Seitz® PERMAdur® S Support Sheets

Ideal for high performance and longevity 

The Seitz Permadur S Support Sheets afford stable, reusable precoat filtration in plate and frame presses. After filtration, the plate and frame are opened. The filter cake is removed, leaving the Seitz PERMAdur S filter sheet ready for the next run. Made of high-quality cellulose and polyolefin fibers, Seitz PERMAdur S support sheets' production is based on the latest technological and scientific achievements in-depth filter media. Get the support sheets with up to 30 percent longer service life over conventional sheets.  

  • Reduced appearance of swelling in the DE filter during filtration
  • May be removed from the filter intact without risk of damage or tearing
  • Retention of wet strength even with repeated hot sanitizations
  • Full traceability - Each individual filter sheet is laser etched with the sheet grade, batch number and production date. The packing label includes sheet grade, batch, identification number and a fork and glass symbol.
Seitz PERMAdur S Support Sheets

Product images are a representation of product family for illustration purposes only. Actual products may vary.

Order Products

Featured product

false

Filter Media

Polypropylene

NXA 0.5-10U-DOEE product photo

Nexis, NXA, 0.5 μm, 25.4 cm (10 in), DOE with elastomer gasket seals and end caps, EPDM gasket

Product ID: NXA0510UDOEE
Unit of Measure
1/EA
Min Order Qty
1
Micron
0.5 micron
NXA 0.5-10U-M3E product photo

Nexis, NXA, 0.5 μm, 25.4 cm (10 in), SOE flat closed end, external 222 O-rings (retrofits other manufacturers’ Code 0), EPDM gasket

Product ID: NXA0510UM3E
Unit of Measure
60/EA
Min Order Qty
60
Micron
0.5 micron
Nexis® A Series Filter Cartridges, Removal Rating 0.5 μm, Polypropylene, Length 10 inches, Nitrile product photo

Nexis® A Series Filter Cartridges, Removal Rating 0.5 μm, Polypropylene, Length 10 inches, Nitrile

Product ID: NXA0510UM3N
Unit of Measure
30/EA
Min Order Qty
30
Micron
0.5 micron
Nexis® A Series Filter Cartridges, Removal Rating 0.5 μm, Polypropylene, Length 10 inches, silicone product photo

Nexis® A Series Filter Cartridges, Removal Rating 0.5 μm, Polypropylene, Length 10 inches, silicone

Product ID: NXA0510UM3S
Unit of Measure
30/EA
Min Order Qty
30
Micron
0.5 micron

Nexis® A Series Filter Cartridges, Removal Rating 0.5 μm, Polypropylene, Length 10 inches, FEP encapsulated fluorocarbon elastomer Orings

Product ID: NXA0510UM3F
Unit of Measure
30/EA
Min Order Qty
30
Removal Rating
0.5 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
10 in
Cartridge Length (Metric)
254 mm
Cartridge Length (Metric)
25.4 cm
Gasket / O-Ring Material
FEP encapsulated fluorocarbon elastomer (O-rings)
See All Attributes
Nexis® A Series Filter Cartridges, Removal Rating 0.5 μm, Polypropylene, Length 10 inches product photo

Nexis® A Series Filter Cartridges, Removal Rating 0.5 μm, Polypropylene, Length 10 inches

Product ID: NXA0510U
Unit of Measure
30/EA
Min Order Qty
30
Micron
0.5 micron
Nexis® A Series Filter Cartridges, Removal Rating 0.5 μm, Polypropylene, Length 10 inches, EPDM product photo

Nexis® A Series Filter Cartridges, Removal Rating 0.5 μm, Polypropylene, Length 10 inches, EPDM

Product ID: NXA0510UM7E
Unit of Measure
30/EA
Min Order Qty
30
Micron
0.5 micron

Nexis® A Series Filter Cartridges, Removal Rating 0.5 μm, Polypropylene, Length 20 inches, DOE industrial (no end caps)

Product ID: NXA0520U
Unit of Measure
12/EA
Min Order Qty
12
Removal Rating
0.5 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
20 in
Cartridge Length (Metric)
508 mm
Cartridge Length (Metric)
50.8 cm
Gasket / O-Ring Material
NA
See All Attributes
NXA 0.5-10U-M7S product photo

