Marksman™ PFT Large Format Filter Cartridges

High Capacity Pleated, All- Polypropylene Filter Cartridges for Consistent Filtration

Marksman PFT large format filter cartridges are constructed from Poly-Fine® II proprietary media for highly consistent filtration. Inside-out flow traps contaminants inside the element while a unique sealing device adjusts to fit most bag filter housings.

Order Products

Element Series

HC2295

Red1000 Glass Fiber 12 micron (Beta 1000) Fluorocarbon 18in 45.72cm

Product ID: HC2295FCS18Z
Unit of Measure
3/EA
Min Order Qty
3
Anti-Static
No
Beta Rating
BETA 1000
Element Series
HC2295
Family
Red1000
Filter Media
Glass Fiber
Filter Removal Rating
12 micron (Beta 1000)
See All Attributes

Ultipor Glass Fiber 7µm Fluorocarbon Seal 14in 35.56cm length

Product ID: HC2295FKN14Z
Unit of Measure
1/EA
Min Order Qty
1
Anti-Static
No
Beta Rating
BETA 1000
Element Series
HC2295
Family
Ultipor
Filter Media
Glass Fiber
Filter Removal Rating (μm)
7 µm
See All Attributes

Ultipor Glass Fiber 5µm Fluorocarbon Seal 18in 45.72cm length

Product ID: HC2295FKP18Z
Unit of Measure
1/EA
Min Order Qty
1
Anti-Static
No
Beta Rating
BETA 1000
Element Series
HC2295
Family
Ultipor
Filter Media
Glass Fiber
Filter Removal Rating (μm)
5 µm
See All Attributes

Supralon™ Lube and Hydraulic Elements, Removal Rating 7 μm, GlassFiber, Length 18 Inches

Product ID: HC2295FRN18Z
Unit of Measure
1/EA
Min Order Qty
1
Anti-Static
Yes
Beta Rating
BETA 2000
Element Series
HC2295
Family
Supralon
Filter Media
Glass Fiber
Filter Removal Rating
7 micron (Beta 2000)
See All Attributes

Supralon™ Lube and Hydraulic Elements, Removal Rating 7 μm, GlassFiber, Length 14 Inches

Product ID: HC2295FRN14Z
Unit of Measure
6/EA
Min Order Qty
6
Anti-Static
Yes
Beta Rating
BETA 2000
Element Series
HC2295
Family
Supralon
Filter Media
Glass Fiber
Filter Removal Rating
7 micron (Beta 2000)
See All Attributes

Supralon™ Lube and Hydraulic Elements, Removal Rating 5 μm, GlassFiber, Length 14 Inches

Product ID: HC2295FRP14Z
Unit of Measure
6/EA
Min Order Qty
6
Anti-Static
Yes
Beta Rating
BETA 2000
Element Series
HC2295
Family
Supralon
Filter Media
Glass Fiber
Filter Removal Rating
5 micron (Beta 2000)
See All Attributes

Supralon™ Lube and Hydraulic Elements, Removal Rating 25 μm, GlassFiber, Length 36 Inches

Product ID: HC2295FRT36HY
Unit of Measure
1/EA
Min Order Qty
1
Anti-Static
Yes
Beta Rating
BETA 2000
Element Series
HC2295
Family
Supralon
Filter Media
Glass Fiber
Filter Removal Rating
25 micron (Beta 2000)
See All Attributes

Supralon™ Lube and Hydraulic Elements, Removal Rating 5 μm, GlassFiber, Length 36 Inches

Product ID: HC2295FRP36Z
Unit of Measure
1/EA
Min Order Qty
1
Anti-Static
Yes
Beta Rating
BETA 2000
Element Series
HC2295
Family
Supralon
Filter Media
Glass Fiber
Filter Removal Rating
5 micron (Beta 2000)
See All Attributes

Supralon™ Lube and Hydraulic Elements, Removal Rating 7 μm, GlassFiber, Length 36 Inches

Product ID: HC2295FRN36Z
Unit of Measure
1/EA
Min Order Qty
1
Anti-Static
Yes
Beta Rating
BETA 2000
Element Series
HC2295
Family
Supralon
Filter Media
Glass Fiber
Filter Removal Rating
7 micron (Beta 2000)
See All Attributes

Supralon™ Lube and Hydraulic Elements, Removal Rating 5 μm, GlassFiber, Length 18 Inches

Product ID: HC2295FRP18Z
Unit of Measure
3/EA
Min Order Qty
3
Anti-Static
Yes
Beta Rating
BETA 2000
Element Series
HC2295
Family
Supralon
Filter Media
Glass Fiber
Filter Removal Rating
5 micron (Beta 2000)
See All Attributes

Supralon™ Lube and Hydraulic Elements, Removal Rating 12 μm, GlassFiber, Length 14 Inches

Product ID: HC2295FRS14Z
Unit of Measure
6/EA
Min Order Qty
6
Anti-Static
Yes
Beta Rating
BETA 2000
Element Series
HC2295
Family
Supralon
Filter Media
Glass Fiber
Filter Removal Rating
12 micron (Beta 2000)
See All Attributes

Supralon™ Lube and Hydraulic Elements, Removal Rating 7 μm, GlassFiber, Length 36 Inches

Product ID: HC2295FRN36HY
Unit of Measure
1/EA
Min Order Qty
1
Anti-Static
Yes
Beta Rating
BETA 2000
Element Series
HC2295
Family
Supralon
Filter Media
Glass Fiber
Filter Removal Rating
7 micron (Beta 2000)
See All Attributes

Description

Why choose Marksman large format filter cartridges? 

They are available to fit most Size 1 and Size 2 bag housings with no hardware changes.  

 

Additional benefits include:

  • High surface area for long service life
  • Wide chemical compatibility
  • Short length option to accommodate smaller baskets

Applications/Use

Chemicals and Polymer

  • Chemicals – Final product (liquid), raw material (gas, air, liquid) and intermediate product – other
  • Petrochemicals – Amine, Benfield and other solvent loops
  • Polymer – Carbon fiber, nylon and polyurethane production

Food and Beverage

  • Beer (Corporate) – Incoming water
  • Craft Microbreweries – Incoming water

Oil and Gas

  • Upstream – Injection water and SRU
  • Midstream – LNG acid gas, acid gas, glycol filtration and process water
  • Refinery – Amine systems

Industrial Manufacturing

  • Automotive – Filling lines/stations
  • Primary metals – Coolants/bearing lubricants, drive gearbox + roll housing, forging extrusion, gearbox/bearing, gearbox/morgoil, material directional control, material handling, noncontact, quenching/cleaning, roll bite – safety filter and shape + material handling

Specifications

*Please refer to the documentation for additional specifications.

 

Performance Specifications

 

Filter grades

 

1, 3, 5, 10, 20, 40, 70, 90, 150 micron (µm)

 

Maximum operating differential pressure

 

to 5.2 bard @ 20°C (75 psid @ 68°F)

to 2.4 bard @ 74°C (35 psid @ 165°F)

 

NOTE: Stainless steel flange recommended for temperatures in excess of 43°C (110°F).

 

Recommended change-out differential pressure1

 

2.4 bard @ up to 54°C (35 psid @ up to 130°F)

 

Food and water contact use

 

Please contact Pall Corporation to verify that the product conforms to your national legislation and/or regional regulatory requirements for water and food contact use.

 

Purity

 

Cartridges do not use surfactants, binders, and adhesives.

 

Sanitization

Contact Pall Corporation for assistance.

 

1Provided that the maximum differential pressure is not exceeded based on temperature limits defined above.

Documents

Data Sheets

  • Marksman PFT Series Filter Elements