Marksman™ PFT Large Format Filter Cartridges

High Capacity Pleated, All- Polypropylene Filter Cartridges for Consistent Filtration

Marksman PFT large format filter cartridges are constructed from Poly-Fine® II proprietary media for highly consistent filtration. Inside-out flow traps contaminants inside the element while a unique sealing device adjusts to fit most bag filter housings.

Order Products

Gasket / O-Ring Material

FEP encapsulated fluorocarbon elastomer (O-rings)

Duo-Fine® , Filter Cartridges, Removal Rating 30 μm, Length 10 Inches, FEP encapsulated fluorocarbon elastomer Orings, Blank - DOE with elastomer gasket seals & end caps

Product ID: DFN3010AT
Unit of Measure
30/EA
Min Order Qty
30
Removal Rating
30 µm
Cartridge Length (Imperial)
10 in
Cartridge Length (Metric)
254 mm
Cartridge Length (Metric)
25.4 cm
Gasket / O-Ring Material
FEP encapsulated fluorocarbon elastomer (O-rings)
End Configuration
Blank - DOE with elastomer gasket seals & end caps
See All Attributes

Nexis® A Series Filter Cartridges, Removal Rating 0.5 μm, Polypropylene, Length 10 inches, FEP encapsulated fluorocarbon elastomer Orings

Product ID: NXA0510UM3F
Unit of Measure
30/EA
Min Order Qty
30
Removal Rating
0.5 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
10 in
Cartridge Length (Metric)
254 mm
Cartridge Length (Metric)
25.4 cm
Gasket / O-Ring Material
FEP encapsulated fluorocarbon elastomer (O-rings)
See All Attributes
Nexis® A Series Filter Cartridges, Removal Rating 20 μm, Polypropylene, Length 30 inches, FEP encapsulated fluorocarbon elastomer Orings product photo

Nexis® A Series Filter Cartridges, Removal Rating 20 μm, Polypropylene, Length 30 inches, FEP encapsulated fluorocarbon elastomer Orings

Product ID: NXA2030UM8F
Unit of Measure
12/EA
Min Order Qty
12
Micron
20 micron

Nexis® A Series Filter Cartridges, Removal Rating 5 μm, Polypropylene, Length 20 inches, FEP encapsulated fluorocarbon elastomer Orings

Product ID: NXA520UM7F
Unit of Measure
24/EA
Min Order Qty
24
Removal Rating
5 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
20 in
Cartridge Length (Metric)
508 mm
Cartridge Length (Metric)
50.8 cm
Gasket / O-Ring Material
FEP encapsulated fluorocarbon elastomer (O-rings)
See All Attributes
Nexis® T Filter Cartridges, Removal Rating 0.5 μm, Polypropylene, Length 30 inches, FEP encapsulated Fluorocarbon Elastomer Orings product photo

Nexis® T Filter Cartridges, Removal Rating 0.5 μm, Polypropylene, Length 30 inches, FEP encapsulated Fluorocarbon Elastomer Orings

Product ID: NXT0530UM26F
Unit of Measure
24/EA
Min Order Qty
24
Micron
0.5 micron

Nexis® T Filter Cartridges, Removal Rating 100 μm, Polypropylene, Length 10 inches, FEP encapsulated Fluorocarbon Elastomer Orings, SOE flat closed end external 222 O-rings

Product ID: NXT10010UM3F
Unit of Measure
30/EA
Min Order Qty
60
Removal Rating
100 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
10 in
Cartridge Length (Metric)
254 mm
Cartridge Length (Metric)
25.4 cm
Gasket / O-Ring Material
FEP encapsulated fluorocarbon elastomer (O-rings)
See All Attributes
Nexis® T Filter Cartridges, Removal Rating 100 μm, Polypropylene, Length 27.25 inches product photo

Nexis® T Filter Cartridges, Removal Rating 100 μm, Polypropylene, Length 27.25 inches

