Seitz® PERMAdur® S Support Sheets

Ideal for high performance and longevity 

The Seitz Permadur S Support Sheets afford stable, reusable precoat filtration in plate and frame presses. After filtration, the plate and frame are opened. The filter cake is removed, leaving the Seitz PERMAdur S filter sheet ready for the next run. Made of high-quality cellulose and polyolefin fibers, Seitz PERMAdur S support sheets' production is based on the latest technological and scientific achievements in-depth filter media. Get the support sheets with up to 30 percent longer service life over conventional sheets.  

  • Reduced appearance of swelling in the DE filter during filtration
  • May be removed from the filter intact without risk of damage or tearing
  • Retention of wet strength even with repeated hot sanitizations
  • Full traceability - Each individual filter sheet is laser etched with the sheet grade, batch number and production date. The packing label includes sheet grade, batch, identification number and a fork and glass symbol.
Seitz PERMAdur S Support Sheets

Product images are a representation of product family for illustration purposes only. Actual products may vary.

Order Products

Gasket / O-Ring Material

Fluorocarbon Elastomer

DFT Classic®, Filter Cartridges, Removal Rating 1 μm, Length 30 Inches, Polypropylene, FluorocarbonElastomer product photo

DFT Classic®, Filter Cartridges, Removal Rating 1 μm, Length 30 Inches, Polypropylene, FluorocarbonElastomer

Product ID: C001AW30UVM3
Unit of Measure
10/EA
Min Order Qty
10
Packaging
Bulk
See All Attributes

Claris® Filter Cartridges, Removal Rating 10 μm, Polypropylene, Length 20 inches, Fluorocarbon Elastomer

Product ID: CLR1020M3V
Unit of Measure
12/EA
Min Order Qty
24
Removal Rating
10 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
20 in
Cartridge Length (Metric)
508 mm
Cartridge Length (Metric)
50.8 cm
Gasket / O-Ring Material
Fluorocarbon Elastomer
See All Attributes

Claris® Filter Cartridges, Removal Rating 20 μm, Polypropylene, Length 30 inches, Fluorocarbon Elastomer

Product ID: CLR2030M3V
Unit of Measure
12/EA
Min Order Qty
12
Removal Rating
20 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
30 in
Cartridge Length (Metric)
762 mm
Cartridge Length (Metric)
76.2 cm
Gasket / O-Ring Material
Fluorocarbon Elastomer
See All Attributes

Claris® Filter Cartridges, Removal Rating 50 μm, Polypropylene, Length 30 inches, Fluorocarbon Elastomer

Product ID: CLR5030M3V
Unit of Measure
24/EA
Min Order Qty
24
Removal Rating
50 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
30 in
Cartridge Length (Metric)
762 mm
Cartridge Length (Metric)
76.2 cm
Gasket / O-Ring Material
Fluorocarbon Elastomer
See All Attributes

Claris® Filter Cartridges, Removal Rating 5 μm, Polypropylene, Length 40 inches, Fluorocarbon Elastomer

Product ID: CLR540M8V
Unit of Measure
12/EA
Min Order Qty
12
Removal Rating
5 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
40 in
Cartridge Length (Metric)
1016 mm
Cartridge Length (Metric)
101.6 cm
Gasket / O-Ring Material
Fluorocarbon Elastomer
See All Attributes

Claris® Filter Cartridges, Removal Rating 75 μm, Polypropylene, Length 30 inches, Fluorocarbon Elastomer

Product ID: CLR7530M3V
Unit of Measure
12/EA
Min Order Qty
12
Removal Rating
75 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
30 in
Cartridge Length (Metric)
762 mm
Cartridge Length (Metric)
76.2 cm
Gasket / O-Ring Material
Fluorocarbon Elastomer
See All Attributes

Claris® Filter Cartridges, Removal Rating 75 μm, Polypropylene, Length 40 inches, Fluorocarbon Elastomer

