Seitz® PERMAdur® S Support Sheets

Ideal for high performance and longevity 

The Seitz Permadur S Support Sheets afford stable, reusable precoat filtration in plate and frame presses. After filtration, the plate and frame are opened. The filter cake is removed, leaving the Seitz PERMAdur S filter sheet ready for the next run. Made of high-quality cellulose and polyolefin fibers, Seitz PERMAdur S support sheets' production is based on the latest technological and scientific achievements in-depth filter media. Get the support sheets with up to 30 percent longer service life over conventional sheets.  

  • Reduced appearance of swelling in the DE filter during filtration
  • May be removed from the filter intact without risk of damage or tearing
  • Retention of wet strength even with repeated hot sanitizations
  • Full traceability - Each individual filter sheet is laser etched with the sheet grade, batch number and production date. The packing label includes sheet grade, batch, identification number and a fork and glass symbol.
Seitz PERMAdur S Support Sheets

Product images are a representation of product family for illustration purposes only. Actual products may vary.

Order Products

Featured product

false

Filter Removal Rating

22 µm

Seal Material

Fluorocarbon

UE209AT03Z

Product ID: UE209AT03Z
Unit of Measure
6/EA
Min Order Qty
6
Anti-Static
Yes
Beta Rating
BETA 2000
Element Series
UE209
Family
Athalon
Filter Media
Glass Fiber
Filter Removal Rating
22 micron, Beta 2000
See All Attributes

Athalon Glass Fiber 22 micron (Beta 2000) Fluorocarbon 8in 20.32cm

Product ID: UE210AT08Z
Unit of Measure
6/EA
Min Order Qty
6
Anti-Static
Yes
Beta Rating
BETA 2000
Element Series
UE210
Family
Athalon
Filter Media
Glass Fiber
Filter Removal Rating
22 micron, Beta 2000
See All Attributes

ELEMENT UE310AT13Z

Product ID: UE310AT13Z
Unit of Measure
6/EA
Min Order Qty
6
Anti-Static
Yes
Beta Rating
BETA 2000
Element Series
UE310
Family
Athalon
Filter Media
Glass Fiber
Filter Removal Rating
22 micron, Beta 2000
See All Attributes

Red1000 Glass Fiber 25 micron (Beta 1000) Fluorocarbon 13in 33.02cm (REPLACED BY HC2237FHT13Z)

Product ID: HC2237FDT13Z
Unit of Measure
1/EA
Min Order Qty
1
Anti-Static
No
Beta Rating
BETA 1000
Element Series
HC2237
Family
Red1000
Filter Media
Glass Fiber
Filter Removal Rating
22 micron, Beta 1000
See All Attributes

This product is currently not available. Please contact us for more information.

Red1000 Glass Fiber 22 micron (Beta 1000) Fluorocarbon 18in 45.72cm (REPLACED BY HC2296FRT18Z50)

Product ID: HC2296FKT18Z50
Unit of Measure
1/EA
Min Order Qty
1
Anti-Static
No
Beta Rating
BETA 1000
Element Series
HC2296
Family
Red1000
Filter Media
Glass Fiber
Filter Removal Rating
22 micron, Beta 1000
See All Attributes

Red1000 Glass Fiber 22 micron (Beta 1000) Fluorocarbon 36in 91.44cm (REPLACED BY HC0101FRT36ZY514)

Product ID: HC0101FKT36ZY514
Unit of Measure
1/EA
Min Order Qty
1
Anti-Static
No
Beta Rating
BETA 1000
Element Series
HC0101
Family
Red1000
Filter Media
Glass Fiber
Filter Removal Rating
22 micron, Beta 1000
See All Attributes

HC2246FCT6Z50 ELEMENT

Product ID: HC2246FCT6Z50
Unit of Measure
1/EA
Min Order Qty
1
Anti-Static
No
Beta Rating
BETA 1000
Element Series
HC2246
Family
Red1000
Filter Media
Glass Fiber
Filter Removal Rating
22 micron, Beta 1000
See All Attributes

Red1000 Glass Fiber 22 micron (Beta 1000) Fluorocarbon 19in 48.26cm (REPLACED BY HC2252FRT19Z)

