Performance Characteristics
Cartridge Grade Liquid Service Removal Rating in Microns (µm) at % Efficiency |
Clean Pressure Drop Aqueous Service MBARD / LPM (PSID / GPM) Per 10-inch Element2 |
90% |
99.98% |
020 |
<1.0 |
3.2 |
2.37 / 0.13 |
045 |
1.2 |
4.5 |
1.55 / 0.085 |
060 |
2.5 |
6.0 |
0.64 / 0.035 |
100 |
4.3 |
10.0 |
0.55 / 0.030 |
200 |
11.0 |
20.0 |
0.46 / 0.025 |
300 |
17.0 |
30.0 |
0.36 / 0.020 |
400 |
19.0 |
40.0 |
0.27 / 0.015 |
500 |
25.0 |
50.0 |
<0.18 / 0.010 |
700 |
35.0 |
– 1 |
<0.18 / 0.010 |
1000 |
60.0 |
– 1 |
<0.18 / 0.010 |
Operating Characteristics
Maximum Differential Pressure3 (BARD / PSID) |
Temperature (°C / °F) |
4.1 / 60 |
30 / 86 |
3.4 / 50 |
50 / 122 |
2 / 30 |
70 / 158 |
1 / 15 |
80 / 176 |
1 Precision evaluation of the 99.98% removal efficiency for these coarse grades is not possible with the OSU test procedure utilized.
2 Pressure drop in PSI per GPM for a single 10-inch cartridge. For multiple number of elements, divide by the number of cartridges. For fluids other than water, multiply the value calculated by the fluid's viscosity measured in centipoise.
3 Based upon polypropylene core collapse.