15 minutes or until the rinse water is clear.

 

Hot water flushing 

  1. Water temperature: >85 °C (185 °F)
  2. Flow in the forward direction: minimal nominal filter output
  3. Counter pressure of 0.5 bar (7.25 psi)
  4. Duration: until a temperature of at least 85 °C (185 °F) is achieved on the outlet side. Allow the filter to stand for at least 30 minutes with hot water. Open the vent valve on the filter inlet side.

 

Steaming 

  1. Steam temperature: max 121 °C (250 °F), low-pressure steam
  2. Duration: 20 minutes