Product ID: HC2252FKT19Z
Unit of Measure
1/EA
Min Order Qty
1
Anti-Static
No
Beta Rating
BETA 1000
Element Series
HC2252
Family
Red1000
Filter Media
Glass Fiber
Filter Removal Rating
22 micron, Beta 1000
See All Attributes

Red1000 Glass Fiber 22 micron (Beta 1000) Fluorocarbon 14in 35.56cm (REPLACED BY HC2296FRT14Z50)

Product ID: HC2296FKT14Z50
Unit of Measure
1/EA
Min Order Qty
1
Anti-Static
No
Beta Rating
BETA 1000
Element Series
HC2296
Family
Red1000
Filter Media
Glass Fiber
Filter Removal Rating
22 micron, Beta 1000
See All Attributes

HC2618FCT36Z ELEMENT

Product ID: HC2618FCT36Z
Unit of Measure
1/EA
Min Order Qty
1
Anti-Static
No
Beta Rating
BETA 1000
Element Series
HC2618
Family
Red1000
Filter Media
Glass Fiber
Filter Removal Rating
22 micron, Beta 1000
See All Attributes

Red1000 Anti-Static Glass Fiber 22 micron (Beta 1000) Fluorocarbon 18in 45.72cm length

Product ID: HC2618FMT18Z
Unit of Measure
1/EA
Min Order Qty
1
Anti-Static
Yes
Beta Rating
BETA 1000
Element Series
HC2618
Family
Red1000
Filter Media
Glass Fiber
Filter Removal Rating
22 micron, Beta 1000
See All Attributes

Documents

Datasheet

  • PERMAdur S Support Filter Sheets

    Select Language :

Instructions for Use

  • Seitz Sheets: Instructions

    Select Language :

Specifications

Food Contact Compliance 

  • Please refer to the Pall website for a Declaration of Compliance to specific National Legislation and/or Regional Regulatory requirements for food contact use.

 

Materials of Construction

  • Main components: Celluloses, Polyolefin fibers
  • Components <3%: Resin

 

Characterization:

  • Mass per unit area g/m2 - 855
  • Thickness mm – 3.5
  • Ash %  < 1
  • Heavy metals* (ppm) < 50
  • Permeability L/m2/min at 1 bar 4370

 

These figures have been determined in accordance with in-house test methods and the methods of the Technical / Analytical Work Group within the European Depth Filtration Association. *According to recommendation XXXVI/1 of the BgW.

 

  • Exctractable ions soluble in 5% acetic acid mg/m2
  • CA 800
  • Fe 5
  • Al 15

 

Quality

Filter sheets produced in a controlled environment. Manufactured according to ISO 9001:2015 certified Quality Management System.

 

Suggested Operating Instructions

Handling during installation 

  1. Place sheet over support plate of the plate and frame filter
  2. For filters with manual tightening device: moisten filter sheets then tighten
  3. For filters with hydraulic tightening device: tighten up to filter pre-pressure of 30-35 bar (432-507 psi). Rinse the filter with warm water at ambient temperature in a forward flow direction with at a flow of at least 50 L/m2
  4. Control and adjust the filter to a pre-pressure of 30-35 bar (432-507 psi) and sterilize

 

Rinsing post filtration 

  1. Flush with water at a temperature of 50-55 °C (122-131 °F)
  2. Flow in the forward direction: should be at least nominal filter output
  3. Counter pressure of 0.5 bar (7.25 psi)
  4. Duration: 10-15 minutes or until the rinse water is clear.

 

Hot water flushing 

  1. Water temperature: >85 °C (185 °F)
  2. Flow in the forward direction: minimal nominal filter output
  3. Counter pressure of 0.5 bar (7.25 psi)
  4. Duration: until a temperature of at least 85 °C (185 °F) is achieved on the outlet side. Allow the filter to stand for at least 30 minutes with hot water. Open the vent valve on the filter inlet side.

 

Steaming 

  1. Steam temperature: max 121 °C (250 °F), low-pressure steam
  2. Duration: 20 minutes