Product ID: CLR7540M8V
Unit of Measure
12/EA
Min Order Qty
12
Removal Rating
75 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
40 in
Cartridge Length (Metric)
1016 mm
Cartridge Length (Metric)
101.6 cm
Gasket / O-Ring Material
Fluorocarbon Elastomer
See All Attributes
Poly-Fine® II, Filter Cartridges, Removal Rating 0.25 μm, Polypropylene, Length 20 Inches, Fluorocarbon Elastomer, SOE flat closed end external 222 O-rings product photo
Unit of Measure
1/EA
Min Order Qty
1
Micron
0.25 µm
Poly-Fine® II, Filter Cartridges, Removal Rating 0.25 μm, Polypropylene, Length 20 Inches, Fluorocarbon Elastomer, DOE industrial product photo

Poly-Fine® II, Filter Cartridges, Removal Rating 0.25 μm, Polypropylene, Length 20 Inches, Fluorocarbon Elastomer, DOE industrial

Product ID: PFT02520UV
Unit of Measure
1/EA
Min Order Qty
1
Micron
0.25 µm
Poly-Fine® II, Filter Cartridges, Removal Rating 0.25 μm, Polypropylene, Length 30 Inches, Fluorocarbon Elastomer, SOE flat closed end external 222 O-rings product photo
Unit of Measure
1/EA
Min Order Qty
1
Micron
0.25 µm
Poly-Fine® II, Filter Cartridges, Removal Rating 0.25 μm, Polypropylene, Length 30 Inches, Fluorocarbon Elastomer, SOE fin end external 226 O-rings product photo
Unit of Measure
1/EA
Min Order Qty
1
Micron
0.25 µm
Poly-Fine® II, Filter Cartridges, Removal Rating 0.45 μm, Polypropylene, Length 19.5 Inches, Fluorocarbon Elastomer product photo

Poly-Fine® II, Filter Cartridges, Removal Rating 0.45 μm, Polypropylene, Length 19.5 Inches, Fluorocarbon Elastomer

Product ID: PFT045195UVM3
Unit of Measure
1/EA
Min Order Qty
1
Micron
0.45 µm

Documents

Datasheet

  • PERMAdur S Support Filter Sheets

    Select Language :

Instructions for Use

  • Seitz Sheets: Instructions

    Select Language :

Specifications

Food Contact Compliance 

  • Please refer to the Pall website for a Declaration of Compliance to specific National Legislation and/or Regional Regulatory requirements for food contact use.

 

Materials of Construction

  • Main components: Celluloses, Polyolefin fibers
  • Components <3%: Resin

 

Characterization:

  • Mass per unit area g/m2 - 855
  • Thickness mm – 3.5
  • Ash %  < 1
  • Heavy metals* (ppm) < 50
  • Permeability L/m2/min at 1 bar 4370

 

These figures have been determined in accordance with in-house test methods and the methods of the Technical / Analytical Work Group within the European Depth Filtration Association. *According to recommendation XXXVI/1 of the BgW.

 

  • Exctractable ions soluble in 5% acetic acid mg/m2
  • CA 800
  • Fe 5
  • Al 15

 

Quality

Filter sheets produced in a controlled environment. Manufactured according to ISO 9001:2015 certified Quality Management System.

 

Suggested Operating Instructions

Handling during installation 

  1. Place sheet over support plate of the plate and frame filter
  2. For filters with manual tightening device: moisten filter sheets then tighten
  3. For filters with hydraulic tightening device: tighten up to filter pre-pressure of 30-35 bar (432-507 psi). Rinse the filter with warm water at ambient temperature in a forward flow direction with at a flow of at least 50 L/m2
  4. Control and adjust the filter to a pre-pressure of 30-35 bar (432-507 psi) and sterilize

 

Rinsing post filtration 

  1. Flush with water at a temperature of 50-55 °C (122-131 °F)
  2. Flow in the forward direction: should be at least nominal filter output
  3. Counter pressure of 0.5 bar (7.25 psi)
  4. Duration: 10-15 minutes or until the rinse water is clear.

 

Hot water flushing 

  1. Water temperature: >85 °C (185 °F)
  2. Flow in the forward direction: minimal nominal filter output
  3. Counter pressure of 0.5 bar (7.25 psi)
  4. Duration: until a temperature of at least 85 °C (185 °F) is achieved on the outlet side. Allow the filter to stand for at least 30 minutes with hot water. Open the vent valve on the filter inlet side.

 

Steaming 

  1. Steam temperature: max 121 °C (250 °F), low-pressure steam
  2. Duration: 20 minutes