Nexis, NXA, 0.5 μm, 25.4 cm (10 in), SOE fin end, external 226 O-rings (retrofits other manufacturers’ Code 7), Silicone gasket

Product ID: NXA0510UM7S
Unit of Measure
30/EA
Min Order Qty
30
Micron
0.5 micron
NXA 0.5-20U-DOEE product photo

Nexis, NXA, 0.5 μm, 50.8 cm (20 in), DOE with elastomer gasket seals and end caps, EPDM gasket

Product ID: NXA0520UDOEE
Unit of Measure
1/EA
Min Order Qty
1
Micron
0.5 micron

Nexis® A Series Filter Cartridges, Removal Rating 0.5 μm, Polypropylene

Product ID: NXA051UH21
Unit of Measure
6/EA
Min Order Qty
6
Removal Rating
0.5 µm
Membrane Material
Polypropylene
Gasket / O-Ring Material
NA
End Configuration Code
H21
End Configuration
H21 - DOE, Santoprene gasket seal
Cartridge Type
NXA
See All Attributes
Nexis® A Series Filter Cartridges, Removal Rating 0.5 μm, Polypropylene, Length 20 inches, DOE Santoprene gasket seal product photo

Nexis® A Series Filter Cartridges, Removal Rating 0.5 μm, Polypropylene, Length 20 inches, DOE Santoprene gasket seal

Product ID: NXA0520UH21
Unit of Measure
12/EA
Min Order Qty
12
Micron
0.5 micron

Documents

Datasheet

  • PERMAdur S Support Filter Sheets

    Select Language :

Instructions for Use

  • Seitz Sheets: Instructions

    Select Language :

Specifications

Food Contact Compliance 

  • Please refer to the Pall website for a Declaration of Compliance to specific National Legislation and/or Regional Regulatory requirements for food contact use.

 

Materials of Construction

  • Main components: Celluloses, Polyolefin fibers
  • Components <3%: Resin

 

Characterization:

  • Mass per unit area g/m2 - 855
  • Thickness mm – 3.5
  • Ash %  < 1
  • Heavy metals* (ppm) < 50
  • Permeability L/m2/min at 1 bar 4370

 

These figures have been determined in accordance with in-house test methods and the methods of the Technical / Analytical Work Group within the European Depth Filtration Association. *According to recommendation XXXVI/1 of the BgW.

 

  • Exctractable ions soluble in 5% acetic acid mg/m2
  • CA 800
  • Fe 5
  • Al 15

 

Quality

Filter sheets produced in a controlled environment. Manufactured according to ISO 9001:2015 certified Quality Management System.

 

Suggested Operating Instructions

Handling during installation 

  1. Place sheet over support plate of the plate and frame filter
  2. For filters with manual tightening device: moisten filter sheets then tighten
  3. For filters with hydraulic tightening device: tighten up to filter pre-pressure of 30-35 bar (432-507 psi). Rinse the filter with warm water at ambient temperature in a forward flow direction with at a flow of at least 50 L/m2
  4. Control and adjust the filter to a pre-pressure of 30-35 bar (432-507 psi) and sterilize

 

Rinsing post filtration 

  1. Flush with water at a temperature of 50-55 °C (122-131 °F)
  2. Flow in the forward direction: should be at least nominal filter output
  3. Counter pressure of 0.5 bar (7.25 psi)
  4. Duration: 10-15 minutes or until the rinse water is clear.

 

Hot water flushing 

  1. Water temperature: >85 °C (185 °F)
  2. Flow in the forward direction: minimal nominal filter output
  3. Counter pressure of 0.5 bar (7.25 psi)
  4. Duration: until a temperature of at least 85 °C (185 °F) is achieved on the outlet side. Allow the filter to stand for at least 30 minutes with hot water. Open the vent valve on the filter inlet side.

 

Steaming 

  1. Steam temperature: max 121 °C (250 °F), low-pressure steam
  2. Duration: 20 minutes