Product ID: NXT1002725UM18F
Unit of Measure
12/EA
Min Order Qty
12
Micron
100 micron
Nexis® T Filter Cartridges, Removal Rating 10 μm, Polypropylene, Length 16.25 inches product photo

Nexis® T Filter Cartridges, Removal Rating 10 μm, Polypropylene, Length 16.25 inches

Product ID: NXT101625UM3F
Unit of Measure
24/EA
Min Order Qty
24
Micron
10 micron
Nexis® T Filter Cartridges, Removal Rating 10 μm, Polypropylene, Length 20 inches, FEP encapsulated Fluorocarbon Elastomer Orings, SOE flat closed end external 222 O-rings product photo
Unit of Measure
12/EA
Min Order Qty
12
Micron
10 micron
Nexis® T Filter Cartridges, Removal Rating 150 μm, Polypropylene, Length 10 inches, FEP encapsulated Fluorocarbon Elastomer Orings, M18 - SOE flat closed end, external 222 O-ring product photo
Unit of Measure
30/EA
Min Order Qty
30
Micron
150 micron
Nexis® T Filter Cartridges, Removal Rating 150 μm, Polypropylene, Length 27.25 inches product photo

Nexis® T Filter Cartridges, Removal Rating 150 μm, Polypropylene, Length 27.25 inches

Product ID: NXT1502725UM18F
Unit of Measure
12/EA
Min Order Qty
12
Micron
150 micron
Nexis® T Filter Cartridges, Removal Rating 150 μm, Polypropylene, Length 16.25 inches product photo

Nexis® T Filter Cartridges, Removal Rating 150 μm, Polypropylene, Length 16.25 inches

Product ID: NXT1501625UM3F
Unit of Measure
12/EA
Min Order Qty
12
Micron
150 micron

Description

Why choose Marksman large format filter cartridges? 

They are available to fit most Size 1 and Size 2 bag housings with no hardware changes.  

 

Additional benefits include:

  • High surface area for long service life
  • Wide chemical compatibility
  • Short length option to accommodate smaller baskets

Applications/Use

Chemicals and Polymer

  • Chemicals – Final product (liquid), raw material (gas, air, liquid) and intermediate product – other
  • Petrochemicals – Amine, Benfield and other solvent loops
  • Polymer – Carbon fiber, nylon and polyurethane production

Food and Beverage

  • Beer (Corporate) – Incoming water
  • Craft Microbreweries – Incoming water

Oil and Gas

  • Upstream – Injection water and SRU
  • Midstream – LNG acid gas, acid gas, glycol filtration and process water
  • Refinery – Amine systems

Industrial Manufacturing

  • Automotive – Filling lines/stations
  • Primary metals – Coolants/bearing lubricants, drive gearbox + roll housing, forging extrusion, gearbox/bearing, gearbox/morgoil, material directional control, material handling, noncontact, quenching/cleaning, roll bite – safety filter and shape + material handling

Specifications

*Please refer to the documentation for additional specifications.

 

Performance Specifications

 

Filter grades

 

1, 3, 5, 10, 20, 40, 70, 90, 150 micron (µm)

 

Maximum operating differential pressure

 

to 5.2 bard @ 20°C (75 psid @ 68°F)

to 2.4 bard @ 74°C (35 psid @ 165°F)

 

NOTE: Stainless steel flange recommended for temperatures in excess of 43°C (110°F).

 

Recommended change-out differential pressure1

 

2.4 bard @ up to 54°C (35 psid @ up to 130°F)

 

Food and water contact use

 

Please contact Pall Corporation to verify that the product conforms to your national legislation and/or regional regulatory requirements for water and food contact use.

 

Purity

 

Cartridges do not use surfactants, binders, and adhesives.

 

Sanitization

Contact Pall Corporation for assistance.

 

1Provided that the maximum differential pressure is not exceeded based on temperature limits defined above.

Documents

Data Sheets

  • Marksman PFT Series Filter Elements

    Select Language :